Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

PRODUCT LINE

QUICK REFERENCE
MAGNETROL®: A HERITAGE OF LEADING-EDGE PRODUCTS CREATED THROUGH ENGINEERING EXCELLENCE

Leadership Solutions Innovation International


Since we invented and marketed Because process environments are We cultivate innovation through A key factor in maintaining innovation
our first level control in 1932, the so diverse, MAGNETROL has created sustained R&D commitment. Products and market leadership has been our
Magnetrol® name has become numerous technology groups to are engineered not only to perform development of a global informa-
synonymous worldwide with quality address the broad range of control accurately and reliably, but to be easy tion and distribution network. It’s a
and innovation. Today MAGNETROL challenges. Each technology group to install, calibrate, and maintain as network of technology experts poised
products serve industries in over features products that are highly well. Turning these better ideas into to lend assistance to our customers
100 countries. Our market leadership configurable enabling our customers better products is realized in the anywhere in the world anytime. You
is sustained by a strong ongoing com- to have the most exacting solution for MAGNETROL ISO-certified manufac- can always count on MAGNETROL for
mitment to advance the state-of-the- their specific process requirements. turing environment using leading- products that are engineered to the
art in level and flow technologies. edge fabrication systems. highest standards of excellence in the
industry.

VISION STATEMENT

To be the customer’s first call


when performance matters.
GUIDED WAVE RADAR RADAR

Eclipse® Eclipse® Pulsar® Pulsar® Radar


Model 706 GWR Model 700 GWR Model R86 Radar Model R96 Radar Model R82 Radar
Transmitter Transmitter Transmitter Transmitter Transmitter
Description: An advanced Description: 24 VDC loop Description: An advanced Description: An advanced Description: An economi-
24 VDC loop powered powered transmitter with loop-powered 4–20 mA level loop-powered 4–20 mA level cal loop-powered 4–20 mA
transmitter with proactive proactive diagnostics and transmitter with proactive transmitter with proactive level transmitter in a compact
diagnostics and superior sig- superior signal strength. Not diagnostics provides accurate diagnostics provides accurate single compartment housing.
nal strength. Not affected by affected by foam, turbulence, measurement even in shifting measurement even in shifting
foam, turbulence, and varying and varying media conditions. dielectric and varying media. dielectric and varying media.
media conditions.

Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle:
Guided Wave Radar Time Guided Wave Radar Time Pulse Burst Radar Pulse Burst Radar Pulse Burst Radar
Domain Reflectometry (TDR) Domain Reflectometry (TDR)

Applications: Applications: Applications: Applications: Applications:


Ideal for difficult, low Liquids and slurries, Liquids and slurries, Liquids and slurries, hy- Liquids and slurries, hy-
dielectric, high temperature hydrocarbon to water- hydrocarbons to water-based drocarbons to water-based drocarbons to water-based
process applications, high based media. Process and media, high temperature/high media, process or storage media, process or storage
pressure steam, or simple storage vessels to +400 °F pressure process or storage vessels vessels
storage applications. (+200 °C). vessels

Features: Features: Features: Features: Features:


• No calibration necessary • No calibration necessary • 26 GHz frequency offers • 6 GHz frequency • 26 GHz frequency
• General Purpose, • General Purpose, smaller beam angle and • 24 VDC, loop-powered • 24 VDC, loop-powered
Intrinsically Safe, Explosion Intrinsically Safe and Non- improved resolution • 4–20 mA with HART® • 4–20 mA with HART®
Proof and Non-Incendive Incendive approvals • Full vacuum to 2320 psi • 130' (40 m) measurement • 40' (12 m)
approvals • Increased signal strength (160 bar); -100 to +750 °F range measurement range
• Increased signal strength • Superior Signal-to-Noise (-70 to +400 °C) • Full vacuum to 750 psi • Full vacuum to 200 psi
• Superior Signal-to-Noise Ratio • Quick connect/disconnect (52 bar); -40 to +400 °F (14 bar); -40 to +200 °F
Ratio • Proactive Diagnostics antenna coupling allows (-40 to +200 °C) (-40 to +95 °C)
• Proactive Diagnostics • Full vacuum to 6250 psi vessel to remain sealed • Quick connect/disconnect • Configure with 2-line ×
• Broad offering of Overfill- (430 bar); -320 to +400 °F • Wide range of HTHP anten- antenna coupling allows 16-character display,
capable probes (-196 to +200 °C) nas, with extensions vessel to remain sealed 4-push-button keypad
• Full vacuum to 6250 psi • SIL 2/3 Certified with • Coated Isolation antennas • Intuitive false target setup • Adjustable beam pattern
(430 bar); -320 to +850 °F SFF = 93% (FMEDA avail- for corrosive applications General purpose, Intrinsi- without removing the trans-
(-196 to +450 °C) able upon request) • Intuitive false target setup cally Safe, Explosion Proof, mitter from vessel
• SIL 2/3 Certified with • Unique Commissioning and Intrinsically Safe, Explosion • General Purpose and Intrin-
SFF = 93% (FMEDA avail- Optimization Wizards Proof and Non-Incendive sically Safe
able upon request) • Proactive Diagnostics approvals
• Proactive diagnostics
Options: Options: Options: Options: Options:
Graphic LCD allows the Graphic LCD allows the Graphic LCD; HART®, Graphic LCD allows the view- Cast aluminum or Lexan
viewing of waveforms; HART®, viewing of waveforms; HART® Foundation fieldbus™ and ing of waveforms; HART® and enclosure, 2" or 8" (50 or
Foundation fieldbus™, digital communications Profibus PA digital com- Foundation fieldbus™ digital 200 cm) antenna extension,
Profibus PA and Modbus munications; Wide variety of communications; horn or polypropylene or Tefzel®
digital communications; broad horn antenna configurations, dielectric rod antenna con- antenna material
probe offering with numerous all-plastic antenna, antenna figuration, all-plastic antenna,
process connections extensions antenna extensions
THERMAL DISPERSION ULTRASONIC

Thermatel® Thermatel® Echotel® Echotel® Echotel®


Models TD1/TD2 Model TA2 Mass Model 910 Models 961/962 Model 355
Flow/Level Switch Flow Transmitter Level Switch Level Switches Transmitter
Description: Reliable flow/ Description: An easy-to-use, Description: Integral mount, Description: Universally Description: Loop-powered,
level/interface switch detects economical, continuous gas low cost ultrasonic level applied liquid level switch with integral mount, ultrasonic
changes in heat transfer due to flow meter to manage energy switch with worldwide safety advanced self-test capabilities, transmitter for level, volume, or
changes in media or flow rate. costs or meet environmental approvals. time delay and pulsed signal open channel flow.
regulations. technology for superior perfor-
mance in difficult applications.

Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle:
Thermal dispersion Thermal mass/dispersion Ultrasonic Ultrasonic Non-Contact 60 kHz ultrasonic

Applications: Applications: Applications: Applications: Applications:


Flow switch for liquids and Combustion air, compressed Clean liquids, wastewater, Water-based liquids, hydrocar- Open channel flow, simpler
gases. Popular for pump pro- air, natural gas, flare gas, aera- hydrocarbons, foods and bons, chemicals, low/high level level measurement with less
tection to detect low flow rates. tion lines, digester/biogas/LFG, pharmaceuticals, solvents, seal detection, overfill protection, vapors, foam and agitation
Also used for level/interface low flow/low pressure pot level seal pot level
detection

Features: Features: Features: Features: Features:


• Continuous diagnostics with • Direct mass flow • Tip sensitive gap style • Suitable for use in Safety • Two-wire, loop-powered
fault detection measurement • Integral mount unit with dual Integrity Level (SIL) 2 loops • 4–20 mA with HART®
• Temperature compensation • Calibration verification in conduit hubs • Adjustable time delay for • PACTware PC program
• mA output signal on TD2 the field prevents sending • Field selectable high or low turbulent aerated liquids • 20' (6 m) measurement
permits flow monitoring and unit back to the factory level fail-safe • Tip-sensitive transducer range
diagnostics • Strong signal at low flows • 8-amp DPDT gold flash or • Advanced self-test • Temperature compensated
• Temperatures to +850 °F and low pressures 5-amp DPDT hermetically technology with malfunction echo rejection profile
(+450 °C), pressure to 6000 • High turndown ratio sealed relay alarm output • Dynamic baseline noise
psi (410 bar) • Rotatable head and display • Vertical or horizontal mount • Integral or remote mount compensation
• Adjustable set point and time for ease of viewing and • No calibration required electronics • Open channel flow equations
delay proper installation • Two-year warranty • Pulsed signal technology • Resettable and
• Available for single (961) or non-resettable flow totalizers
dual point (962) liquid level
detection.
• Plastic probes available

Options: Options: Options: Options: Options:


Relay type, input voltage, 2-line × 16-character display, Housings, process connections, Housing materials, input Cast aluminum or Lexan enclo-
integral or remote mounting, HART® and Foundation fieldbus™ input power, relay type, and power, output signal, integral or sure, polypropylene or Kynar®
window to view LEDs, probe digital communications, probe actuation length remote mounting and actuation Flex transducer
types and probe process con- length, process connection, length
nections Hot Tap, temperature output
and pulse output, remote
electronics
BUOYANCY

Float Type External Cage Tuffy® Modulevel® Top Mount


Top Mount Float Type Float Type Model E3 Displacer Displacer Type
Level Switch Level Switch Level Switch Level Transmitter Level Switch
Description: A simple and Description: A highly reliable Description: A compact, Description: Advanced Description: Highly reliable
reliable float switch designed level switch in an external cage highly reliable level switch displacer/range spring actu- one-, two- or three-stage level
for top mounting on virtually and designed to be mounted designed for horizontal mount- ated intrinsically safe two-wire switches offering wide and
any process or storage vessel. outside the process vessel. ing into a process vessel or an transmitter. narrow level differentials.
external cage.

Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle: Measurement Principle:
Buoyancy Buoyancy Buoyancy Buoyancy/Range Buoyancy
Spring/LVDT

Applications: Applications: Applications: Applications: Applications:


Virtually any tank or vessel; Clean liquids or interface in Clean liquids or interface in Feedwater heaters, scrubbers, Foaming, surging or agitated
condensate receivers, cooling scrubbers, feedwater heater, virtually any tank or vessel, receivers, separators, boilers, liquids, dirty or clean liquids,
towers, interface detection flair pots, day tanks, accumula- including storage tanks and condensate drip pots, interface heavy oils or slurries in sumps,
tors, knockout drums, etc. process vessels measurement storage tanks or process
vessels, overfill prevention

Features: Features: Features: Features: Features:


• Single or tandem float con- • Sealed or flanged float cages • Available in narrow and wide • No calibration required • Field-adjustable levels and
figurations • Pressures to 3700 psi adjustable differential models • Range spring suppresses differential
• Rugged reliability (255 bar) and temperatures • Float and trim parts in 316 effects of turbulence • Variety of displacer, cable
• Wide selection of switches over +1000 °F (+540 °C) SS or Hastelloy C • Pressures to 5150 psi and wetted parts materials
• Actuating depths of up to • Single or multiple actuation • Pressures to 2630 psi (355 bar); +850 °F (+450 °C) • Ease of installation
48" (1219 mm) levels (181 bar) and temperatures non-steam applications; • Variety of narrow and wide
• Simple operation • Carbon steel or stainless to +900 °F (+482 °C) +800 °F (+425 °C) level differential
• Maintenance-free steel cage materials • Explosion proof enclosure steam applications combinations
• Variety of process • Floats for SGs as low as 0.32 with variety of agency • HART® or Foundation fieldbus • Suitable for use in liquids
connections approvals compatible with SG from 0.40 to 2.40
• Ease of wiring in enlarged • Field-selectable fault signal,
switch housing 3.6 or 22 mA, or HOLD
• SIL 2/3 Certified
• Advanced self-check and
diagnostics

Options: Options: Options: Options: Options:


Single or tandem units, tank Electric or pneumatic switches, Pneumatic switch model, Pneumatic models, ASME Proof-er® ground-checker,
connection type and float size, ASME B31.1, B31.3 or NACE ASME B31.3 or NACE B31.1, B31.3 or NACE floating rooftop/liquid dual
NACE construction, electric or construction, exotic materials construction, wide variety of construction PACTware for detection, extended displacer
pneumatic switch mechanisms, of construction, wide variety of process connections, cast iron enhanced configuration and cable, customer specific levels
guide cages process connections and aluminum switch housings trending capabilities and differential arrangements,
pneumatic or electric switches
CAPACITANCE VISUAL INDICATION MAGNETOSTRICTIVE

OES-100

ORS-300

Kotron® Atlas™ Aurora® Gemini™ Jupiter®


Model 805 Magnetic Level Magnetic Level MLI with Modulevel Model JM4 Magneto-
Smart Transmitter Indicator Indicator Instrumentation Bridle strictive Transmitter
Description: High per- Description: The standard, Description: Unique combi- Description: Unique, fully Description: Highly accurate
formance, loop-powered, high-performance magnetic nation of magnetic level indi- customized design of Modular level measurement device
4–20 mA, RF Capacitance level indicator suitable for cation with guided wave radar Instrumentation Bridle (MIB) that can be directly inserted
transmitter. a wide range of process results in a truly redundant into a tank or externally
designed to best incorporate
conditions. level control instrument. mounted to any one of our
different instrumentation MLIs.
packages and maximize
performance to reduce total
Measurement Principle: Measurement Principle: Measurement Principle: cost of ownership (TOC). Measurement Principle:
RF Capacitance Buoyancy, magnetic coupling Buoyancy, magnetic coupling Time-of-flight measurement
and micropower impulse utilizing a magnetostrictive wire
radar which interacts with a float

