SPK Profile

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

“Offer the highest quality to customers with my prime directive“

With more than 15 years of experience in the field of electrical testing and commissioning, Mr. Prabakaran has
offered his service and knowledge to all major MNC Companies across Pan India. Mr. Prabakaran has also
worked in many parts of Asia, the Middle East and Africa which made him bring additional stars to his
knowledge and experience. With all these experiences, he started SPK Power in 2015.

As a Director, he has good control and oversees all business operations, people and ventures. Mr. Prabakaran is
a strategist and a leader able to steer the company to the most profitable direction while also implementing its
vision, mission, and long-term goals. Mr. Prabakaran goal is to ensure the SPK Power is constantly moving
towards fulfilling its short-term and long-term objectives and does not diverge from its strategic guidelines.

Mr. Prabakaran holds a Bachelor of Science in Engineering degree from BIRLA INSTITUTE OF TECHNOLOGY AND
SCIENCE, PILANI(BITS). He has 15 years of experience in the field of Engineering, he has gained excellent
expertise in technical skills and possesses great knowledge in the field of Engineering. Mr.Prabakaran through
SPK Power has developed good communication and relationship over time towards all clients and contractors,
which resulted in the best service provider, repetitive business and maintain trust relationships with business
partners and authorities.

SPK Power has built its core capacities in the field of energy-related to sub-station, power plant, renewable
energy, and industrial fields. We have encountered many adversities, but we were able to overcome those
challenges. These situations gave us room for new opportunities and to overcome our limitations. We SPK
Power are staffed with the best technical expertise and with equipped with advanced equipment’s. We have
established a strong foothold as a global leading company that provides the best services throughout the world.
We receive trust and love from customers the people alike. We like to thank the management that is
transparent and honest. We will create an environment, where young people can thrive, remain energetic and
healthy. Ultimately understand their contributions and self-worth within the company.
Experience in Various makes of Numerical & Electro Mechanical Relays...
GE Multilin / MiCOM / ALSTOM / AREVA / SCHNEIDER Relays...
P111, 122, 121,F35,F60 KCGG122,142, CDG&CAG - O/C & E/F Protection.
P127 & KCEG112, 142, 152, 242 - Directional O/C & Protection.
KVFG122, P922, P941 VAG, VDG & DTH - Voltage and Frequency Relays.
P122,P225 & P220 - Motor Protection.
P642, P643,T60, DTH, KBCH - Transformer diff.Protection.
P545, P546 - Line Differential.
P444, P442 - Line Distance Relay.
MiCOM P341, P343, G60,etc.. - Generator Protection.
KAVR100, 130 - Voltage Regulation Relay.
KVTR100 & VRAM - Auto Reclose and Check synchronizing.
KVGC202,KAVS & SKD, SKE - Check Synchronizing Relay.
B90,P743&P746 - Bus bar protection.
VTU - Over Voltage Relay.
MVAJ, MMVAX, MVTT, MVTU - Voltage Operated Relays.
ABB RELAYS...
REF, REJ, SPAJ - O/C & E/F Protection.
REM – 545 / 543 - Motor Protection .
RET, RADSB, SPAD - Transformer Diff.Protection.
RED670 - Line Differential.
REL 670 - Line Distance Protection.
REB500 - Bus Bar Protection.
REC 630 - Multi Function Relay.
REF615 & RADHD - REF Protection.
SPAE, SPAM - Feeder Protection.
REG - Generator Protection.
SPAG, SPAD, SPAF, SPAU, REX, etc...
SIEMENS RELAYS...
7SJ6005, 7SJ6225 - O/C & E/F Protection.
7UM62 & 7UM85 - Motor & Generator protection.
7UT612 - Transformer Diff. Protection.
7SD61, 7SD610 - Line differential protection.
7SA522 - Distance Protection.
7SJ62, 63, 64 - Multi function Relay.
7SS52 & 7SS85 - Bus bar protection.
7SJ8031, 7SJ8032, 7SK8051 & 7SL8081 etc…
NR RELAYS...
PCS 9611 - Feeder Protection Relay.
PCS 9641 & 9641S - Motor Protection Relay.
PCS 978 & 978S - Transformer diff. Protection Relay.
PCS 902 & 931 - Line distance protection.
SEL387 L & 411 L - Line differential relay.
EASUN REYROLLE RELAYS...
TJM10 & 2TJM - Feeder protection relay.
MIT121,131 - Motor protection relay.
MIB, DUOBIAS - Transformer differential relay.
CS – 101 - Line distance relay.
TEB2, RH03, ARGUS1,.
LARSEN & TOUBRO RELAYS...
MV12, MC16A, MC12A, SC14S, MC31A - Feeder protection relay.
MM10 - Motor protection relay.
MD32M - Transformer differential relay.
MD32G - Generator differential relay.
TOSHIBA RELAYS...
GRD140, GRD110, GRE130, GRE140 - Feeder protection relay.
GRE170 - Motor protection relay.
GRD100, GRE160 - Transformer differential relay.
GRE170G - Generator differential relay.
VAMP RELAYS...
VAMP51 - Feeder protection relay.
VAMP40 - Motor protection relay.
VAMP256 - Transformer differential relay.
VAMP210 - Generator differential relay.
SEL RELAYS...
SEL 750, 351,551 & 751 - Feeder Protection Relay.
SEL710 & 849 - Motor Protection Relay.
SEL745 & SEL 487 - Transformer diff. Protection Relay.
SEL321, 421 - Line distance protection.
SEL387 L & 411 L - Line differential relay.
SEL487B - Bus bar protection relay.
400KV/220KV/132KV/33KV Switchyard, Singida, TANZANIA, AFRICA.
400KV Switchyard, Singida.
Testing and Commissioning of 400/220/33 kV 250/250/85 MVA Auto TRANSFORMER- 2 No’s.
Testing and Commissioning of 3Ø, 400/220/33 kV 250/250/85 MVA Shunt Reactor – 4 No’s.
Testing and Commissioning of 400Kv Current Transformer – 27 No’s.
Testing and Commissioning of 400Kv Capacitor Voltage Transformer – 24 No’s.
Testing and Commissioning of 400Kv Circuit Breaker– 15 Set.
Testing and Commissioning of 400Kv Disconnector – 36 Set.
Testing and Commissioning of 400Kv Lightning Arrester – 42 No’s.
Testing and Commissioning of 400Kv Bus Pole Insulator – 136 No’s.
Commissioning of 400Kv Differential & Stability Checked.
Commissioning of 400Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.

