Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

LOGIQ P7

Make it easy. Make it your own.

Product description
The LOGIQ™ P7 is a highly capable ultrasound system
that provides excellent image quality and productivity
through easy to use tools across a wide range of
applications in a portable, ergonomic, budget-friendly
system design.
General specifications System overview
Dimensions and weight: Applications:
Height Fixed Monitor Arm (Standard) Abdominal
LOGIQ P7 Std: 1375 mm Obstetrical
(54.1 in)
Gynecological
LOGIQ P7 Tall: 1475 mm
(60.0 in) Articulating Breast
Monitor Arm (option) Small Parts and Superficial
LOGIQ P7 Std 1320 mm ~ Musculoskeletal
1470 mm (52.0 in ~ 57.9 in)
Endocavitary (Transvaginal, Transrectal)
LOGIQ P7 Tall 1420 mm ~
1570 mm (55.9 in ~ 61.8 in) Vascular
Width Keyboard: 430 mm (16.9 in) Urological
Foot Cover: 495 mm (19.5 in) Pediatric & Neonatal
Monitor: 525 mm (20.7 in Intraoperative
Depth Foot Cover: 685 mm (27.0 in) Cardiac
Rear Handle: 740 mm (29.1 in) Transcranial
Weight (no Peripherals) 60 kg/132 lbs
Scanning methods:
Electrical power
(Power consumption maximum of 500 VA with peripherals) Electronic Sector
Electronic Convex
Voltage 100 – 240 Vac
Electronic Micro Convex
Frequency 50/60 Hz
Electronic Linear
Console design: Real Time 4D Volume Sweep
3 active probe ports
Probe types:
4 active probe ports (option)
Sector Phased Array
Integrated HDD and DVD±R/W
Convex Array
On board storage for BW printer
Microconvex Array
Integrated speakers
Linear Array
Probe holders
Single CW (Pencil) Probes
Front handle
Volume Probes (4D)
Gel Warmer (option)
Rear handle (option) Operating modes:
B-Mode
User interface
Coded Harmonic Imaging
Operator keyboard
M-Mode
Ergonomic full size keyboard
Color Flow Mode (CFM)
Digital TGC and Digital A/N keyboard
Power Doppler Imaging (PDI)
Physical A/N keyboard (option)
PW Doppler with High PRF
10.4" LCD touch screen M-Color Flow Mode
Anatomical M-Mode
Monitor
Curved Anatomical M-Mode
21.5" wide screen LCD with high resolution
B-Flow™/B-Flow color (option)
Articulating monitor arm (option)
Extended Field of View (LOGIQ View option)
Coded Contrast Imaging (option)
CW Doppler Mode (option)
TVI Mode (option)
Elastography (option)
3D/4D Volume Modes (option)
System overview (cont.)
System standard features
Advanced user interface with high resolution 10.4" wide AutoEF
LCD touch screen B Steer+
Automatic Optimization Stress Echo
CrossXBeam™ compounding Tissue Velocity Imaging (TVI) with Q-Analysis
Speckle Reduction Imaging (SRI-HD) Scan Assistant
Fine Angle Steering Compare Assistant
Coded Harmonic Imaging Report Writer
Virtual Convex ECG + AHA/IEC Cables
Advanced 3D (option) CW Doppler
Patient information Database Software DVR
Image Archive on integrated CD/DVD and hard drive • Storage: CD/DVD Media
Raw Data Analysis • Storage: USB Memory Stick
Real-time automatic Doppler calculations Real Time 4D
OB Calculations 4D TUI
Fetal Trending VOCAL
Multigestational Calculations VCI Static
Hip Dysplasia Calculations Measure Assist Breast
Gynecological Calculations Cabinet: High/Low
Vascular Calculations Drawer
Urological Calculations Small Probe Adaptor
Renal Calculations Side Tray
Cardiac Calculations Probe Cable Hanger
Remote capability: InSite™ ExC Paper Tray
On-board electronic documentation OPIO Tray
MPEGVue Rear handle
Key Macro Gel warmer
Network Storage Multipurpose holder
Quick Save Physical A/N keyboard
Quick Patient Entry
TIC Motion Tracking Peripheral options
My Page Integrated Options for:
My Trainer • Digital BW thermal printer
• Digital Color thermal printer
System options External USB printer connection
Auto IMT Wireless LAN card for wireless data transfer
Advanced 3D HDMI output available for compatible devices
Cable hook rear Foot Switch with programmable functionality
Card Reader Mounting Kit Console Protective Cover
Elastography Universal Video Converter
Elastography Quantification1 Power Assistant (Battery Pack)
DICOM® 3.0 Connectivity
Display modes
LOGIQ View
Live and Stored Display Format: full size and split screen –
B-Flow/B-Flow color
both with thumbnails for still and Cine
CF/PDI Quantification (FlowQA)
Review Image Format: 4x4 and “thumbnails” for still and Cine
Breast Productivity Package
Simultaneous Capability
Thyroid Productivity Package
B or CrossXBeam/PW
Measure Assist OB
B or CrossXBeam/CFM or PDI
System overview (cont.)
Display modes (cont.)
B/M Focal Zone Markers
B/CrossXBeam Image Depth
Real-time Triplex Mode (B or CrossXBeam + CFM or PDI/PW Zoom Depth
or CW (option) B-Mode
Selectable alternating Modes Gain
B or CrossXBeam/PW Dynamic Range
B or CrossXBeam + CFM (PDI)/PW (CW)(option) Imaging Frequency
B/CW (option) Frame Averaging