Applications: Applications: Applications: Applications: Applications:


Clean or dirty liquids, viscous Feedwater heaters, boilers, Feedwater heaters, vacuum Feedwater heaters, boilers, Separators, surge tanks, gas
slurries oil-water separators, flash tower bottoms, alkylation oil-water separators, flash chillers, bio-therapeutics,
drums, surge tanks, gas units, oil-water separators, pharmaceuticals, process
drums, surge tanks, gas
chillers deaerators, boiler drums vessels and more
chillers, etc.

Features: Features: Features: Features: Features:


• Two-wire, loop-powered • Broad range of chamber • True redundancy through • Refer to ORI-210 brochure • Full graphic local user
• 2-line × 8-character liquid configurations use of two independent for details. interface and local
crystal display • Fabricated non-magnetic technologies • True redundancy through waveform capture
• HART® Communications chambers • Reveal™ wide view indicator use of two independent • 4-20 mA output
• Proven RF technology • ASME and EN flanges • Built to ASME B31.1, B31.3, technologies • Rotatable and Removable
• Precision manufactured PED, ASME U, UM, S Stamp, transmitter head
float NACE construction available • Ergonomic dual
• Flag or shuttle type • All metallic pressure compartment enclosure
indicator boundary materials • Simple set-up and
• Reveal™ wide view indicator • Pressures to 4500 psi configuration
(310 bar) • Smart Probe technology
• SGs as low as 0.25 • Easy attachment to an
• Temperatures to +800 °F MLI or modular bridle
(+425 °C) instrumentation
• Direct insertion for a wide
variety of vessels and
applications
Options: Options: Options: Options:
n/a Custom span, process Remote mounted electron- Full customization Options:
connections, scale units of ics, custom span, process HART® or Foundation fieldbus™
measure, high temperature connections, scale units of communications; Hastelloy®
and cryogenic insulation, measure, high temperature or Monel® materials of
clamp-on reed, micro and and cryogenic insulation, construction; Threaded or
pneumatic switches clamp-on reed, micro and flanged process connections;
pneumatic switches External Jupiter® models can
be top- or bottom-mounted
to an MLI
REAL WORLD SOLUTIONS

Magnetrol® designs, manufactures, markets and services level and


flow instrumentation for the process industries worldwide

Crude Oil Natural Gas Petroleum Refining Chemical

Power Generation Nuclear Power Water & Wastewater Renewable Energy

Life Science Food & Beverage Pulp & Paper


Ch e CORPORATE HEADQUARTERS & MANUFACTURING FACILITY
ck
ma
gn 705 Enterprise Street
etr
ol. Aurora, Illinois 60504-8149 USA
co
m Tel: +1-630-969-4000 – Fax: +1-630-969-9489
fo
ry e-mail: info@magnetrol.com
ou
rl

oc
EUROPEAN HEADQUARTERS & MANUFACTURING FACILITY

al
Heikensstraat 6

M
ag
9240 Zele, Belgium

ne
tro
Tel: +32-(0)52-45.11.11 – Fax: +32-(0)52-45.09.93

l/
e-mail: info@magnetrol.be

Or
ion
Ins
CHINA MANUFACTURING FACILITY

trum
Plant 6, No. 191, Huajin Road Minhang District, Shanghai, China
Tel. +86-21-6249-1350 – Fax: +86-21-6249-1351

ents
e-mail: shanghai@magnetrol.com

repre
UAE MANUFACTURING FACILITY

sentativ
PO Box 261454 - LIU FZS1-BA03
Jebel Ali Free Zone (JAFZA), Dubai, United Arab Emirates

e.
Tel: +971 4 8806345 – Fax: +971 4 8806346
info@magnetrol.ae

ORION INSTRUMENTS MANUFACTURING FACILITY


2105 Oak Villa Blvd.
Baton Rouge, LA 70815
Tel: +1-225-906-2343 – Fax: +1-225-906-2344
info@orioninstruments.com

magnetrol.com
orioninstruments.com

41-114.18

© 2020 Magnetrol® International, Inc.


Magnetrol® and Magnetrol® logotype are registered trademarks of Magnetrol® International, Inc.

You might also like