NOTES:

5200 575
1. ALL DIMENSIONS AND LEVELS SHALL
425
BE AS PER ARCHITECTURAL IN ( mm )
9700 9700 2000
9700 2. COLUMNS BELOW GROUND THE CONCRETE
4500 5200 1000 4500 5200 450 COVER EXPOSED TO SOIL SHALL BE ( 40mm )
4500 5200

150

150
125
500 1700 375 1700 3. COLUMNS ABOVE THE GROUND LEVEL THE
100
350
CONCRETE COVER SHALL BE ( 30mm )
300

2601

2450
525
350
450 4. SOIL SHALL BE PROPERLY COMPACTED

3125
3075
125
700 350
395
AT PASSING DRY DENSITY OF 98 %

4500

4500
525
5. CONCRETE BEAMS BELOW GROUND LEVEL

1700

675
EXPOSED TO SOIL THE CONCRETE COVER

100
SHALL BE ( 35mm )
3480

1700

6875
4500

4500

2050
350
350

4500

4500

1375

1375
4500

4500
630
6. CONCRETE BEAMS ABOVE GROUND LEVEL
THE CONCRETE COVER SHALL BE ( 25mm)

4425
525

1700

1900
7. CONCRETE SLAB AT GROUND LEVEL THE
475

1700

1700
450 CONCRETE COVER SHALL BE ( 75mm )

2375
9000

350

450

150
100

9000

9000
350
8. CONCRETE SLAB ABOVE GROUND LEVEL

400

675
11000
525

350

450
ST-02 GROUND FLOOR THE CONCRETE COVER

100
11000

11000
SHALL BE (25mm )
650 1350 845 2177.5 2177.5 75

1700
2000 5200 650 9. CONCRETE FOOTING THE CONCRETE COVER
4500

4500
4350
SHALL BE ( 75mm )

4500

4500

4500

4500
7850
525 10. CONCRETE:
ST-02 (A) - COLUMNS/FOOTINGS/BEAMS BELOW
S. ABOVE PENTHOUSE FLOOR CEILING CONCRETE LEDGE CANOPY PLAN GROUND LEVEL THE CONCRETE
SCALE: 1:100 MTRS MIX DESIGN = CLASS A ( 1: 2: 3)

450
650
500

100 125

150
(B) - COLUMNS/BEAMS/SLABS ABOVE THE

650

425
500

400
2000

4700 GROUND LEVEL THE CONCRETE MIX

2000

2000

2000

2000
4700 DESIGN = CLASS B ( 1: 3: 4 )
2000

5075 150
12mm Dia (T+B)

2000
(C) - CONCRETE SUSPENDED SLAB AT WET
525

AREAS (ROOF/TOILETS & BALCONY )


@ 150mm C/C

650

400
650 4550 150 THE CONCRETE MIX DESIGN = CLASS B
1650 2850 5200
PLUS WATERPROOF CEMENT ( NEVADA
650 650 4550 150
150 4500 150 5050 OR SAHARA WHITE CEMENT )
1000 4500 5200
S. ROOF FLOOR CONCRETE LEDGE CANOPY PLAN (D) - CONCRETING OF ROOF SLABS; TOILETS
S. ABOVE GROUND FLOOR CEILING CONCRETE LEDGE CANOPY PLAN 11050 SCALE: 1:100 MTRS
RC BALCONY SHALL BE CONTINOUS FOR A
SCALE: 1:100 MTRS CONCRETING, NO CONSTRUCTION JOINT
COLUMN SHALL BE MADE AT SITE WITH PROPER
S. ABOVE FIRST FLOOR CEILING CONCRETE LEDGE CANOPY PLAN COMPACTION AVOIDING COLD JOINT IN
100 100 100 SCALE: 1:100 MTRS THE SLAB.

