Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES:

1. ALL DIMENSIONS AND LEVELS SHALL


BE AS PER ARCHITECTURAL IN ( mm )

2. COLUMNS BELOW GROUND THE CONCRETE


850 25 25 COVER EXPOSED TO SOIL SHALL BE ( 40mm )

3. COLUMNS ABOVE THE GROUND LEVEL THE


100 CONCRETE COVER SHALL BE ( 30mm )

4. SOIL SHALL BE PROPERLY COMPACTED


AT PASSING DRY DENSITY OF 98 %

5. CONCRETE BEAMS BELOW GROUND LEVEL


1000 4500 EXPOSED TO SOIL THE CONCRETE COVER
RISER

SHALL BE ( 35mm )
STEP

TIE BEAM TB-01 6. CONCRETE BEAMS ABOVE GROUND LEVEL


THE CONCRETE COVER SHALL BE ( 25mm)

1200
7. CONCRETE SLAB AT GROUND LEVEL THE
CONCRETE COVER SHALL BE ( 75mm )
RISER
STEP

ROOF FLOOR SLAB ROOF FLOOR SLAB


8. CONCRETE SLAB ABOVE GROUND LEVEL
@ SSL + 7.50m @ SSL + 7.50m GROUND FLOOR THE CONCRETE COVER
SHALL BE (25mm )

9. CONCRETE FOOTING THE CONCRETE COVER

1000
RB-6 RB-6 RB-6 SHALL BE ( 75mm )
200

ST-02 CONC. SLAB


TREAD 10. CONCRETE:
(A) - COLUMNS/FOOTINGS/BEAMS BELOW
GROUND LEVEL THE CONCRETE

0
MIX DESIGN = CLASS A ( 1: 2: 3)
RISER

30
STEP

3500

3550

3550
1400
(B) - COLUMNS/BEAMS/SLABS ABOVE THE
GROUND LEVEL THE CONCRETE MIX
DESIGN = CLASS B ( 1: 3: 4 )

0
20
(C) - CONCRETE SUSPENDED SLAB AT WET
150 AREAS (ROOF/TOILETS & BALCONY )
RISER
STEP

THE CONCRETE MIX DESIGN = CLASS B


PLUS WATERPROOF CEMENT ( NEVADA

1000
OR SAHARA WHITE CEMENT )
1F FLOOR SLAB 1F BALCONY FLOOR (D) - CONCRETING OF ROOF SLABS; TOILETS
@ SSL + 4.00m SLAB @ SSL + 3.95m BALCONY SHALL BE CONTINOUS FOR A
CONCRETING, NO CONSTRUCTION JOINT
975 25 CONC. LEDGE SHALL BE MADE AT SITE WITH PROPER
COMPACTION AVOIDING COLD JOINT IN
FB-6 FB-3 FB-3 FB-3 CANOPY THE SLAB.

RISER
(E) - CONSTRUCTION AND IMPLEMENTATION
A. (ST-02) STRINGER BEAM CROSS SECTION S. (ST-02) STAIRCASE SECTION B-B IF FOUND CONFLICT OR OBSTRUCTION
SCALE: AS SHOWN
SCALE: AS SHOWN SHALL BE MODIFIED DURING THE SITE
WORKS BY THE CONTRACTOR'S AND TO
BE OR SHALL BE NOTIFIED THE CLIENT
PRIOR TO PROCEED CHANGES AT SITE.

LEGEND:

COLUMNS CONTINUES TO THE UPPER FLOOR

COLUMNS TERMINATED FROM UPPER FLOOR

CONCRETE HOLLOW BLOCK CHB

S. STAIRCASE (ST-02) DETAIL-2


S2=200 CONCRETE SLAB THICKNESS
SCALE: AS SHOWN
REINFORCED CONCRETE OTHER TYPE

REINFORCED CONCRETE

GB GROUND BEAM CONCRETE

FB FIRST FLOOR CONCRETE BEAM

RB ROOF FLOOR CONCRETE BEAM

PB PENTHOUSE ROOF CONCRETE BEAM


4500 4500 2000 850 25 25
C CONCRETE COLUMNS
100
1740 2760
F CONCRETE FOOTINGS

1540 1200 1560


WFT CONCRETE WALL FOOTING

ROOF FLOOR SLAB ROOF FLOOR SLAB


@ SSL + 7.50m @ SSL + 7.50m PC PLANTED CONCRETE COLUMNS

RISER
150

STEP
RB-1 RB-6
RB-1 STF STIFFENER CONCRETE COLUMNS

TB CONCRETE TIE BEAMS

200
3500

3550

ST-02 CONC. SLAB

C-SLAB CONCRETE CANTILEVER SLAB

WC CONCRETE WALL COLUMNS


1F FLOOR SLAB 1F BALCONY FLOOR
@ SSL + 4.00m SLAB @ SSL + 3.95m CONCRETE LINTEL BEAM TO ALL
313

FB-1 FB-1 LINTEL-BEAM OPENINGS ABOVE DOORS AND


FB-6 CONC. LEDGE
CANOPY WINDOWS

S. (ST-02) STRINGER BEAM DETAIL-1


150
D DOOR
SCALE: AS SHOWN
W WINDOW
S. (ST-02) STRINGER BEAM SECTION A-A
SCALE: AS SHOWN
WALL MOUNTED EXHAUST FAN

PROJECT TITLE : CLIENT: SHEET CONTENTS : DESIGNED BY : K2A_CE SHEET NO. 09


ENGR. KEMAL A. ANDALAN CHECKED BY : K2A_CE
ARCHITECTURAL / STRUCTURAL BUTCH P. FAJARDO
REG. NO.
ARCHITECT
TIN.
PLACE :
KEMAL A. ANDALAN
ENGINEER

REG. NO. PRC # 0066139


PTR.
PROPOSED 2 - STOREY HOUSE + PENTHOUSE OWNER
K2A STAIRCASE-02 SECTION DETAILS REINFORCEMENT BAR'S &
STRINGER BEAM SECTION DETAILS REINFORCEMENT BAR'S
CAD BY : K2A_CE
A/S R-0
PTR. DATE : DATE :
ZAMBOANGA CITY, PHILIPPINES ZAMBOANGA CITY, PHILIPPINES
DATE : 30/SEPT/2015 PROJECT NO. B050667
IAPOA NO. TIN. PLACE :

You might also like