Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GX TOUCH 50 VE.

Direct from MPPT


VE.Direct from BMV
VE.Bus from MultiPlus
ETHERNET

VE-BUS MAINS DETECTOR SMART MPPT PV ARRAY PV BREAKER ORION-Tr SMART


VE.Bus BMS GX TOUCH 50 CERBO GX HDMI
ISOLATOR
victron energy victron energy
BLUE POWER BLUE POWER

AC Input

0W
Inverting
victron energy
AC Loads

102W
VRM
WORLD
SmartSolar charge controller Orion-Tr Smart
The VE-BUS BMS is enlarged MPPT 100 | 30 12 I 12 - 30
visible in this drawing. Non-isolated DC/DC charger
The BMS GND is not connected
to prevent ground loops. name

Ground comes through the - + PV-Charger


victron energy ! i IP43 i IP43
VE.Bus UTP cable. 75% 300W Battery 12/24V 30A 0 OFF 0 OFF Input I 8-17V
Output I 10-15V

Absorbtion
PV 100Vmax 30A Power I 360W (30A)
103W
DC Power

Float
12.8V 8.1A -90W

Bulk
on/off
victron energy
BATTERY PV IN GND OUT

+ - - + + - +
SMART BATTERY PROTECT 220 L H

VE-direct
BMS ON/OFF
MAIN
BMS POWER+
SWITCH-1
BMS LOAD DISCONNECT
BMS CHARGE DISCONNECT CERBO Power -
ORION H-CONTACT
ON CERBO Power +
Pre-Alarm Buzzer D
TE

EC
OT
PR
12 VOLT 30mA

N
OF F I G N I T I O
OFF
VE-BUS MAINS DETECTOR VE.Bus to Cerbo
BTV CABLE

BTV CABLE

PRE-ALARM + HOUSE

G TO
VE.Direct to Cerbo

HIN
ov e

I TC
m
Re

SW
R

E
FO
BE
G I NE
S T OP E N

M8 CIRCULAR CONNECTORS

SBP100-H

MAIN FUSE ORION INPUT

PRE-ALARM & SBP220-


DC-DISTRIBUTION
Starter Battery

THERMAL CIRCUIT BREAKER


MAIN DC DISTRIBUTION SBP100 GND -
BMV-B2 / 100mA FUSE
MAIN SWITCH-3

60 AMPERE
POSITIVE

285060F
POSITIVE

A
B
T
Charger Starter Battery 3A FUSE

D
A
L
BUSBAR BUSBAR ON
D T
SE
TE

EC
RE

OT
PR
ANL MEGA

N
Load+

OF F I G N I T I O
victron energy
xxxA

BLUE POWER
12V-100Ah

OFF
PROG

100A GND
ENGINE

G TO
ALARM

Starter Battery

HIN
ve
MEGA

mo

I TC
L
REMOTE
Load+

Re

SW
H
xxxA R

E
FO
BE
ANL I NE
S TOP EN
G 1
FUSE

Smart Battery Protect


A
IGNITION

IN
50

12/24 | 100
150A MEGA
Load+ FUSE
KEEP POSITIVE BATTERY CABLES xxxA
xx AMP.
ALL AT THE SAME LENGTH ! ANL
30 FROM STARTER+(30) 30 15

THERMAL CIRCUIT BREAKER


OUT
Smart

40 AMPERE
175A

285040F
A
B
T
Charge light

D
A
L
Battery STARTER
SE
T MPPT+ MOTOR
ANL Protect 100 RE

MULTIPLUS 1600VA/12V DC/230V AC INVERTER/CHARGER 31 ENGINE SYSTEM

THERMAL CIRCUIT BREAKER


175A

MAIN SWITCH-2

60 AMPERE
285060F
A
B
T

D
A
L
BMS 2A
ON
BMV 100mA D
TE SE
T Orion+ INTERNAL
RE

EC
ALTERNATOR
OT
PR
CERBO 1A

N
FUSE
OF F I G N I T I O
5x20mm victron energy
OFF

MEGA
MultiPlus Batt +
BLUE POWER
FUSES 175A AMI
MultiPlus
100A
G TO
HIN
ve
mo

I TC
Re

SW

RE
FO
BE
G I NE
S T OP E N
MultiPlus
BMV-712 SMART 12 | 1600 | 70 230V SHORE POWER
BTV CABLE CERBO POWER +
www.victronenergy.com