220KV Switchyard, Singida.


Testing and Commissioning of 220/33 kV 125/125/41.6 MVA Power TRANSFORMER- 2 No’s.
Testing and Commissioning of 220Kv Current Transformer – 12 No’s.
Testing and Commissioning of 220Kv Circuit Breaker– 4 Set.
Testing and Commissioning of 220Kv Disconnector – 8 Set.
Testing and Commissioning of 220Kv Lightning Arrester – 12 No’s.
Testing and Commissioning of 220Kv Bus Pole Insulator – 16 No’s.
Commissioning of 220Kv Differential & Stability Checked.
Commissioning of 220Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
132KV Switchyard, Singida.
Testing and Commissioning of 132Kv Lightning Arrester – 6 No’s.
Testing and Commissioning of 132Kv Neutral Reactor – 6 No’s.
33KV Switchgear, Singida.
Testing and Commissioning of 33Kv Vacuum Circuit Breaker– 16 No’s.
Testing and Commissioning of 33Kv Current Transformer – 48 No’s.
Testing and Commissioning of 33Kv Lightning Arrester – 84 No’s.
Testing and Commissioning of 33Kv Potential Transformer – 12 No’s.
Testing and Commissioning of 33Kv 3Pole Earthing Switch – 14 No’s.
Testing and Commissioning of 33Kv Bus Pole Insulator – 12 No’s.
Testing and Commissioning of 33/0.4Kv Oil Cooled dry Type Transformer – 2 No’s.
Commissioning of 33Kv Differential & Stability Checked.
Commissioning of 33Kv ACDB & DCDB Scheme, Control and Operation checked.
400KV/220KV/132KV/33KV Switchyard, Dodoma, TANZANIA, AFRICA.
400KV Switchyard, Dodoma.
Testing and Commissioning of 400/220/33 kV 250/250/85 MVA Auto TRANSFORMER- 2 No’s.
Testing and Commissioning of 3Ø, 400/220/33 kV 250/250/85 MVA Shunt Reactor – 4 No’s.
Testing and Commissioning of 400Kv Current Transformer – 21 No’s.
Testing and Commissioning of 400Kv Capacitor Voltage Transformer – 18 No’s.
Testing and Commissioning of 400Kv Circuit Breaker– 11 Set.
Testing and Commissioning of 400Kv Disconnector – 26 Set.
Testing and Commissioning of 400Kv Lightning Arrester – 30 No’s.
Testing and Commissioning of 400Kv Bus Pole Insulator – 104 No’s.
Commissioning of 400Kv Differential & Stability Checked.
Commissioning of 400Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
220KV Switchyard, Dodoma.
Testing and Commissioning of 220/33 kV 125/125/41.6 MVA Power TRANSFORMER- 2 No’s.
Testing and Commissioning of 220Kv Current Transformer – 12 No’s.
Testing and Commissioning of 220Kv Circuit Breaker– 4 Set.
Testing and Commissioning of 220Kv Disconnector – 8 Set.
Testing and Commissioning of 220Kv Lightning Arrester – 12 No’s.
Testing and Commissioning of 220Kv Bus Pole Insulator – 14 No’s.
Commissioning of 220Kv Differential & Stability Checked.
Commissioning of 220Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
132KV Switchyard, Dodoma.
Testing and Commissioning of 132Kv Current Transformer – 4 No’s.
Testing and Commissioning of 132Kv Lightning Arrester – 4 No’s.
Testing and Commissioning of 132Kv Neutral Reactor – 4 No’s.
33KV Switchgear, Dodoma.
Testing and Commissioning of 33Kv Vacuum Circuit Breaker– 16 No’s.
Testing and Commissioning of 33Kv Current Transformer – 42 No’s.
Testing and Commissioning of 33Kv Lightning Arrester – 84 No’s.
Testing and Commissioning of 33Kv Potential Transformer – 12 No’s.
Testing and Commissioning of 33Kv 3Pole Earthing Switch – 14 No’s.
Testing and Commissioning of 33Kv Bus Pole Insulator – 12 No’s.
Testing and Commissioning of 33/0.4Kv Oil Cooled dry Type Transformer – 2 No’s.
Commissioning of 33Kv Differential & Stability Checked.
