Page 1 of 2

TM11583 - XCG210LC-8B Excavator Operation and Test


Pump Regulator Test and Adjustment—Minimum Flow

Pump Regulator Test and Adjustment—Minimum Flow

-: Specifications

SPECIFICATIONS
Hydraulic Oil Temperature 45—55° C
110—130° F
Engine Speed Fast Idle
Power Mode Switch Position S (standard)
Auto Idle Switch Position Off
Travel Speed Position Slow (turtle)
One Revolution of Raised Track Cycle Time 11.1—11.3 sec.

The purpose of this test is to check and adjust hydraulic pump 1 and 2 minimum flow rates.

1. Check and adjust track sag. See Check and Adjust Track Tension . (Operator's Manual.)

2. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure . (Group 9025-25.)

Item Measurement Specification

Hydraulic Oil Temperature 45—55° C


110—130° F

3. Release hydraulic oil tank pressure. See Hydraulic Oil Tank Pressure Release Procedure . (Group 9025-25.)

4.
TX1073187-UN: Hydraulic Oil Pump Regulators

LEGEND:

1 - Hydraulic Oil Pump 2


2 - Minimum Flow Adjustment Screw
3 - Hydraulic Oil Pump 2 Regulator
4 - Hydraulic Oil Pump 2 Regulator Pilot Line
5 - Maximum Flow Adjustment Screw
6 - Hydraulic Oil Pump 1 Regulator
7 - Hydraulic Pump 1 Regulator Pilot Line

Disconnect hydraulic oil pump 1 and 2 regulator pilot lines (4 and 7). Cap and plug all openings.

5. Run machine at specifications.

Item Measurement Specification

file:///C:/ProgramData/Service%20ADVISOR/Temp/TM11583_09001faa811419cd.ht... 19/04/2020
Page 2 of 2

Engine Speed Fast Idle

Power Mode Switch Position S (standard)

Auto Idle Switch Position Off

Travel Speed Position Slow (turtle)

6. Turn upperstructure perpendicular to the tracks with the boom on the side with the track that will be used for the test.
Left track checks pump 1 and right track checks pump 2.

7.

CAUTION:

Prevent possible serious injury from machine sliding backwards. Keep angle between boom
and arm between 90—110°.

With the angle between the boom and arm between 90—110° , raise track off ground.

8. Actuate the track being tested to full speed. Record cycle time for one revolution.

9. NOTE:

Adjustment of minimum flow is required to have approximately equal track cycle time for both side
of machine.

Adjust minimum flow adjustment screw (2) on hydraulic oil pump 1 and 2 regulators (3 and 6) as necessary, to have
approximately the same track cycle times on both sides of machine. Turning adjustment screw in increases flow, out
decreases flow.

Item Measurement Specification

One Revolution of Raised Track Cycle Time 11.1—11.3 sec.

TP97644,0000141-19-20100311