Download as pdf
Download as pdf
You are on page 1of 1
Indian Calibration Services ‘An Exclusive House for Validation & Calibration of Analytical Instruments 304 & 313, Laxmi Deep, District Centre, Near Nirman Vihar Metro Station, Laxmi Nagar, Delhi-110092 Phone / Fax: (011) 22453259, 22434362, 9599482307 iancalibrationservices@ gmail.com Website : wwww.multitechis.com CALIBRATION CERTIFICATE Page 1 of CALIBRATION CERTIFICATE OF DIGITAL THERMO-HYGROMETER : E-mail Certificate No: ‘22100004764 Issued On: | 15/03/2022 [ULR No: C214622100004761F | Calibration Date: 14/03/2022 Job Identification No: _ | ICS/C/T/03/4761 Next Calibration Date: | 13/03/2023 [Ref. No: | SRF- Dated: 10/03/2022 ‘Mis Manjula Laboratories, CALIBRATED FOR: 13-8, Friends Industrial Estate, Focal Point, Ludhiana ~ 141070. a EQUIPMENT DESCRIPTION Name Digital Thermo-Hygrometer Make/Model | HTC-1 Visual inspection _| Ok Serial No. - 1D. No. [-THM-02 [Range ~50°C to 70°C] 10 % to 90% (RH)_| Least Count 0.1°C/1% RH Location Calibration Site | In-Lab jact E ENVIRONMENTAL CONDITIONS [Temperature 2.0°C#3.0°C | Humidity 50£10%RH ‘STANDARD REFERENCE DETAILS Traceable to National / International Standard Name of the fi Calibration Dato of | standard Make. Certificate No. | agencyiTraceability | Calibration | Digital Temp: Pal Indicator with “Lutron” 22100000001 Indian Calibration | oworvzo22 | 01012023 Sensor i Temp. & Hum. ind. | ; ETL/ATOSRAICIFT sorar021 es Rotronie 506 FRI, Kerala. | S0/"2/202) "| oason/2023 USED EQUIPMENT DETAILS Environmental Chamber PRINCIPLE/METHODOLOGY OF | As per Calibration Procedure No.: ICS/CALISOP-THOS (ITS-80) CALIBRATION. (Comparison Method) RESULTS: Thermal Calibration (On Working Range) = i : Corrected Value of Standard | Uncertainty at approx 95% C.L and Ue, eee (ava.) ‘coverage factor k=2 [Temperature | Humidity [Temperature [Humidity Temperature Humidity 16.0°C 20% RH 14.93°C 20.74 %RH £037°C 16 %RH 40% RH 19.90°C 41.13 %RH £037°C 216% RH 75% RH 29.86°C 76.50 96RH $0.43°C = 1.6% RH 90% RH 39.83°C | 91.88 %RH #0436 | £1.6%RH Valid up to REMARKS: The recommended date for next calibration is mentioned, as asked by the customer. **° END OF REPORT##* The sabe rob ar atonal wane Cael Lav and oul nd nda Far and on borat stint ete pr Indian Caliration Services et ce srg nd aye pater Ensen opis aie erro inpd "a ty cow eer ime Ube ce ovort Sard it seo pe am a el arson Cte es dn pee os ince on oct er Caren sean se Pen ote en Sat=4 Raises! Tiectuto cease bred eC tne nr st einer, _ Checked by

You might also like