Multi-image (split/quad screen) Acoustic Frame Rate
Live and/or frozen Gray Map
B or CrossXBeam + B or CrossXBeam/CFM or PDI SRI-HD
Independent Cine playback M-Mode
Time line display Gain
Independent Dual B or CrossXBeam/PW Display Dynamic Range
CW Time Scale
Display Formats Doppler Mode
• Top/Bottom selectable format
Gain
• Side/Side selectable format
Angle
Virtual Convex
Sample Volume Depth and Width
Timeline only
Wall Filter
Display annotation Velocity and/or Frequency Scale
Spectrum Inversion
 atient Name: First, Last and Middle
P
Time Scale
Patient ID
PRF
2nd Patient ID
Doppler Frequency
Age, Sex and Birth Date
Color Flow Mode
Hospital Name
Line Density
Date format: 3 types selectable
• MM/DD/YY Frame Averaging
• DD/MM/YY Packet Size
• YY/MM/DD Color Scale: 3 types
T ime format: 2 types selectable • Power • Symmetrical Velocity
• 24 hours • Directional PDI Imaging
• 12 hours Color Velocity Range and Baseline
Gestational Age from Color Threshold Marker
•LMP • EDD Color Gain
• GA • BBT
PDI
Displayed Acoustic Output
Inversion
TIS: Thermal Index Soft Tissue
Doppler Frequency
TIC: Thermal Index Cranial (Bone)
TGC Curve
TIB: Thermal Index Bone
Cine Gage, Image Number/Frame Number
MI: Mechanical Index
Body Pattern: Multiple human and animal types
% of Maximum Power output
Probe Name Application Name
Map Names Measurement Results
Probe Orientation Operator Message
Depth Scale Marker Biopsy Guide Line and Zone
Lateral Scale Marker Heart Rate
General system parameters
System setup
Pre-programmable Categories Wireless LAN (option)
User Programmable Preset Capability Verify
Factory Default Preset Data Print
Languages: English, French, German, Spanish, Italian, Store
Portuguese, Russian, Greek, Swedish, Danish, Dutch, Finnish,
Modality Worklist
Norwegian, Japanese (message only)
Storage Commitment
OB Report Formats including Tokyo Univ., Osaka Univ., USA,
Europe, and ASUM Modality Performed Procedure Step (MPPS)
User Defined Annotations Media Exchange
Body Patterns Off network/mobile storage queue
Customized Comment Home Position Query/Retrieve
Public SR Template
Reset
• Structured Reporting – compatible with vascular and OB
standard
Complete user manual available on-board through help (F1)
• Direct Export DICOM SR and XML
User Manual and Service Manual are included on a CD with
Remote capability InSite ExC
each system. A printed manual is available upon request.
Physiological input panel (option)
CINE memory/image memory
Physiological Input
776 MB of Cine Memory
ECG, 2 lead
Selectable Cine Sequence for Cine Review
Dual R-Trigger
Prospective Cine Mark
Pre-settable ECG R Delay Time
Measurements/Calculations and Annotations on Cine
Playback Pre-settable ECG Position
Scrolling timeline memory Adjustable ECG Gain Control
Dual Image Cine Display Automatic Heart Rate Display
Quad Image Cine Display
Report writer (option)
Cine Gauge and Cine Image Number Display
On-board reporting package automates report writing
Cine Review Loop
Formats various exam results into a report suitable for
Cine Review Speed
printing or reviewing on a standard PC
Exam result reports can include patient info, exam info,
Image storage
measurements, calculations, images, comments and
On-board database of patient information from past exams physician diagnosis
Storage Formats:
Standard templates provided
• DICOM – compressed/uncompressed, single/multiframe,
with/without Raw Data Customizable templates
• Export JPEG, JPEG2000, WMV, MPEG 4 and AVI formats
Scanning parameters
Storage Devices:
• USB Memory Stick: 64 MB to 4 GB (for exporting individual Displayed Imaging Depth: 0 – 33 cm
images/clips) Minimum Depth of Field: 0 – 2 cm (Zoom) (probe dependent)
• CD-R storage: 700 MB Maximum Depth of Field: 0 – 33 cm (probe dependent)
• DVD storage: -R (4.7 GB)
Continuous Dynamic Receive Focus/Continuous Dynamic
• Hard Drive Image Storage: ~358 GB
Receive Aperture
Compare old images with current exam
Adjustable Dynamic Range
Reload of archived data sets
Adjustable Field of View (FOV)
Connectivity & DICOM Image Reverse: Right/Left
Ethernet network connection Image Rotation of 0°, 180°
DICOM 3.0 (option)
General system parameters (cont.)
Digital B-Mode Digital power Doppler imaging
Adjustable: Adjustable:
• Acoustic Power • Scanning Size (FOV or • Acoustic Power • Spatial Filter
• Gain Angle – depending on the • Color Maps including • Steering Angle
• Dynamic Range probe, see probe velocity-variance maps • Frame Average
• Frame Averaging specifications) • Gain • Threshold
• Gray Scale Map • Reject • Velocity Scale Range • Accumulation Mode
• Frequency • Suppression • Wall Filter • Sample Volume Control
• Line Density • SRI-HD • Packet Size • Flash Suppression
• B Colorization • Edge Enhance • Line Density

