SITE DATA DESIGN DATA INDEX OF DRAWINGS GENERAL NOTES 200 AMP. W.P. DISCONNECT
6FT ABOVE GRADE
SITE CALCULATIONS
CALLING SUNSHINE UTILITY LOCATE SERVICE PRIOR TO ANY CONSTRUCTION WITHIN ANY
PUBLIC RIGHT-OF-WAY OR OTHER AREAS WHERE UNDERGROUND UTILITIES MAY BE
PRESENT (I.E. IN AND AROUND UTILITY EASEMENTS, ETC.)
ELECTRIC SERVICE DETAIL
8. THE GENERAL CONTRACTOR SHALL PROVIDE AN ON-SITE DUMPSTER IN A LOCATION
COORDINATED WITH THE OWNER FOR THE DISPOSAL OF REMOVED MATERIAL AND SCALE:NTS
PROPOSED OPEN SPACE RATIO: 4,979 sf = 71% CONSTRUCTION DEBRIS. THE DUMPSTER SHALL BE EMPTIED AT APPROPRIATE INTERVALS
16"X16" CONCRETE COLUMN
TO PREVENT OVERFLOW AND UNSIGHTLY CONDITIONS. RICHARD J. MILELLI
9. THE CONTRACTOR SHALL PERFORM ALL WORK IN STRICT CONFORMANCE WITH THE ELECTRICAL NOTES PE #58315
PLANS, 2020 FLORIDA BUILDING CODE, LOCAL CODES AND ORDINANCES, MANUFACTURER
RECOMMENDATIONS AND ACCEPTABLE TRADE PRACTICES. ANY CONFLICT BETWEEN 1. THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, LABOR, EQUIPMENT AND SUPERVISION NECESSARY
THESE REQUIREMENTS AND THE MOST STRINGENT REQUIREMENTS SHALL GOVERN THE TO PROVIDE THE WORK COMPLETE AND READY TO USE.
WORK. 2. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL
10. SHOP DRAWINGS OF ALL PREFABRICATED STRUCTURAL FLOOR AND ROOF SYSTEMS ELECTRICAL CODE (NEC) AND ALL OTHER APPLICABLE CODES AND STANDARDS.
DFE +9.0' NGVD
AND MECHANICAL SYSTEMS SHALL BEAR THE SEAL OF A FLORIDA PROFESSIONAL 3. NO PIPE, CONDUIT OR JUNCTION BOX SHALL BE INSTALLED IN STRUCTURAL SLABS, COLUMNS OR
ENGINEER AS REQUIRED BY THE 2020 FLORIDA BUILDING CODE AND SHALL BE SUBMITTED BEAMS UNLESS SPECIFICALLY SHOWN ON STRUCTURAL DRAWINGS. BFE +8.0' NGVD
TO THE ENGINEER OF RECORD BY THE CONTRACTOR FOR APPROVAL PRIOR TO 4. THE CONTRACTOR SHALL COORDINATE WITH THE LOCAL UTILITY COMPANY FOR NEW SERVICE AND
FABRICATION AND INSTALLATION. ANY SPECIAL REQUIREMENTS.
11. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. ANY INFORMATION THAT THE 5. ALL CUTTING AND NOTCHING REQUIRED FOR THE INSTALLATION OF ELECTRICAL WORK SHALL BE
CONTRACTOR CANNOT OBTAIN FROM DIMENSIONS, DETAIL OR SCHEDULE SHALL BE ACCOMPLISHED IN AN APPROVED MANNER. APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR
OBTAINED FROM THE ENGINEER OF RECORD. TO CUTTING OR DRILLING STRUCTURAL MEMBERS UNLESS SPECIFICALLY ADDRESSED HEREIN.
12. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO PREVENT ANY 6. ALL WIRE SIZE SHALL BE #12 THHN/THWN UNLESS OTHERWISE NOTED ON DRAWINGS. CONDUCTORS #6 SLAB HEIGHT 4.2'
CONFLICTS. AND LARGER SHALL BE THW. C.O.R. GRADE 4.13'
13. THE CONTRACTOR SHALL FURNISH ALL SUBCONTRACTORS WITH A COMPLETE SET OF 7. ALL CONDUCTORS SHALL BE COPPER.
PLANS. ALL CHANGES SHALL BE NOTED ON THE DRAWINGS AND (2) COMPLETE AS-BUILT 8. ALL MATERIAL SHALL BE UL APPROVED.
SETS SHALL BE DELIVERED TO THE OWNER AFTER COMPLETION OF WORK. 9. A TYPEWRITTEN PANEL TALLY SHALL BE AFFIXED TO THE PANEL DOOR AFTER COMPLETION OF WORK
PRE CONSTRUCTION EXISTING GRADE 3.5'
14. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE THAT REFLECTS ALL CHANGES AND ADDITIONS. NOTE: ALL ELEVATIONS TO BE NGVD
ENERGY REQUIREMENTS OF THE FLORIDA MODEL ENERGY CODE. THE CONTRACTOR 10. ALL BRANCH CIRCUITS SHALL BE EQUIPPED WITH A GREEN EQUIPMENT GROUNDING CONDUCTOR
SHALL FAMILIARIZE HIMSELF WITH THE GOVERNING CODE IN ITS ENTIRETY AND BUILD IN SIZED IN ACCORDANCE WITH NEC 250.95.
BUILDING SECTION
General Notes:
ACCORDANCE WITH ALL PROVISIONS OF THIS CODE. 11. FUSES SHALL BE DUAL ELEMENT, TIME DELAY UNLESS OTHERWISE NOTED.
15. PORTABLE RESTROOM FACILITIES TO BE PROVIDED AT THE SITE BY THE CONTRACTOR. 12. ALL LUMINAIRES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH CEILING MANUFACTURER
RECOMMENDATIONS IF APPLICABLE AND LOCAL REQUIREMENTS.
13. ALL GARAGE AND EXTERIOR RECEPTACLE OUTLETS SHALL BE GFI PROTECTED. ALL EXTERIOR
RECEPTACLE OUTLETS SHALL BE WATER-PROOF PROTECTED.
SCALE:NTS
SITE NOTES
124.47'
MEAS
112.55' MEAS
112.50' PLAT
FOUNDATION PLAN
3.5
℄
Revisions:
3.5
4.2
3.5 3.9' 3.7' 3.6'
Title:
SITE
PLAN
112.55' MEAS
112.50' PLAT Sheet Number:
12"
MOISTURE AFTER THE FINISH HAS SET, OR THE CONCRETE COVERED AND SPRAYED.
AUTHORIZATION #34715
16"
10. ALL REINFORCING SHALL BE HIGH STRENGTH DEFORMED BARS CONFORMING TO ASTM A-615, GRADE 60. TYPE X 5/8" DRYWALL ph:305-481-0400
11. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 AND SHALL BE LAPPED ONE FULL MESH AND AT SIDE AND END TAPED AND PRIMED
SPLICES AND WIRED TOGETHER.
12. REINFORCEMENT COVERAGE SHALL BE 2" MINIMUM WHEN FORMS ARE USED AND 3" MINIMUM WHEN POURED AGAINST
OR GOLD BOND 5/8" XP FIRE
SHIELD DRYWALL
(3) #5 TOP BARS, HOOKED
MIDDLE COLUMN ANCHOR DETAIL Seal:
THE EARTH, UNLESS OTHERWISE NOTED.
90°, 12" LONG
13. LAP SPLICES SHALL BE A MINIMUM OF 48 BAR DIAMETERS. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
14. PROVIDE ALL ACCESSORIES NECESSARY TO SECURE REINFORCING IN PROPER POSITION AS INDICATED ON THE SCALE: N.T.S.
(3) #5 BOTTOM BARS,
DRAWINGS AND IN ACCORDANCE WITH ACI 318. ALL ACCESSORIES TO BE GALVANIZED. 16"X16" CONCRETE HOOKED 90°, 12" LONG
15. ANCHOR BOLTS, NUTS AND WASHERS SHALL BE MINIMUM 5 8" GALVANIZED STEEL AND EMBEDDED MINIMUM 7" INTO COLUMN
CONCRETE AND SPACED MAXIMUM 4' CC
#3 STIRRUPS, 3 @ 2"
16. MANUFACTURED STRAPS AND ANCHORS SHALL BE GALVANIZED AND SHALL BE FASTENED PER THE MANUFACTURER
REST @ 6" BEAM BY MODULAR
RECOMMENDATIONS. IN NO EVENT SHALL A STRUCTURAL MEMBER SUCH AS PIER, SILL, JOIST, PLATE, RAFTER OR TRUSS BE
HOME MANUFACTURER
WITHOUT ANCHORAGE DEVICES FOR HURRICANE PROTECTION, UNLESS SPECIFICALLY NOTED AND ADDRESSED BY OTHER FINISHED FLOOR
MEANS.
STAIR PORCH DETAIL
WOOD AND FRAMING NOTES RICHARD J. MILELLI
1. EXCEPT WHERE NOTED OTHERWISE, ALL FRAMING LUMBER SHALL BE SOUTHERN PINE, MC 19%, NO. 2 DENSE, SCALE: N.T.S. HD5B SIMPSON STRONG TIE PE #58315
AS GRADED BY THE SOUTHERN PINE INSPECTION BUREAU. INSTALL (2) BOLTS PER COLUMN
2. ALL TIMBER CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION AFTC. IN CASE OF CONFLICT WITH JOIST 30 LB FELT BETWEEN
3. ALL WOOD SHALL BE PRESSURE TREATED WITH CHEMICALS TO PROTECT FROM INSECTS AND DECAY. ALLOW HANDRAIL AND GUARDRAIL TO BE CONTRACTOR IS TO REMOVE 1 BOLT WOOD BEAM AND CONC.
TO DRY AFTER TREATMENT. PROVIDE CONNECTORS AND FASTENERS COMPATIBLE WITH PRESSURE TREATED CONSTRUCTED TO WITHSTAND A SO THAT (1) SIMPSON HD5B IS TO BE
WOOD FRAMING. PROVIDE SEPARATION BARRIER SUCH AS BUILDING PAPER FOR NON-COMPATIBLE COMPONENTS CONCENTRATED LOAD OF 200LBS. INSTALLED PER COLUMN,
SUCH AS ALUMINUM WINDOW FRAMES. APPLIED AT ANY POINT IN ANY CONTRACTOR IS TO INSTALL (2) IN
4. ALL WOOD CONNECTIONS SHALL HAVE SIMPSON STRONG-TIE CO. OR EQUAL CONNECTORS. ALL CONNECTORS DIRECTION. EACH CORNER COLUMN 16"X16" CONC.
6' COLUMN
SHALL BE INSTALLED WITH MANUFACTURER RECOMMENDED FASTENERS BEFORE LOADING. 2X4 P.T. FASTENED TO UNDERSIDE OF BEAM MODULAR HOME
5. PROVIDE BLOCKING BETWEEN ALL JOISTS 2 X 6 OR GREATER AT INTERVALS NOT TO EXCEED 8 FEET AND AT 1/4" STEEL 2X10 JOIST W/ SIMPSON
USING 1/4" S.S. LAG SCREWS EVERY 16" O.C.
3"
ALL SUPPORTS.
6. WHERE WOOD JOISTS/BEAMS ETC. FRAME INTO OTHER MEMBERS INSTALL SIMPSON "LUS" SERIES GALVANIZED
JOIST HANGERS.
(3) 5/8" THROUGH BOLTS FLASHING
META 12 ANCHORS @
EACH JOIST SIDE COLUMN ANCHOR DETAIL
5/4X6 DECKING
6"
BETWEEN DECK
AND HOUSE BEAM
SCALE: N.T.S.
5"
(2)2X10 BEAM WITH
SIMPSON HD3B W/ 5/8"
2X6 P.T.
PLUMBING NOTES PINE TREADS
ANCHOR AT EACH
CANTILEVER
PROVIDE GALVANIZED
20"
1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT AND SUPERVISION
ANCHOR; MIN. 8" EMBEDMENT 1X6 PT REJECT PASSAGE (3) #6 TOP BARS, HOOKED
NECESSARY TO PROVIDE THE WORK COMPLETE AND READY FOR USE. THE NEW WORK SHALL 3" 4" THICK CONCRETE SLAB
12"
16"
INCLUDE COMPLETE HOT AND COLD WATER SYSTEMS AND VENT, WASTE AND DRAIN SYSTEMS IN OF 4" SPHERE 90°, 24" LONG
W/ 6"X6" #10/#10 W.W.M.
General Notes:
ACCORDANCE WITH ALL APPLICABLE CODES. AND VAPOR BARRIER
2. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2020 FLORIDA RESIDENTIAL 4" 2X12 P.T. PINE
30" OR LESS
BUILDING CODE STAIR CARRIAGE (3) #6 BOTTOM BARS,
3. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. HOOKED 90°, 24" LONG
4. PROVIDE FULLY ACCESSIBLE CLEANOUTS ON SANITARY PIPING AT THE BASE OF EACH SOIL AND 2X2 P.T. PICKETS FASTENED TO 16"X16" CONC.
ANCHOR SOURCE: KEY WEST WELDING 2X4 AND STAIR STRINGERS USING
WASTE PIPE AND AT EVERY CHANGE OF DIRECTION. COLUMN #3 STIRRUPS, 3 @ 2"
12"
(2) 3" S.S. DECK SCREWS AT TOP AND
5. PROVIDE MINIMUM PITCH OF 1 4" PER FOOT FOR ALL HORIZONTAL BRANCHES AND SEWER TRADES.
6. ALL WATER PIPING SHALL BE TYPE M COPPER WITH WROUGHT COPPER SOLDERED JOINT FITTINGS.
7. PROVIDE DIELECTRIC FITTINGS FOR JOINING DISSIMILAR METALS.
BRACKET DETAIL BOTTOM
REST @ 6"
(2) #5 CONTINUOUS
8. SANITARY DRAIN PIPING WITHIN THE BUILDING AND BELOW THE GROUND SHALL BE SCHEDULE 40
PVC. SCALE:NTS STAIR PICKET DETAIL REAR PORCH DETAIL 12"
9. ALL PIPING SHALL BE SUPPORTED RIGIDLY.
10. HOSE BIBS SHALL BE PROTECTED BY APPROVED BACK-SIPHONAGE BACKFLOW PREVENTERS. SCALE: N.T.S. SCALE: N.T.S.
11. TEST ALL WATER PIPING AT WORKING PRESSURE OF PIPE A MINIMUM OF 15 MINUTES.
12. TEST ALL SOIL, WASTE AND VENT PIPING WITH A 5' HEAD OF WATER. WATER LEVEL TO REMAIN
THRU BOLT
UNIT THICKENED EDGE DETAIL
UNCHANGED FOR 15 MINUTES MINIMUM. ACCORDING
13. THE CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF DRAWINGS TO INDICATE ALL TO MANUF. SCALE:NOT TO SCALE
FOUNDATION PLAN
CHANGES MADE TO THE PLUMBING DESIGN. THE AS-BUILT DRAWINGS SHALL BE DELIVERED TO THE CONCRETE LANDING
INSTRUCTIONS 23 RISERS @ 7 1/2" SIMPSON LRU210Z
OWNER AFTER COMPLETION OF WORK.
23 THREADS @ 11" STRINGER CONNECTION
14. COORDINATE INSPECTION WITH MONROE COUNTY AND KEY WEST RESORT UTILITIES. SIMPSON HL53 STRINGER CONTRACTOR TO TYP.
TO CONC. CONNECTION FIELD VERIFY
MOUNT 1FT
ABOVE BASE
PT (2)2X10 BEAM
PT (2)2X10 BEAM
AC CONDENSER LOCATION
PT (2)2X10 BEAM
ANCHOR BOLTS
PER HATCH DENOTES CONC.
MANUFACTURER'S CANTILEVER
SPECS SIMPSON LUS28Z
SIMPSON HUC2102Z EACH END SIMPSON HUC2102Z ATTACH 2X10 LEDGER
PT (2)2X10 BEAM
WITH 1/2" LAG SCREWS 16" O.C. W/ (2) AT ENDS
A/C BRACKET DETAIL STAGGERED
Revisions:
PT (2)2X10 BEAM
PLACING 4,000 PSI SIMPSON META 12 JOIST ANCHOR
CONCRETE FROM MODULAR HOME DIFFER
PT (2)2X10 BEAM
16" X 16" CONC.
THROUGH BOLTS COLUMN ALL STEEL CANTILEVER
CONCRETE COLUMN PT 2X8 JOISTS 16" O.C. PT 2X12 STRINGER 12" O.C. PT 2X12 STRINGER 12" O.C.
4" THICK CONC. PT 2X10
Title:
2X12 P.T. PINE SLAB WITH 6"X6" #3 TIES @ 10" O.C. JOISTS 16"
STAIR STRINGER #10/#10 W.W.M. CAGE SHOULD BE A MIN. O.C. FOUNDATION
SIMPSON ABU66 OF 10" SQUARE
PLAN
1X6 PT PT (2)2X10 BEAM AND DETAILS
16"
COLUMN DETAIL
16" TYP. CONTRACTOR TO
FIELD VERIFY
CONCRETE LANDING
S-2.0
TYPICAL STAIR DETAIL FOUNDATION PLAN Date: 7.28.2022
SCALE:1"=1'-0"
SCALE:NOT TO SCALE SCALE:1/4"=1'-0"