Commissioning of 33Kv ACDB & DCDB Scheme, Control and Operation checked.
400/132/33kV Mawana Substation, BOTSWANA, AFRICA.
400KV Switchyard, Mawana.
Testing and Commissioning of 400/220 kV 125 MVA Auto TRANSFORMER- 2 No’s.
Testing and Commissioning of 3Ø, 400kv 60 MVAr Reactor – 2 No’s.
Testing and Commissioning of 400Kv Current Transformer – 21 No’s.
Testing and Commissioning of 400Kv Capacitor Voltage Transformer – 12 No’s.
Testing and Commissioning of 400Kv Circuit Breaker– 7 Set.
Testing and Commissioning of 400Kv Isolator with Earth switch – 10 set.
Testing and Commissioning of 400Kv Isolator without Earth switch – 5 set.S
Testing and Commissioning of 400Kv Earth switch – 4 set.
Testing and Commissioning of 400Kv Neutral Grounding Reactor – 1 No’s.
Testing and Commissioning of 400Kv Pantograph Isolator – 1 Set.
Testing and Commissioning of 400Kv Lightning Arrester – 15 No’s.
Commissioning of 400Kv Differential & Stability of Transformer and Switchyard Checked.
Commissioning of 400Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
220KV Switchyard, Mawana.
Testing and Commissioning of 400/132 kV 80 MVA Auto TRANSFORMER- 2 No’s.
Testing and Commissioning of 220Kv Current Transformer – 21 No’s.
Testing and Commissioning of 220Kv Capacitor Voltage Transformer – 18 No’s.
Testing and Commissioning of 220Kv Circuit Breaker– 7 Set.
Testing and Commissioning of 220Kv Isolator with Earth switch – 10 set.
Testing and Commissioning of 220Kv Isolator without Earth switch – 6 set.
Testing and Commissioning of 220Kv Earth switch – 4 set.
Testing and Commissioning of 220Kv Pantograph Isolator – 1 Set.
Testing and Commissioning of 220Kv Lightning Arrester – 15 No’s.
Commissioning of 220Kv Differential & Stability of Transformer and Switchyard Checked.
Commissioning of 220Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
132KV Switchyard, Mawana.
Testing and Commissioning of 132Kv Current Transformer – 21 No’s.
Testing and Commissioning of 132Kv Capacitor Voltage Transformer – 24 No’s.
Testing and Commissioning of 132Kv Circuit Breaker– 7 Set.
Testing and Commissioning of 132Kv Isolator with Earth switch – 12 set.
Testing and Commissioning of 132Kv Isolator without Earth switch – 8 set.
Testing and Commissioning of 132Kv Earth switch – 2 set.
Testing and Commissioning of 132Kv Pantograph Isolator – 3 Set.
Testing and Commissioning of 132Kv Lightning Arrester – 15 No’s.
Testing and Commissioning of 132Kv Line Trap – 3 No’s.
Commissioning of 132Kv Differential & Stability of Transformer and Switchyard Checked.
Commissioning of 132Kv C&R Panel, ACDB & DCDB Scheme, Control and Operation checked.
33/11 KV Switchgear, Mawana.
Testing and Commissioning of 33Kv Circuit Breaker– 2 No’s.
Testing and Commissioning of 33Kv Isolator with Earth switch – 2 set.
Testing and Commissioning of 33Kv Neutral Earthing Compensator – 2 No’s.
Testing and Commissioning of 33Kv Lightning Arrester – 18 No’s.
Testing and Commissioning of 33Kv Voltage Transformer – 21 No’s.
Testing and Commissioning of 3Ø, 33kv, 25 MVAr Reactor – 2 No’s.
Testing and Commissioning of 11Kv Neutral Earthing Compensator – 2 No’s.
Commissioning of 33Kv Differential & Stability Checked.

110V Battery Bank, Mawana.


Charging and Discharging test for 110V Battery Bank.
Charging and Load test, Alarm, Indication and Scheme Checked for 110V Battery Bank.
400/132/33KV SUB - STATION OF PHOMBEYA & NKHOMA IN MALAWI, AFRICA.

 Testing & Commissioning of 400KV Circuit Breaker - 6 Sets.


 Testing & Commissioning of 400KV Pantograph Isolators with Earth Switch - 6 Sets.
 Testing & Commissioning of 400KV HCB Isolators - 10 Sets.
 Testing & Commissioning of 400KV Current Transformer - 6 Sets.
 Testing & commissioning of 400KV capacitive voltage transformer - 4 Sets.
 Testing & Commissioning of 400KV Lightning Arrester - 6 Sets.
 Testing & Commissioning of 400KV BUS Reactor (50 MVAR) - 2 Nos.
 Testing & Commissioning of 400/132/33KV 66.67 MVA ICT Single Phase Transformer - 8 No's.
 Testing & Commissioning of 400KV Switchyard.
 Testing & Commissioning of 400KV CRP Panel - 8 No’s.
 Stability Test of 400KV BUS Reactor (50 MVAR) - 2 No’s.
 Stability Test of 400/132/33KV ICT Single Phase Transformer - 8 No’s.
 Stability Test of 400KV Switchyard.
 Testing & Commissioning of 132KV Circuit Breaker - 15 Sets.
 Testing & Commissioning of 132KV HCB Isolators - 43 Sets.
 Testing & Commissioning of 132KV Current Transformer - 15 Sets.
 Testing & Commissioning of 132KV Capacitive voltage transformer - 15 Sets.
 Testing & Commissioning of 132KV Lightning Arrester - 13 Sets.
 Testing & Commissioning of 132KV Switchyard.
 Testing & Commissioning of 132KV CRP Panel - 17 Bays.
 Stability Test of 132KV Switchyard.
 Testing & Commissioning of 33KV Circuit Breaker - 2 Sets.
 Testing & Commissioning of 33KV HCB Isolators - 2 Sets.
 Testing & Commissioning of 33KV Current Transformer - 2 Sets.
 Testing & Commissioning of 33KV Switchyard Stability Test of 33KV Swich Yard
 Testing & Commissioning of 33KV/415V Station transformer Rating 1600KVA Dyn-11 - 4 No's.
 Testing & Commissioning of 33KV CRP Panel - 2 No's.
 Testing & Commissioning of 415V DIESEL GENERATOR - 2 No's.
 Testing & Commissioning of 33KV Switch Gear Board Current Transformer - 16 Sets.
 Testing & Commissioning of 33KV Switch Gear Board Potential Transformer - 4 Sets.
 Testing & Commissioning of 33KV Switch Gear Board Circuit Breaker - 10 Sets.
 Testing & Commissioning of 110V DC Battery Bank - 4 Banks
 Testing & Commissioning of 110V DC Battery Charger - 4 No's.
66/33/11KV SUB-STATION OF BLANTYRE, MALDECO LIWONDE, ZOMBA, THYOLO A,
THYOLO B, LIMBE B, NTONDA, DAVID WHITE (UGC - 2) MALAWI, AFRICA.

 Testing & Commissioning of 66KV Circuit Breaker - 01 No.


 Testing & Commissioning of 66KV Isolators - 01 No.
 Testing & Commissioning of 66KV CRP Panel - 1 No.
 Testing & Commissioning of 33KV Circuit Breaker - 23 Sets.
 Testing & Commissioning of 33KV Current Transformer - 22 Sets.
 Testing & Commissioning of 33K Isolators without Earth Switch - 36 Sets.
 Testing & Commissioning of 33KV Potential Transformer - 11 Sets.
 Testing & Commissioning of 33KV Lightning Arrestor - 15 Sets.
 Testing & Commissioning of 33KV Insulator - 24 Sets.
 Testing & Commissioning of 33KV/415V Auxiliary Transformer - 8 No's.
 Testing & Commissioning of 33KV CRP Panel - 22 No’s.
 Stability Test of 33KV Transformer - 9 No's.
 Stability Test of 33KV Switchyard
 Testing & Commissioning of 11KV Switch Gear Circuit Breaker - 28 No's.
 Testing & Commissioning of 11KV Switch Gear Current Transformer - 28 Sets.
 Testing & Commissioning of 11KV Switch Gear Potential Transformer - 6 Sets.
 Testing & Commissioning of 11KV Switch Gear Panel - 28 No's.
 Testing & Commissioning of 11KV/415V Auxiliary Transformer - 1 No.
 Testing & Commissioning of 11 KV Bus Bar - 5 No's.
 Testing & Commissioning of 11 KV Cable - 29 Sets.
400/230/15Kv SUB STATION- DEBREZEIT III ETHIOPIA EAST AFRICA
 Testing & Commissioning of 400kV GE Alstom make CB – 7 Set’s.
 Testing & Commissioning of 400kV GE T&D make CT – 7 Set’s.
 Testing & Commissioning of 400kV GE T&D make CVT – 6 Set’s.
 Testing & Commissioning of 400kV Lighting Arrestor – 7 Set’s.
 Testing & Commissioning of 400kV GE T&D Pantograph Type Disconnector - 17 Set’s.
 Testing & Commissioning of 400kV Earth Switch – 3 Set’s.
 Testing & Commissioning of 250MVA 400/230KV Transformer – 2 No’s.
 Testing & Commissioning of 400kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Testing & Commissioning of 230kV GE Alstom make CB – 7 Set’s.
 Testing & Commissioning of 230kV GE T&D make CT – 7 Set’s.
 Testing & Commissioning of 230kV GE T&D make CVT – 6 Set’s.
 Testing & Commissioning of 230kV Lighting Arrestor – 7 Set’s.
 Testing & Commissioning of 230kV GE T&D Pantograph Type Disconnector - 17 Set’s.
 Testing & Commissioning of 230kV Earth Switch – 3 Set’s.
 Testing & Commissioning of 50MVA 230/15KV Transformer – 2 No’s.
 Testing & Commissioning of 230kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Transformer & Bus Bar Stability done. 
 230kV Two Main Bus with Bus coupler Scheme Interlock Checked(On Load).
 Testing & Commissioning of 15kV Switchgear panel PT,CT,CB,Disconnector, E/S, LA - 20 No’s.
 15kV Two Main Bus with Bus coupler Scheme Interlock Checked.

230/15Kv SUB STATION– DUKEM II ETHIOPIA EAST AFRICA

 Testing & Commissioning of 230kV GE Alstom make CB – 5 Set’s.


 Testing & Commissioning of 230kV GE T&D make CT – 5 Set’s.
 Testing & Commissioning of 230kV GE T&D make CVT – 4 Set’s.
 Testing & Commissioning of 230kV Lighting Arrestor – 4 Set’s.
 Testing & Commissioning of 230kV GE T&D Pantograph Type Disconnector - 12 Set’s.
 Testing & Commissioning of 230kV Earth Switch – 4 Set’s.
 Testing & Commissioning of 50MVA 230/15KV Transformer – 2 No’s.
 Testing & Commissioning of 230kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Transformer & Bus Bar Stability done. 
 230kV Two Main Bus with Bus coupler Scheme Interlock Checked(On Load).
 Testing & Commissioning of 15kV Switchgear panel PT, CT,CB,Disconnector, E/S, LA - 16 No’s.
 15kV Two Main Bus with Bus coupler Scheme Interlock Checked.

230/15Kv SUB STATION– MODJO II ETHIOPIA EAST AFRICA


 Testing & Commissioning of 230kV GE Alstom make CB – 4 Set’s.
 Testing & Commissioning of 230kV GE T&D make CT – 4 Set’s.
 Testing & Commissioning of 230kV GE T&D make CVT – 3 Set’s.
 Testing & Commissioning of 230kV Lighting Arrestor – 3 Set’s.
 Testing & Commissioning of 230kV GE T&D Pantograph Type Disconnector - 9 Set’s.
 Testing & Commissioning of 230kV Earth Switch – 3 Set’s.
 Testing & Commissioning of 50MVA 230/15KV Transformer – 2 No’s.
 Testing & Commissioning of 230kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Transformer & Bus Bar Stability done. 
 230kV Two Main Bus with Bus coupler Scheme Interlock Checked(On Load).
 Testing & Commissioning of 15kV Switchgear panel PT,CT,CB,Disconnector, E/S, LA - 16 No’s.
 15kV Two Main Bus with Bus coupler Scheme Interlock Checked.
30MW MCM CAPTIVE POWER PLANT, AMMAN, JORDAN

 Testing and Commissioning of 32MW Generator.


 Testing and Commissioning of 11kV Switchgear Make ABB with 18 Verticals.
 Testing and Commissioning of 415V Switchgear Make ABB - 10Nos.
 Testing and Commissioning of 415V VFD Panel Make ABB – 8Nos.
 Testing and Commissioning of 2 MVA Diesel Generator Make Powerica – 2Nos.
 Testing and Commissioning of Generator Transformer (40MVA) – 1No.
 Testing and Commissioning of Auxiliary Transformer (2MVA) – 6Nos.
 Co-ordination with Client and Customer to Modify Schematic in HT panel, LT panels and VFD Panel.
 Co-ordination with Client and Customer to Upgrade Schematic and Modify Interlocks between
Captive power plant, Cement Plant and NEPCO.

TESTING AND COMMISSIONING OF FOLLOWING RELAYS:


8MW TOKYO CAPTIVE POWER PLANT, TRINCOMALEE, SRILANKA.

 Testing of Generator Neutral side CT-3 Nos.


 Testing of NGR CT and Sensitive earth fault function is checked.
 Testing of 8MW Alternator.
 Stability test done for 8MW Alternator.
 Testing of LASCPT and its secondary voltage is measure in corresponding relays.
 AVR Panel Lamp Load test was done.
 Dummy Sync was checked in CB-2 Tie Feeder, CB-3 TIE feeder & CB-6 Grid Incomer feeder
Commissioning of Generator Transformer.
 Con guration, Testing and Commissioning of 10MVA Power Transformer.
 Co-ordination and Commissioning of 11kV Switchgear panel.
 Co-ordination and Commissioning of 2MVA Transformer.
 Observation of all commissioned equipment and ensured the proper operation.

NUMERICAL RELAY RELATED WORKS

 Con guration, Testing and Commissioning of 33kV ABB Numerical Relays- 5 Nos.
 Con guration, Testing and Commissioning of Spare ABB Numerical Relays-3 Nos.
 Con guration, Testing and Commissioning of 11kV ABB Numerical Relays-2 Nos.
 Testing and Commissioning of Electromechanical relays at415V PCC Panel-4 Nos.
 Con guration, Testing and Commissioning of Siemens 7UM622.
 Con guration, Testing and Commissioning of Multifunction meter- 4 Nos.
 Con guration, Testing and Commissioning of Trivector Meter- 3 Nos.
 Con guration, Testing and Commissioning of Synchronizing Relay Alstom (SKE).
4MW KMRI CAPTIVE POWER PLANT, MIRIGAMA, SRILANKA.

Normal Testing Activities


 Testing and Commissioning of 4MW Alternator.
 Testing and Commissioning of LAPT-3 nos.
 Testing and Commissioning of HT Cables from Alternator to Transformer.
 Testing and Commissioning of SEF CT.
 Testing and Commissioning of 11/0.415kV Generator Transformer.
 Alternator Stability was done.
 Synchronizing Check done by back Charging.

Relay Testing Activities


 Con guration, Testing and Commissioning of Siemens 7UM622.
 Con guration, Testing and Commissioning of Sync Check Relay SKE11.
 Con guration, Testing and Commissioning of CDG11 Standby Ef relay 1 No.
 Con guration, Testing and Commissioning of VAJ Relays 3 Nos.
 Con guration, Testing and Commissioning of Energy meter, trivector meter, Ammeters, Power
factor meters, Frequency meters.
 Observation of all commissioned equipment and ensured the proper operation.

6 MW CAPTIVE POWER PLANT, MAHIYANGANA, SRILANKA DENDRO BIOMASS - SRILANKA

 Testing and Commissioning of Surge Arrestor, Counter and Potential.


 Testing and Commissioning of Generator Line side CT and Neutral Side CT.
 Testing and Commissioning of 6MW Alternator.
 Testing and Commissioning of Exciter and Excitation Transformer.
 Alternator Stability was checked.
 System back charging and dummy sync was done.
 Short Circuit Test Open Circuit test was done.
 Generator breaker Synchronization with 33 kV Grid Breaker was done.
 Observation of all commissioned equipment and ensured the proper operation.
4.70 MW SAM REE DYING GROSS POWER PLANT
GHORASHAL, NARSINDI(DT), BANGLADESH

 Testing & Commissioning of 11KV Circuit Breaker - 4 No's.


 Testing & Commissioning of 11KV Current Transformer - 13 No's.
 Testing & Commissioning of 11KV Potential Transformer - 3 No's.
 Testing & Commissioning of LT PCC Panel Current Transformer - 9 No 's.
 Testing & Commissioning of LT PCC Panel Potential Transformer - 3 No 's.
 Testing & Commissioning of LT PCC Panel Control Transformer - 1 No.
 Testing & Commissioning of WT MCC Panel Current Transformer - 1 No’s.
 Testing & Commissioning of WT MCC Panel Control Transformer - 2 No's.
 Testing & Commissioning of Boiler MCC Panel Current Transformer - 1 No.
 Testing & Commissioning of Boiler MCC Panel Control Transformer - 2 No's.
 Testing & Commissioning of PDB Panel Current Transformer - 1 No.
 Testing & Commissioning of PDB Panel Control Transformer - 2 No's.
 Testing & Commissioning of TG & Auxiliary MCC Panel Current Transformer - 1 No.
 Testing & Commissioning of TG & Auxiliary MCC Panel Control Transformer - 2 No's.
 Testing & Commissioning of MLDB Panel Current Transformer - 1 No.
 Testing & Commissioning of MLDB Panel Control Transformer - 2 No's.
 Testing & Commissioning of Alternator Panel - 1 No.
 Testing & Commissioning of NGR Panel - 1 No.
 Testing & Commissioning of Auxiliary Transformer - 1 No.
 Testing & Commissioning of Lightning Transformer - 1 No.
 Testing & Commissioning of Standby Transformer - 1 No.
 Testing & Commissioning of Generator Panel - 1 No.
 Testing & Commissioning of AVR Panel - 1 No.
 Testing & Commissioning of Meter CUM Synchronizing Panel - 1 No.
 Testing & Commissioning of REF 615 ABB Feeder Protection Relay - 5 No's.
 Testing & Commissioning of REG 670 ABB Generator Protection Relay - 1 No.
220/20Kv SUB STATION – DOSHI, AFGHANISTAN

 Testing & Commissioning of 220kV CB – 5 Set’s.


 Testing & Commissioning of 220kV CT – 7 Set’s.
 Testing & Commissioning of 220kV CVT – 3 Set’s.
 Testing & Commissioning of 220kV PT – 3 Set’s.
 Testing & Commissioning of 220kV Lighting Arrestor – 2 Set’s.
 Testing & Commissioning of 220kV Disconnector - 5 Set’s.
 Testing & Commissioning of 220kV Earth Switch – 5 Set’s.
 Testing & Commissioning of 16MVA 220/20KV Transformer – 1 No.
 Testing & Commissioning of 100k VA 20/0.415V Transformer – 1 No.
 Testing & Commissioning of 220 kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Testing & Commissioning of 20kV Switchgear Panels PT,CT, CB, Disconnector, E/S, LA.
 Transformer stability & Bus Bar Stability checked.
 SCADA, Telecommunication and trip signal checked.

220/20Kv SUB STATION– CHARIKAR, AFGHANISTAN

 Testing & Commissioning of 220kV CB – 4 Set’s.


 Testing & Commissioning of 220kV CT – 5 Set’s.
 Testing & Commissioning of 220kV CVT – 3 Set’s.
 Testing & Commissioning of 220kV PT – 2 Set’s.
 Testing & Commissioning of 220kV Lighting Arrestor – 2 Set’s.
 Testing & Commissioning of 220kV Disconnector - 4 Set’s.
 Testing & Commissioning of 220kV Earth Switch – 4 Set’s.
 Testing & Commissioning of 16MVA 220/20KV Transformer – 1 No.
 Testing & Commissioning of 100k VA 20/0.415V Transformer – 1 No.
 Testing & Commissioning of 220 kV CRP Panels.
 Power Transformer Body Protection Wiring & Functional Operations Checked.
 RTCC & OLTC Wiring & Functional operation Checked.
 Testing & Commissioning of 20kV Switchgear Panels PT,CT,CB, Disconnector, E/S, LA .
 Transformer stability & Bus Bar Stability checked.
 SCADA, Telecommunication and trip signal checked.
14.9MW SUGAR PLANT & 33/11KV SUBSTATION, KALIRO, UGANDA SUGAR AND ALLIED
INDUSTRIES LTD - UGANDA - EAST AFRICA

 T&C Of 33KV Switchyard.


 T&C Of 11KV HT Panel Switchgear.
 T&C Of 11KV CBCT & Auxiliary relay.
 T&C Of 33/11KV Relay panel Auxiliary Relay & Alternator Auxiliary Relay Testing done for
GRP,MCSP,TRP Panels.
 T&C Of 10MVA Power Transformer.
 T&C Of Auxiliary Transformer CO –Generation(2.5MVA).
 T&C Of Mill Trafo-1 (1.25MVA) Mill Trafo-2 (1.25 MVA).
 T&C Of Boiling House Transformer-1 (1.6MVA).
 T&C Of 2.5 MVA DT Incomer, 1 MVA TG Incomer & 1 MVA DT Incomer CT.
 Differential and REF Stability tested for 10 MVA Power Transformer.
 11 KV HIGH VOLTAGE test Completed for 11 KV Switch Gear BUS,O/G & I/C Cables.
 HIGH VOLTAGE test Completed for 33KV & 11KV Power Transformer Cables, 14.9 MW 11KV
Generator Cable& 11KV LAVT Panel Cables, NGR Cables.
 Alternator PI Value Measured & Alternator Differential Stability Tested.
 Con guration, Testing and Commissioning of Generator Protection Relay .
Areva-P341,Line Protection.
Relay Areva-P442, Areva-P632, Directional/Non Directional Relay Areva-P127.
32MW CAPTIVE POWER PLANT

ADDAX BIO ENERGY- SIERRA LEONE - WEST AFRICA


 Testing and Commissioning of 32MW Alternator.
 Testing and Commissioning of Neutral Side CT and Phase Side CT.
 Testing and Commissioning of LAPT.
 Testing and Commissioning of Exciter and Excitation Transformer.
 Testing and Commissioning of Bus Duct.
 Stability test was done for Alternator.
 Modi cation was done in BFP Motor Panel.
 Modi cation was done in RDOL Starter.
 Co-ordination with Client and Customer to Modify Schematic in HT panel, LT panels and VFD.
 Commissioning of TG & TG CB @ Dead bus mode.
 LT Breakers commissioning Assistance.
PT. TEREOS 1X9MW CO-GENERATION POWER PLANT, CILEGON, INDONESIA.

 Testing and Commissioning of HT Panel testing – 6 Vertical.


 Testing and Commissioning of Generator Testing – 1 quantity.
 Testing and Commissioning of Generator Transformer – 1 quantity.
 Testing and Commissioning of Auxiliary Transformer - 2 quantity.
 Testing and Commissioning of Generator Stability Test.
 Testing and Commissioning of Dummy Synchronization Test for TG Breaker and
other Grid Breakres.
 Testing and Commissioning of LASCPT (CT, PT, LA, SC)
o CT – 6 Nos& Generator Neutral side CT – 3 Nos.
o PT – 6 Nos.
o LA & SC.
o Exicitation T/G – 1 No.
 Testing and Commissioning of NGT or NGR for Generator
o CT – 1 No.
o Earthing or Grounding T/f – 1 No.
o Resistor Bank – 1 No.
 Testing and Commissioning of Earthing Transformer
o CT – 2 Nos.
o Resistor Bank.

 Testing and Commissioning of Existing Plant HT Panel Testing


o CT – 3 Nos.
o PT – 3 Nos.

 Battery Discharge Test for 110V-DC & 220V DC.


 Inter Panel Wiring Checked for AVR, SYN, RMP.
 RTCC Panel Wiring through and Charging.

