Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PROJECT: SEPTIC VAULT w/ THREE CHAMBERS NAME: P. R.

ALVAREZ
SUBJECT: CE 423- CONSTUCTION METHODS and MANAGEMENT SHEET: 1

SEPTIC VAULT DIMENSIONS:


L= 3.1 M TOTAL LENGTH OF SEPTIC VAULT
W= 1.6 M TOTAL WIDTH OF SEPTIC VAULT
D= 1.5 M TOTAL DEPTH OF SEPTIC VAULT

FOR SLAB FLOORING:


LSF= 3.1 M LENGTH OF SLAB FLOORING
WSF= 1.6 M WIDTH OF SLAB FLOORING
tSF= 0.1 M THICKNESS OF SLAB FLOORING

VSF= L x W x t
VSF= 0.50 cu. M VOLUME OF SLAB FLOORING

FOR SEPTIC VAULT COVER:


LSC= 3.1 M LENGTH OF SEPTIC VAULT COVER
WSC= 1.6 M WIDTH OF SEPTIC VAULT COVER
tSC= 0.1 M THICKNESS OF SEPTIC VAULT COVER
SLAB OPENING:
LOPENING= 0.4 M LENGTH OF MANHOLE
WOPENING= 0.6 M WIDTH OF MANHOLE
QTTYMANHOLE= 3 pcs no. OF MANHOLES
AOPENING= 0.72 sq. M TOTAL AREA OF OPENINGS

VSC= (L x W x t) - (AOPENING x t)
VSC= 0.42 cu. M VOLUME OF SEPTIC VAULT COVER
FOR WALLS & PARTITIONS:
WALL DIMENSION
L= 3.1 M LENGTH OF SEPTIC VAULT
W= 1.6 M WIDTH OF SEPTIC VAULT
D= 1.5 M DEPTH OF SEPTIC VAULT
tSF= 0.1 M THICKNESS OF SLAB FLOORING
tW= 0.1 M THICKNESS OF SEPTIC VAULT COVER
tSC= 1.1 M THICKNESS OF WALLS & PARTITIONS
Dw= 1.3 M DEPTH OF WALLS & PARTITIONS

FOR LONGITUDINAL WALL


QTTYLW= 2 pcs no. OF LONGITUDINAL WALLS
VLW= L x DW x QTTYLW * TW
VLW= 0.806 cu. M VOLUME OF LONGITUDINAL WALLS

FOR TRANSVERSE WALLS & PARTITIONS


QTTYTW= 4 pcs no. OF LONGITUDINAL WALLS
VTW= W x DW x QTTYLW * TW
VTW= 0.832 cu. M VOLUME OF LONGITUDINAL WALLS

ESTIMATING CONCRETE WORKS


VC= VLW+VTW+VSF+VSC
VC = 2.56 cu. M TOTAL VOLUME OF CONCRETE

ESTIMATION OF MATERIALS
CLASS A CONCRETE MIXTURE
nC= 24 BAGS CEMENT NEEDED
VS= 1.5 CU. M VOLUME OF SAND
VG= 3 CU. M VOLUME OF GRAVEL
VW= 144 GAL VOLUME OF WATER

SUMMARY OF CONCRETE WORKS

QNTY UNIT MATERIAL DESCRIPTION UNIT COST TOTAL COST


24 BAGS PORTLAND CEMENT TYPE 1-P (NORTHERN) 250 6000
1.5 CU. M CRUSHED SAND 1000 1500
3 CU. M GRAVEL (3/4") 1000 3000
144 GAL DRINKING WATER (ABSOLUTE) 5 720