Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Component description

Electrohydraulic shut-off device EHAB


The EHAB (electrohydraulic shut-off device) is a safety-critical component.
The EHAB shuts off the fuel supply to the injection pump in the event of certain faults occurring in the EDC
system. The EHAB is connected into the fuel supply system between the delivery pump and pump suction
chamber. The EHAB reverses the delivery direction of the delivery pump so that the pressure in the suction
chamber is reduced rapidly thus interrupting the filling procedure.
Power is always applied to the EHAB during operation. The power circuit is interrupted by the EDC control
unit in order to activate the EHAB (e.g. for emergency engine shut-down).
For this reason, the ignition must be turned on when bleeding the fuel system by means of the presup-
ply pump.

2 1

T ÜV

Fi FP

4 3
5 6

3 4

2 1

Plug connection

15
Component description

Fuel circuit diagram – D 28 R engine

Suction chamber –
injection pump

EHAB 6 5

1ÜV 3 FP 2 T 4 Fi

Overflow valve Double filter box


Pre-deliv-
ery pump
(manual
pump)

Delivery pump

Prefilter

Fuel tank

17