SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Pre-Engineered Building Components/ Material Receiving,


SAIC-M-1031 15-Nov-17 CIVIL-
Handling & Storage Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A Receiving Inspection

The Final Inspection Shipping release is available along with the Pre-
Schedule Q,
Engineered Building at the time of receipt at the job site. (Note: Pre-
A1 Attach III, Sec.
Engineering Building is Inspection Level 3 as per SAEP-1151, Appendix
3.23
A)

The materials furnished shall include the roofing, siding, anchor bolts,
flashing and trim, leveling plates, doors, windows, hardware, fasteners, 12-SAMSS-014
A2
sealants, and any other component parts for the metal buildings as Sec. 4.1
specified in the order and as required to make a complete system.

All materials shall be new, free of defects and meet or exceed the physical 12-SAMSS-014
A3
requirements of the design and fabrication process. Sec. 6

Unless indicated in the Purchase Order, the vendor shall provide either
single sheet or sandwich type roof and wall panels based on the required
12-SAMSS-014
A4 maximum heat transmission coefficient and required internal design
Sec. 6.5
temperature. The choice of panels is subject to prior written approval of
the buyer.

12-SAMSS-014
A5 Roof panels shall be ribbed to provide adequate rigidity.
Sec. 6.5.1.b

Single Sheet Roof and Wall Panels shall be made of a minimum 0.5 mm
12-SAMSS-014
(26 gage) thick galvanized or aluminum-zinc alloy-coated steel sheet.
A6 Sec. 6.5.1.a &
Roof panels for buildings in coastal areas, or as specified in the purchase
Sec. 6.5.3.b
order shall be made of a minimum 0.7 mm thickness aluminum sheet.

Single Sheet Roof and Walls Panels shall be insulated to provide the 12-SAMSS-014
A7 maximum heat transmission coefficient (U) as specified in the Purchase Sec. 6.5.1.g &
Order. Sec. 6.5.3.f

Fiberglass insulation shall meet the following conditions: flexible; resilient;


odorless; shall not contribute to corrosion of steel or aluminum; flame
spread rating of 25 or less and shall comply with the provisions of Section
707 of the Uniform Building Code; facing shall cover the width of the 12-SAMSS-014
A8
fiberglass blanket plus two flanges each 50 mm wide; vapor barrier to be Sec. 6.5.1.h
aluminum foil or equal placed on the outside. Interior exposed insulation
shall receive a quilted covering (preferably a fiberglass scrim) on the
interior surface to protect the insulation.

Sandwich Roof/ Wall Panels shall be self contained, factory assembled 12-SAMSS-014
A9 foam plastic insulated units having a nominal covering width of not less Sec. 6.5.2.a &
than 900 mm (3 ft nominal) unless approved otherwise by Saudi Aramco. Sec. 6.5.4.a

Saudi Aramco: Company General Use


SAUDI ARAMCO ID/PIEU - 15-Nov-2017 - REV. 2016.06.00 (Standards Cutoff -June 30, 2016) Rev. 2016.06.00 30-Jun-16

SAUDI ARAMCO INSPECTION CHECKLIST SAIC NUMBER DATE APPROVED QR NUMBER

Pre-Engineered Building Components/ Material Receiving,


SAIC-M-1031 15-Nov-17 CIVIL-
Handling & Storage Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Sandwich Roof/ Wall Panels exterior face sheet shall be made of


minimum 0.5 mm (26 gage) thick galvanized or aluminum-zinc alloy-
12-SAMSS-014
coated sheet steel and shall be formed architecturally to provide adequate
A10 Sec. 6.5.2.b &
rigidity. For buildings in coastal areas, or as specified in the purchase
Sec. 6.5.4.b
order the external face sheet shall be made of a minimum 0.7 mm
thickness aluminum sheet.

Sandwich Roof/ Wall Panels interior face sheet shall be minimum 0.5 mm 12-SAMSS-014
A11 (26 gage) thick galvanized or aluminum-zinc alloy-coated sheet steel and Sec. 6.5.2.c &
shall be formed into a plane surface. Sec. 6.5.4.c

12-SAMSS-014
Sandwich Roof/ Wall Panels Foam plastic insulation shall have a flame
A12 Sec. 6.5.2.d &
spread rating of 25 or less.
Sec. 6.5.4.f

Roof and Wall Fasteners shall be hex head carbon steel screws
assembled with an EPDM washer and mechanically zinc coating in
12-SAMSS-014
A13 accordance with ASTM B695, Class 50. However, in coastal areas an
Sec. 6.6
austenitic (300 series) stainless steel fasteners shall be used. Fastener
heads shall be coated the same color as the panels.

Sealant shall have sufficient adhesion to metal and plastic so as to remain


12-SAMSS-014
A14 in place during normal handling operations. Adhesive tensile strength
Sec. 6.7.1.c
shall be a minimum of 28 kPa (4 psi).

Galvanized or aluminum-zinc steel for flashing, metal closures, trim and


12-SAMSS-014
A15 other miscellaneous uses shall be 0.5 mm (26 gage) conforming to Item
Sec. 6.7.2.c
A.11.

B Handling & Storage Inspection

Sandwich panels shall be in banded stacks with suitable foam or


cardboard separators between each panel to prevent damage to the
12-SAMSS-014
B.1 finished paint surfaces. The bands shall also be prevented from damaging
Sec. 12.2
the panels. Structural steel members shall be suitably separated by timber
or similar during transport and storage.

REMARKS:

REFERENCE DOCUMENTS:
1- 12-SAMSS-014 -- Pre-Engineered Metal Buildings, 16 Jan. 2014

Saudi Aramco: Company General Use


Contractor / Third-Party Saudi Aramco
Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED