-: Specifications
SPECIFICATIONS
Hydraulic Oil Temperature 45—55° C
110—130° F
Engine Speed Fast Idle
Power Mode Switch Position S (standard)
Auto Idle Switch Position Off
Travel Speed Position Slow (turtle)
One Revolution of Raised Track Cycle Time 11.1—11.3 sec.
The purpose of this test is to check and adjust hydraulic pump 1 and 2 minimum flow rates.
1. Check and adjust track sag. See Check and Adjust Track Tension . (Operator's Manual.)
2. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure . (Group 9025-25.)
3. Release hydraulic oil tank pressure. See Hydraulic Oil Tank Pressure Release Procedure . (Group 9025-25.)
4.
TX1073187-UN: Hydraulic Oil Pump Regulators
LEGEND:
Disconnect hydraulic oil pump 1 and 2 regulator pilot lines (4 and 7). Cap and plug all openings.
file:///C:/ProgramData/Service%20ADVISOR/Temp/TM11583_09001faa811419cd.ht... 19/04/2020
Page 2 of 2
6. Turn upperstructure perpendicular to the tracks with the boom on the side with the track that will be used for the test.
Left track checks pump 1 and right track checks pump 2.
7.
CAUTION:
Prevent possible serious injury from machine sliding backwards. Keep angle between boom
and arm between 90—110°.
With the angle between the boom and arm between 90—110° , raise track off ground.
8. Actuate the track being tested to full speed. Record cycle time for one revolution.
9. NOTE:
Adjustment of minimum flow is required to have approximately equal track cycle time for both side
of machine.
Adjust minimum flow adjustment screw (2) on hydraulic oil pump 1 and 2 regulators (3 and 6) as necessary, to have
approximately the same track cycle times on both sides of machine. Turning adjustment screw in increases flow, out
decreases flow.
TP97644,0000141-19-20100311