DO NOT SCALE THIS DRAWING

A 2mm thick PPC aluminum


trim RAL TBC 95
DISCLAIMER
This drawing is the property of Advanced Roofing Ltd and is issued
on the condition it is not reproduced, retained or disclosed to any
unauthorized person, either wholly or in part without the written
consent of Advanced Roofing Ltd.

15
° 30
87 This drawing should be read in conjunction

100
2mm galv Z angle  SITE MEASURE with all relevant design drawings,

25
PRE-FABRICATION
30 calculations and system manufacturers
2mm thick PPC aluminum 260 instructions.
trim RAL TBC Deviation from the design is not permitted.
150x100mm 0.7mm galv
angle
Any discrepancies are to be notified to
Advanced Roofing Design

20
2mm thick glav z angle 2mm galv Z angle

93
Dept. immediately.

°
Mineral wool infill
300
112.097 insulation

LEGEND

112.025
TOS
112.015

NOTES

DRAWING STATUS

FOR APPROVAL
Top/S F.M. base sheet torch on
underlay and Paralon ARD/S torch on
mineral cap sheet (refer to specification
for details)
Parotherm G tissue faced PIR insulation
board (100mm) and Paratherm T PIR
insulation board (100mm) P01 First Issue 04.11.22 KM
Revision Description Date Initials
D32S profile decking to form upstand,
fixed to galv angles top and bottom

60mm thick mineral wool upstand


insulation board

150 x 100mm 0.7mm galv angle


Advanced House
Littlewell Lane
Stanton by Dale
Derbyshire
DE7 4QW

E: info@advanced-roofing.co.uk
T: 0115 944 5555 F: 0115 944 4567

Project

Southam College

Package

Roofing works

Vapobar 1 AL/VV aluminum lined


Title
torch on vapour barrier
Parapet detail level 3
Detail G

Cad File Name Drawn By Approved Checked

- KM - -
Date Scale Size

04.11.22 1:6 A3
Parapet Detail Level 3 Name Parapet detail level 3
Detail G Drawing No 1439055-ARL-AA-03-DR-Y-0003
Revision P01
Status Preliminary