IP21
CONNECTION
BMV-712 SMART
!
BTV CABLE BMV POWER + BATTERY MONITOR
victron energy
BLUE POWER
i
B- D+ B+
MAIN V

VE.Direct
M8 CIRCULAR CENTRAL NEGATIVE BUSBAR SETUP SELECT
victron energy
CONNECTORS BLUE POWER

SBP100- ALTERNATOR SHORE POWER

SBP220-
12V-80A ISOLATION TRANSFORMER OR
SUPPLIED UTP CABLE
GALVANIC ISOLATOR SHOULD BE
CERBO- INSERTED HERE IF NEEDED,
INCLUDING NECESSARY
Load- BREAKERS.

MPPT-
Load-

2 x Lithium
12.8V-100Ah

12.8V-100Ah
Smart LiFePO4

Smart LiFePO4
Lithium

Lithium

Load- AC DISTRIBUTION

12.8V-100Ah
victron energy

victron energy

Load-
BLUE POWER

BLUE POWER

Smart LiFePO4 Starter Battery-


1 N 1 N

name name name name name name


Inverter ADxxxxx xxA/I n0.03A ADxxxxx xxA/I n0.03A

Multiplus Case GR T T

victron energy
Bx test regularly Bx test regularly
Charger

BLUE POWER
0 0

Mains detector
0 OFF 0 OFF 0 OFF 0 OFF

VE.Bus BMS
Alarm

Multiplus Batt- earth fault indicator earth fault indicator

MCB/RCD MCB/RCD

2 N 2 N

MultiPlus Output MULTIPLUS


+B2 Starter Battery +
+B1 MultiPlus Input OUTPUT
VE.Bus Cerbo Conn-C to VE.Bus mains detector
VE.Bus BMS VE.Bus BMS
THE BMV SHUNT IS MOUNTED
DIRECT ON BOTH BUSBARS Conn-G Start Batt+ No Break load-1
KEEP NEGATIVE BATTERY CABLES No Break load-2
ALL AT THE SAME LENGTH ! Drawing BJE-260A Conn-K Batt+
MultiPlus input
Conn-L Case ground Small Geyser
Conn-F Batt- VE.Bus mains detector VE-Bus Mains detector is
VE.Bus BMS inside AC distribution box

Recommended AC Out cable/breaker size MultiPlus Recommended DC cable/fuse size MultiPlus Recommended AC In cable/breaker size MultiPlus WARNING
With Power assist the MultiPlus can add 0-5 m cable length: 50SQmm AC IN must be protected by a circuit 230 VOLT IS EXTREMELY HAZARDOUS
1.3 KW to the output load when needed. Cable length stands for the total distance between breaker rated at 16A max or less. DO NOT TOUCH ANY LIVE WIRED
Together with the adjustable 16A input this the battery connections plus and minus and the This depends heavily on the size of the PARTS OF THE INSTALLATION !
all adds up to the max sum of input and MultiPlus connections ! Recommendations are connected power source.The input current WHEN IN DOUBT, ALWAYS CONSULT
output current of 16+5.6=21.6A. An Earth without other loads in the system and these also must be adjusted to fit the size of the YOUR VICTRON DEALER !
leakage with breaker or a combination should be taken into account for proper main connected power source.
MCB/RCD must be installed on the output. battery, main fuse & main switch cables ! The breaker and cable size for AC IN
Cable size must be adjusted accordingly. INTERNAL Fuse size should be 200A. should be adjusted accordingly.

You might also like