125
1500 2000
(E) - CONSTRUCTION AND IMPLEMENTATION
IF FOUND CONFLICT OR OBSTRUCTION
100

SHALL BE MODIFIED DURING THE SITE


500 5200 WORKS BY THE CONTRACTOR'S AND TO
BE OR SHALL BE NOTIFIED THE CLIENT
co co PRIOR TO PROCEED CHANGES AT SITE.
MH MH
2300
2000

500

TOP @ SSL + 11.30m

125

300
PR @ SSL + 11.00m 1425 5200 475
CONC. LEGEND:

150
750
125 325
CANOPY

2300

DETAIL- 4
100

WATER WATER
10 mm dia @ 200 mm c/c both ways TANK-2 TANK-1
TYPICAL CONC. CANOPY DETAIL-6 COLUMNS CONTINUES TO THE UPPER FLOOR

150
150
3000 T.O.P. @ SSL + 8.70m
125

SCALE: AS SHOWN

1200

DETAIL- 4
TB-01

1350

2700
2550
ROOF @ SSL + 7.50m
COLUMNS TERMINATED FROM UPPER FLOOR

275
150

400
SEPTIC TANK LAYOUT PLAN
350 150
125 125

600
SCALE: AS SHOWN DETAIL-3 DETAIL-3

4500

4500
525
DETAIL-3 DETAIL-3
CONCRETE HOLLOW BLOCK CHB

1500

3500

6925
1950
SEPTIC TANK TOP SLAB THE REINFORCEMENT SHALL BE
ROOF WATER TANK COCNRETE BASE PLAN / DETAILS 350
125

10 mm DIAMETER BAR'S @ 200mm C/C SPACING AT BOTH


SCALE: AS SHOWN S2=200 CONCRETE SLAB THICKNESS
1000

WAYS DIRECTION.
BACKFILLING BACKFILLING

4225
GROUND LINE co co GROUND LINE 1F @ SSL + 4.00m 350
100

275
400
125 125

Space
400

Air REINFORCED CONCRETE OTHER TYPE


700

DETAIL-3
2275

2275
Water Line
Water Line 525

150
1500

3600

350
2250

REINFORCED CONCRETE

100
LEACHING WELL DIGESTIVE CHAMBER

DETAIL-3
RC CONCRETE WALL 100 1900 5200
125

VERT. BAR'S 10mm @

125
400 1000

250mm C/C SPACING


HOR. BAR'S 10mm @
SLAB =125 mm THK 250mm C/C SPACING GF @ SSL + 0.40m GB GROUND BEAM CONCRETE
150

150 300
S. PENTHOUSE ROOF CONCRETE LEDGE CANOPY PLAN
400

NGL @ SSL + 0.00m


250

2750 SCALE: 1:100 MTRS

10 mm Dia BAR'S @
2550 FB FIRST FLOOR CONCRETE BEAM
300 300 200 mm c/c both ways

475
CHB WALL FRONT ELEVATION
SEPTIC TANK LONGITUDINAL SECTION SCALE: 1:100 M RB ROOF FLOOR CONCRETE BEAM
SCALE: AS SHOWN

PB PENTHOUSE ROOF CONCRETE BEAM

4500 5200
C CONCRETE COLUMNS
2000 4500 4500
150 1400 475
DETAIL 4
1800 2575 1925

TOP @ SSL + 11.30m


350 1550 150

TOP @ SSL + 11.30m


250 F CONCRETE FOOTINGS
1000
300

300
300

300

300

PR @ SSL + 11.00m PR @ SSL + 11.00m


150

DETAIL-6

TB-01 TB-01 TB-01


TB-01

TB-01 TB-01
P. HOUSE ROOF CONC. LEDGE CANOPY DETAIL-3 WFT CONCRETE WALL FOOTING
2300

2300
2300

2300

LINTEL BEAM
SCALE: AS SHOWN
CEILING HEIGHT

TB-01
CLEARANCE
2925

(2800)

