WiAAPS Quick Guide Page #1

Overview WiAPB
Warranty void if WiAPB is installed upside down
Using WiAPC and Termination Board to provide power to WiAPBs

WiAPC/Termination board powers WiAPBs from inside the cabinet


Place antenna on side of cabinet with line of sight to
Located inside cabinet intersection where wireless APBs are located

WiAPC Wireless
Communications

Pole
WiAPB
Termination board Field Wires 18V AC
18V AC Used for power only

For WiAPC wiring


connections see page#2

Note: WiAPC provides 18V AC to the termination board.


WiAPB

Cabinet WiAPB Base Station


(Close up view of terminal block in front)
✓ WiAPC places calls into the traffic controller.
• 9-Pin cable needs to be installed from the WiAPC to the
USB
terminals of the PED CALLS in the cabinet. (9-Pin cable
included)
✓ Utilizes the existing or new Field Wires from cabinet to WiAPB
Field Terminals (FT)
pedestrian push buttons. (For power only).
• Connect the Field Wires from the cabinet onto the
termination board.
✓ Termination Board: It is recommended, for troubleshooting Existing or new
purposes to use the “A” terminals for power and “B” field wires
terminals as common. Also use termination board slot #1 To termination WiAPB wiring connections 18V AC
for WiAPB ”1”, slot #2 for WiAPB “2”, and so on for all the board for power Not polarity dependent
push buttons.

NOTE: For NEW intersection installations, Campbell Company recommends IMSA
14 Gauge (loop detector wire)
Doc # 906-0034 Rev A

For complete documentation visit http://www.pedsafety.com/product-installation-guides/ ©Campbell Company 2017 Tech Support: (208) 345-7459, option 2
WiAAPS Quick Guide
Cabinet wiring
Page #2
Terminals for Walk and Don’t Walk (120 V AC) in the cabinet
WiAPC
Φ2 PED Φ4 PED Φ6 PED Φ8 PED
Default IP: 192.168.1.101
Username: admin Antenna used for wireless communication
120 V
Neutral DW W DW W DW W DW W Password: password

DB25 APC Input Cable (120 Volts) Φ PED


Label Pin Color
1
16 AWG 120 V
Blue/White Stripe
Neutral } White } Terminals of the PED Calls (Low Voltage) in the cabinet
14 White/Black Stripe Neutral
W8 3 White/Red Stripe 22 AWG W Φ8 APB Power COM Ped Logic
Push buttons GND Φ8 Φ6 Φ4 Φ2
W7 16 Ora nge/Bla ck Stripe 22 AWG W Φ7
W6 4 Green/Bla ck Stripe 22 AWG W Φ6
Some cabinets require
W5 17 Blue/Bla ck Stripe 22 AWG W Φ5 a Jumper to be
installed between the
W4 5 Red/Green Stripe 22 AWG W Φ4 Grounds on the
W3 18 Green 22 AWG W Φ3 terminals of the ped
calls.
W2 6 Blue/Red Stripe 22 AWG W Φ2
W1 19 Red/White Stripe 22 AWG W Φ1
DW 8 7 Ora nge/Red Stripe 22 AWG DW Φ8
18 V AC DB9 APC Output Cable Φ PED CALL
DW 7 20 Red 22 AWG DW Φ7
Alternate
DW 6 8 Red/Bla ck Stripe 22 AWG DW Φ6 Label Pin Color Color
PH1 1 Ora nge/Bl a ck Stri pe 22 AWG Ora nge Φ1
DW 5 21 Bla ck/White Stripe 22 AWG DW Φ5
PH3 2 Red 22 AWG Red Φ3
DW 4 9 White 22 AWG DW Φ4 PH5 3 Whi te 22 AWG Whi te Φ5
DW 3 22 Blue 22 AWG DW Φ3 PH7 4 Bl a ck 22 AWG Bl a ck Φ7
Field COM 5 Green 22 AWG Green COM Ped Push Button
DW 2 10 Bla ck 22 AWG DW Φ2
PH2 6 Green/Bl a ck Stri pe 22 AWG Brown Φ2
DW 1 23 Green/White Stripe 22 AWG DW Φ1
Terminals
PH4 7 Red/Bl a ck Stri pe 22 AWG Purpl e Φ4
to power PH6 8 Whi te/Bl a ck Stri pe 22 AWG Yel l ow Φ6
WiAPBs PH8 9 Bl ue 22 AWG Bl ue Φ8
Stations Termination Board NA Ora nge NA Grey NA
For complete documentation visit http://www.pedsafety.com/product-installation-guides/ ©Campbell Company 2017 Tech Support: (208) 345-7459, option 2
WiAPC WiAAPS Wiring Guide
Default IP: 192.168.1.101 Recommended setup Page #3
Username: admin
Password: password

WiAPB 5 WiAPB 6 WiAPB 7 WiAPB 8


Wireless
Communication

WiAPC input
120V AC APB Power Place antenna on side of cabinet with
uses 25-pin line of sight to intersection where
conductor wireless APBs are located
cable
HIGH VOLTAGE 5
6
7
8
WiAPC output
Termination Board: It is recommended, for troubleshooting purposes to use the “A” terminals
low voltage connection
for power and “B” terminals as common. Also use termination board slot #1 for WiAPB ”1”,
uses 9-pin conductor
slot #2 for WiAPB “2”, and so on for all the push buttons. Stations are not polarity dependent.
cable
18 V AC Termination Board
Each WiAPB must have a unique ID number; Phases can be assigned to multiple WiAPBs.
Programming will be necessary to assign ID numbers and Phases to each WiAPB Station from
Utilizes the existing or new Field Wires
the WiAPC.
from cabinet to pedestrian push buttons
(for power only). Connect the Field Wires 4
from the cabinet on to the termination 3
board. 2 5
1
WiAPB 1
P6 = Phase 6

If the system was preprogrammed


by Campbell Company, please use
the WiAAPS Worksheet Map for
proper placement for each station.

WiAPB 1 WiAPB 2 WiAPB 3 WiAPB 4


WiAPB 6
P8 = Phase 8 Recommended field wire for WiAAPS new installations: IMSA 14 AWG (loop detector wire)
Sample picture use as a reference only Warranty Void if WiAPB is installed Upside Down

For complete documentation visit http://www.pedsafety.com/product-installation-guides/ ©Campbell Company 2017 Tech Support: (208) 345-7459, option 2