Digital M-Mode Continuous wave Doppler imaging


Adjustable: Adjustable:
• Acoustic Power • Sweep Speed • Acoustic Power • Angle Correction
• Gain • M Colorization • Gain • Spectrum Inversion
• Dynamic Range • M Display Format • Dynamic Range • Trace Method
• Gray Scale Map • Rejection • Gray Scale Map • Baseline Shift
• Frequency • Transmit Frequency • Doppler Auto Trace
• Wall Filter • Compression
Anatomical M-Mode • CW Colorization • Trace Direction
• Velocity Scale Range • Trace Sensitivity
M-Mode cursor adjustable at any plane
• Sweep Speed
Can be activated from a Cine loop from a live or stored image
M and A capability Coded harmonic imaging
Available with Color Flow Mode Available on all 2D probes
Curved Anatomical M-Mode
Automatic optimization
Digital spectral Doppler mode
Optimize B-Mode image to improve contrast resolution
Adjustable: Selectable amount of contrast resolution improvement (low,
• Acoustic Power • Angle Correction medium, high)
• Gain • Steered Linear
Auto TGC
• Dynamic Range • Spectrum Inversion
• Gray Scale Map • Trace Method Auto-Spectral Optimize adjusts
• Transmit Frequency • Baseline Shift • Baseline • PRF (on live image)
• Wall Filter • Doppler Auto Trace • Invert • Angle correction
• PW Colorization • Time Resolution
• Velocity Scale Range • Compression B-Flow/B-Flow color (option)
• Sweep Speed • Trace Direction Available on L6-12-RS probes
• Sample Volume Length • Trace Sensitivity Background: On/Off
Sensitivity/PRI
Digital color flow mode
Line Density
Adjustable:
Edge Enhance
• Acoustic Power • Steering Angle
• Color Maps, including • Baseline Shift Frame Average
velocity-variance maps • Frame Average Gray Scale Map
• Gain • Threshold Tint Map
• Velocity Scale Range • Accumulation Mode
Dynamic Range
• Wall Filter • Sample Volume Control
• Packet Size • Flash Suppression Rejection
• Line Density • Quantification (option) Gain
• Spatial Filter Dual Beam
B-Flow color
Accumulation
Time Intensity Curve (TIC) Analysis
Auto MI control
General system parameters (cont.)
LOGIQ View (option)
Extended Field of View Imaging 8 default templates
Available on 4C-RS, E8C-RS, 3Sc-RS, RAB2-6-RS, 8C-RS Baseline level/Previous level selectable
and L6-12-RS probes Raw data continuous capture
For use in B-Mode Over 100 sec available
CrossXBeam is available on linear probes Wall motion scoring (bulls-eye and segmental)
Auto detection of scan direction Smart stress: Automatically set up various scanning
Pre or post-process zoom parameters (for instance, geometry, frequency, gain,
Rotation etc.) according to same projection on previous level
Auto fit on monitor
Virtual convex
Measurements in B-Mode
Provides a convex field of view
3D Compatible with CrossXBeam
Allows unlimited rotation and planar translations Available on all linear and sector probes
3D reconstruction from Cine sweep
SRI-HD
Advanced 3D (option) Speckle Reduction Imaging
Acquisition of Color data Provides multiple levels of speckle reduction
Automatic rendering Compatible with Side by Side DualView Display
3D Landscape technology Compatible with all linear, convex and sector probes
3D Movie Compatible with B-Mode, Color and 3D imaging

Elastography (option) CrossXBeam

Available on L6-12-RS probes Provides 3, 5, 7 or 9 angles of spatial compounding


Semi-Quantification1 Live Side by Side DualView Display
Compatible with:
Scan Assistant (option) • Color Mode • Coded Harmonic Imaging
• PW • Virtual Convex
Factory Programs
• SRI-HD
User defined programs
Available on 4C-RS, E8C-RS, 8C-RS, RAB2-6-RS and L6-12-RS
Steps include image annotations, mode transitions, basic probes
Imaging controls and measurement initiation
Controls available while "live"
TVI (option) Write Zoom
Myocardial Doppler Imaging with color overlay on tissue image B/M/CrossXBeam-Mode
Available on the sector probes Gain
Tissue color overlay can be removed to show just the 2D image, TGC
still retaining the tissue velocity information Dynamic Range
Curved Anatomical M-Mode: free (curved) drawing of M-Mode Acoustic Output
generated from the cursor independent from the axial plane
Transmission Focus Position
Q-Analysis: Multiple Time Motion trace display from selected
points in the myocardium Transmission Focus Number
Line Density Control
Stress echo (option) Sweep Speed for M-Mode
Advanced and flexible Stress Echo examination capabilities Number of Angles for CrossXBeam
Provides exercise and pharmacological protocol templates PW-Mode
Template editor for user configuration of existing templates Gain
or creation of new templates Dynamic Range
References can display during acquisition for stress level Acoustic Output
comparison (dual screen) Transmission Frequency
General system parameters (cont.)
Controls available while "live" (cont.)
PRF Angle Correct
Wall Filter Quick Angle Correct
Spectral Averaging Auto Angle Correct
Sample Volume Gate Color Flow
• Length Overall Gain (loops and stills)
• Depth
Color Map
Velocity Scale
Transparency Map
Color Flow Mode
Frame Averaging (loops only)
CFM Gain
Flash Suppression
CFM Velocity Range
CFM Display Threshold
Acoustic Output
Spectral Invert for Color/Doppler
Wall Echo Filter
Anatomical M-Mode on Cine loop
Packet Size
Frame Rate Control Measurements/calculations
CFM Spatial Filter General B-Mode
CFM Frame Averaging Depth and Distance
CFM Line Resolution Circumference (Ellipse/Trace)
Frequency/Velocity Base Line Shift Area (Ellipse/Trace)
Volume (Ellipsoid)
Controls available on “freeze” or recall
% Stenosis (Area or Diameter)
Automatic Optimization
Angle between two lines
SRI-HD
CrossXBeam – Display non-compounded and compounded General M-Mode
Image simultaneously in split screen M-Depth
3D reconstruction from a stored Cine loop Distance
B/M/CrossXBeam Mode Time
Gray Map Optimization Slope
TGC Heart Rate
Colorized B and M
Frame Average (loops only) General Doppler measurements/calculations
Dynamic Range: Anatomical M-Mode Velocity
Max Read Zoom to 8x: Base Line Shift Time
Sweep Speed A/B Ratio (Velocities/Frequency Ratio)
PW Mode PS (Peak Systole)
Gray Map ED (End Diastole)
Post Gain PS/ED (PS/ED Ratio)
Baseline shift ED/PS (ED/PS Ratio)
Sweep Speed AT (Acceleration Time)
Invert Spectral wave form ACCEL (Acceleration)
Compression TAMAX (Time Averaged Maximum Velocity)
Rejection Volume Flow (TAMEAN and Vessel Area)
Colorized Spectrum Heart Rate
Display Format PI (Pulsatility Index)
Doppler Audio RI (Resistivity Index)
Measurements/calculations (cont.)
Real-time Doppler auto measurements/calculations GYN measurements/calculations
PS (Peak Systole) Right Ovary Length, Width, Height
ED (End Diastole) Left Ovary Length, Width, Height
MD (Minimum Diastole) Uterus Length, Width, Height
PI (Pulsatility Index) Cervix Length, Trace
RI (Resistivity Index) Ovarian Volume
AT (Acceleration Time) ENDO (Endometrial thickness)
ACC (Acceleration) Ovarian RI
PS/ED (PS/ED Ratio) Uterine RI
ED/PS (ED/PS Ratio) Follicular measurements
HR (Heart Rate) Summary Reports
TAMAX (Time Averaged Maximum Velocity)
PVAL (Peak Velocity Value) Vascular measurements/calculations
Volume Flow (TAMEAN and Vessel Area) SYS DCCA (Systolic Distal Common Carotid Artery)
DIAS DCCA (Diastolic Distal Common Carotid Artery)
OB measurements/calculations SYS MCCA (Systolic Mid Common Carotid Artery)
Gestational Age by • BD (Binocular Distance) DIAS MCCA (Diastolic Mid Common Carotid Artery)
• GS (Gestational Sac) • FT (Foot Length) SYS PCCA (Systolic Proximal Common Carotid Artery)
• CRL (Crown Rump Length) • OFD (Occipital Frontal
DIAS PCCA (Diastolic Proximal Common Carotid Artery)
• FL (Femur Length) Diameter)
• BPD (Biparietal Diameter) • TAD (Transverse Abdominal SYS DICA (Systolic Distal Internal Carotid Artery)
• AC (Abdominal Diameter) DIAS DICA (Systolic Distal Internal Carotid Artery)
Circumference) • TCD (Transverse SYS MICA (Systolic Mid Internal Carotid Artery)
• HC (Head Circumference) Cerebellum Diameter)
DIAS MICA (Diastolic Mid Internal
• APTD x TTD (Anterior/Posterior • THD (Thorax Transverse
Carotid Artery)
Trunk Diameter by Transverse Diameter)
Trunk Diameter) • TIB (Tibia Length) SYS PICA (Systolic Proximal Internal Carotid Artery)
• FTA (Fetal Trunk • ULNA (Ulna Length) DIAS PICA (Diastolic Proximal Internal Carotid Artery)
Cross-sectional Area • HL (Humerus Length) SYS DECA (Systolic Distal External Carotid Artery)
Estimated Fetal Weight (EFW) by: DIAS DECA (Diastolic Distal External Carotid Artery)
• AC, BPD • AC, FL, HC SYS PECA (Systolic Proximal External Carotid Artery)
• AC, BPD, FL • AC, HC
• AC, BPD, FL, HC • BPD, APTD, TTD, FL DIAS PECA (Diastolic Proximal External Carotid Artery)
• AC, FL • BPD, APTD, TTD, SL VERT (Systolic Vertebral Velocity)
Calculations and Ratios: SUBCLAV (Systolic Subclavian Velocity)
• FL/BPD • CI (Cephalic Index) Automatic IMT
• FL/AC • AFI (Amniotic Fluid Index) Summary Reports
• FL/HC • CTAR (Cardio-Thoracic
• HC/AC Area Ratio)
Urological calculations
Measurements/Calculations by: ASUM, ASUM 2001, Berkowitz,
Bladder Volume
Bertagnoli, Brenner, Campbell, CFEF, Chitty, Eik-Nes, Ericksen,
Goldstein, Hadlock, Hansmann, Hellman, Hill, Hohler, Jeanty, Prostate Volume
JSUM, Kurtz, Mayden, Mercer, Merz, Moore, Nelson, Osaka Lt/Rt Renal Volume
University, Paris, Rempen, Yarkoni, Robinson, Shepard, Generic Volume
Shepard/Warsoff, Tokyo University, Tokyo/Shinozuka, Fetal
Post-Void Bladder Volume
Graphical Trending, Growth Percentiles, Multi-Gestational
Calculations (4), Fetal Qualitative Description (Anatomical
survey), Fetal Environmental Description (Biophysical profile),
Programmable OB Tables, Over 20 selectable OB Calculations,
Expanded Worksheets.
LOGIQ P7 Probes
4C-RS Inputs and outputs
(Micro Convex Biopsy Probe)
HDMI Out
Applications Abdomen, OB/GYN, Urology
Ethernet Network (RJ45)
Biopsy Guide Multi-Angle, disposable with
S-Video Out
a reusable bracket
(E8385NA) Composite Video Out
USB (2x in front, 3x in rear, 2x monitor)
8C-RS AC Power Input
(Micro Convex Probe)
Applications Neonatal, Pediatrics Safety conformance
Biopsy Guide available No The LOGIQ P7 is:
Classified to UL 60601-1 by a Nationally Recognized Test Lab
E8C-RS
(Endo Micro Convex Probe) Certified to CAN/CSA-C22.2 No. 601.1-M90 by an SCC
accredited Test Lab
Applications OB/GYN, Urology,
CE Marked to Council Directive 93/42/EEC on Medical Devices
Transrectal, Transvaginal
Conforms to the following standards for safety:
Biopsy Guide Single Angle, disposable with
• IEC 60601-1 2nd Edition. Medical electrical equipment – Part 1:
a disposable bracket
General requirements for safety
(E8385MJ, E8333JB), Single-
• IEC 60601-1 3rd Edition. General requirements for basic
Angle, Reusable bracket
safety and essential performance.
(H40412LN)
• IEC 60601-1-1 Medical electrical equipment – Part 1-1:
General requirements for safety – Collateral Standard:
L6-12-RS
Safety requirements for medical electrical systems
(Linear Probe)
• IEC 60601-1-2 Medial electrical equipment – Part 1-2:
Applications Vascular, Small Parts, General requirements for safety – Collateral Standard:
Neonatal, Pediatrics, Electromagnetic compatibility – requirements and tests
Musculoskeletal, Abdomen, • IEC 60601-1-4 Medical electrical equipment Part 1- 4
Biopsy Guide Multi-Angle, disposable with General requirements for safety – Collateral Standard:
a reusable bracket programmable electrical medical systems
(H40432LC) • IEC 60601-1-6 Medical electrical equipment Part 1-6 General
requirements for basic safety and essential performance –
3Sc-RS Collateral Standard: Usability
(Phased Array Sector Probe) • IEC 60601-2-37 Medical electrical equipment – Part 2-37:
Particular requirements for the safety of ultrasonic medical
Applications Cardiac, Abdomen,
diagnostic and monitoring equipment
Transcranial
• ISO 10993-1 Biological evaluation of medical devices – Part 1
Biopsy Guide Multi-Angle, disposable with Evaluation and testing
a reusable bracket • NEMA UD2 Acoustic output measurement standard for
(H46222LC) diagnostic ultrasound equipment
• NEMA UD3 Standard for real time display of thermal and
6S-RS mechanical acoustic output indices on diagnostic ultrasound
(Phased Array Sector Probe) equipment (MI, TIS, TIB, TIC)
Applications Cardiac Neonatal, Pediatrics EMC Emissions Group 1 Class B device requirements as per
Biopsy Guide No Sub clause 4.2 of CISPR 11
EMC Emissions Group 1 Class A device requirements as per
RAB2-6-RS Sub clause 4.2 of CISPR 11 (Only with 6S-RS)
(Convex Volume Probe)
Applications Abdomen, OB/GYN, Urology
Biopsy Guide Multi-Angle, disposable with
reusable bracket (H48681ML)

P8D
(CW Split Crystal Probe)
Applications Cardiac, Vascular
1 Elastography with semi-Quantification (Elastography Quantification)
described in this material has not been cleared by the U.S. FDA and is
not available for promotion or sale in the United States.
The LOGIQ P7 is a highly mobile and easy to use, performance multipurpose
color Doppler imaging system, designed for Abdominal, Small Parts,
Musculoskeletal, Breast, Vascular, Cardiology, Transcranial, Urology, Pediatric,
Neonatal, Obstetrics and Gynecology applications.

©2015 General Electric Company – All rights reserved.


General Electric Company reserves the right to make changes in specifications and
features shown herein, or discontinue the product described at any time without notice
or obligation. Contact your GE Representative for the most current information.
GE and GE Monogram are trademarks of General Electric Company or one of
its subsidiaries
LOGIQ, B-Flow, InSite and CrossXBeam are trademarks of General Electric Company.
DICOM is the registered trademark of the National Electrical Manufacturers Association for
its standards publications relating to digital communications of medical information.
GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric
company, doing business as GE Healthcare.
GE Healthcare
9900 Innovation Drive
Wauwatosa, WI 53226
U.S.A.
www.gehealthcare.com

Global
January 2015
DOC1523554