T.O.P. @ SSL + 8.70m T.O.P. @ SSL + 8.70m


1100 100
125

TB-01 TB-01
PC PLANTED CONCRETE COLUMNS
1200
1200

TB-01 TB-01
ROOF @ SSL + 7.50m ROOF @ SSL + 7.50m
200
275

400
125

STF STIFFENER CONCRETE COLUMNS


TB-01
3300

TB-01
CEILING HEIGHT
CEILING HEIGHT

CLEARANCE

3500
CLEARANCE

3500

3550

(2800)
(2800)

2500
2500

TB CONCRETE TIE BEAMS


300
1450

500
500

1F @ SSL + 4.00m 1F @ SSL + 4.00m


850
200
50

200
200

225

400
125

C-SLAB CONCRETE CANTILEVER SLAB


TB-01 TB-01
CEILING HEIGHT
CEILING HEIGHT
200

150 150
CLEARANCE
CLEARANCE

3600
3600

3550
3550

3200

(3000)
(3000)

WC CONCRETE WALL COLUMNS


2600

2200
20
0

GF @ SSL + 0.40m GF @ SSL + 0.40m CONCRETE LINTEL BEAM TO ALL


50

LINTEL-BEAM OPENINGS ABOVE DOORS AND


400

400
400

400

CHB CHB CHB NGL @ SSL + 0.00m CHB CHB CHB NGL @ SSL + 0.00m
400

GB GB GB GB GB GB GB WINDOWS
250
1000

300 1000

300 1000

300 1000

WFT
1300

WFT WFT
400
BOTTOM OF FOOTING
D DOOR
300

300

LEVEL @ SSL - 1.30m


100

100
75

75

75

75

75
1500
1500

1500

POST TIMBER PILES


TOE OF TIMBER PILE
LEVEL @ SSL - 2.80m
POST TIMBER PILES
250 W WINDOW

S. RIGHT ELEVATION SECTION A-A S. FRONT ELEVATION SECTION B-B


SCALE: AS SHOWN SCALE: AS SHOWN
P. HOUSE ROOF CONC. PARAPET WALL DETAIL-4 WALL MOUNTED EXHAUST FAN

SCALE: AS SHOWN

PROJECT TITLE : CLIENT: SHEET CONTENTS : DESIGNED BY : K2A_CE SHEET NO. 04


ENGR. KEMAL A. ANDALAN CHECKED BY : K2A_CE
ARCHITECTURAL / STRUCTURAL
REG. NO.
BUTCH P. FAJARDO
ARCHITECT
TIN.
KEMAL A. ANDALAN

REG. NO. PRC # 0066139


ENGINEER
PTR.
PROPOSED 2 - STOREY HOUSE + PENTHOUSE OWNER
K2A ABOVE GROUND FLOOR CONCRETE LEDGE CANOPY PLAN; ABOVE FIRST FLOOR CONCRETE LEDGE CANOPY PLA; ROOF
FLOOR CONCRETE LEDGE CANOPY PLAN; ABOVE PENTHOUSE FLOOR CONCRETE LEDGE CANOPY PLAN & PENTHOUSE
HOUSE ROOF CONCRETE LEDGE CANOPY PLAN; SEPTIC TANK LAYOUT PLAN; SEPTIC TANK SECTION DETAIL AND ROOF
WATER TANK CONCRETE BASE PLAN & DETAIL; CHB WALL FRONT ELEVATION; RIGHT ELEVATION SECTION A-A; FRONT
CAD BY : K2A_CE
A/S R-0
PTR. DATE : PLACE : DATE :
ZAMBOANGA CITY, PHILIPPINES
ELEVATION SECTION B-B; PENTHOUSE ROOF CONCRETE LEDGE CANOPY DETAIL 3; PENTHOUSE ROOFPARAPETDETAIL4 DATE : 30/SEPT/2015 PROJECT NO. B050667
IAPOA NO. TIN. ZAMBOANGA CITY, PHILIPPINES
PLACE :