LAOS PROJECTS

1.5 MW SULPHUR TREATMENT PLANTLAO MEE SAI - LAOS, Thailand

 Complete Dismantling, Overhauling and Reassembling of 1.5 MW Merlin Make Generator.


 Checking all Power cables and Control Cables.
 Calibrating of All relays in TGP, AVR, MCC and Outgoing Feeders.
 SCADA and PLC Modules checking and veri ed according to the Schematics and Logics.
 Checking all the Interlocks in Thermal Power Plant.
 Checking Batteries and Battery charger, measured voltage of all batteries.
 Checking the DC startup Panel.
 Recommend some changes in Relay settings and Meters to be replaced.
TESTING & COMMISSIONING OF PROTECTION RELAYS DURING ANNUAL SHUTDOWN
MAINTENANCE IN LIBIYA
12 MVA, 66/20 KV POWER TRANSFORMER, DJIBOUTI, EAST AFRICA

 Testing and Commissioning of 63/20 kV 10/12 MVA TRANSFORMER AMF-001 ABB – 1 No.

 Testing and Commissioning of 63/20 kV 10/12 MVA TRANSFORMER AMF-002 ABB – 1 No.

 Testing and Commissioning of 1.5 MVA TRAFO SCHNEIDER ELECTRIC – 7 Nos.

 Testing and Commissioning of 100 KVA transformer – 1 No.

 Testing and Commissioning of 22/11Kv Transformer – 1 No.

 Testing and Commissioning of 11/0.415 Kv Transformer – 9 Nos.

 Testing and Commissioning of Protection Relay – 19 Nos.


Installation of 400 kV Lemugur Substation in TANZANIA, AFRICA.

Installation of 400 kV Circuit Breaker-10 set


Installation of 400 kV Circuit Breaker for Shunt Reactor- 4 set
Installation of 400 kV Current Transformer- 42 No’s
Installation of 400 kV Current Transformer for Shunt Reactor-12 No’s
Installation of 400 kV Capacitive Voltage Transformer- 18 No’s
Installation of 400 kV Lightning Arrestors- 30 No’s
Installation of 400 kV Isolator with Earth Switch- 6 No’s
Installation of 400 kV Isolator without Earth Switch- 24 No’s
Installation of 400 kV Busbar od Aluminum Alloy Tube – 1 Lot
Installation of 400 kV set of Bus supports, couplers, conductors, clamps, etc.,- 1 Lot
Installation of 400 kV Conductors for strain Bus flexible connection to switchgear- 1 Lot
Installation of 400 kV Post Insulator for busbar arrangements- 1 Lot
Installation of Complete bay set of 400 kV Suspension and/ or Strain Insulator Strings- 1 Lot
Installation of Complete bay set of 400 kV Conductors, clamps, Connectors, etc.,- 1 Lot
Installation of 400 kV Terminal Cabinets with auxiliary device- 1 Lot
Installation of Control and signaling panel for Incoming and outgoing 400 kV Line-shunt reactor bays- 1 Lot
Installation of Control and signaling panel for 400 kV Transformer bays- 1 Lot
Installation of Protection Panel for Incoming and outgoing 400 kV Line bays- 1 Lot
Installation of Protection panel for 400 kV Shunt Reactor- 1 Lot
Installation of Protection Panel for 400 kV Main Bus bay- 1 Lot
Installation of Protection of 400 kV Transformer bays- 1 Lot
Installation of Communication System- 1 Lot
Installation of Digital Control and monitoring System- 1 Lot
Installation of AC Auxiliary Services- 1 Lot
Installation of DC Auxiliary Services- 1 Lot
Installation of Substation Grounding- 1 Lot
Installation of 220 kV Lemugur Substation in TANZANIA, AFRICA.

Installation of 220 kV Lightning Arrestors- 33 No’s


Installation of 220 kV Capacitive Voltage Transformer - 18 No’s
Installation of 220 kV Bus bar Isolator without earth switch - 21 No’s
Installation of 220 kV Line Isolator with earth switch – 4 No’s
Installation of 220 kV Bypass Isolator without earth switch – 4 No’s
Installation of 220 kV Current Transformer- 33 No’s
Installation of 220 kV Circuit Breaker-12 set
Installation of 220 kV set of bus supports, couplers, conductors, clamps, connections-1 Lot
Installation of 220KV conductors for strain bus flexible connection to switch gear – 1 Lot
Installation of 220 kV Complete bay support insulator strings and /or post insulators- 1Lot
Installation of 220 kV Complete bay suspension and/or strain insulator strings- 1 Lot
Installation of 220 kV complete Line-Trap – 1 set
Installation of 33 KV Lightning Arrestors- 30 No’s
Installation of 33KV XLPE cable from 220/33kv transformer to 33KV incomer -1 Lot
Installation of 220KV Network interconnection-Additional works for BABATI 220KV substation control and
protection panel – 1 Lot
Installation of 220KV Network interconnection-Additional works for existing Arusha (NJIRO) 220KV
substation control and protection panel – 1 Lot
Installation of 220 KV cabinets complete with auxiliary devices and terminals block – 1 Lot
Installation of 220 KV control and signaling panel for transformer bays – 1 Lot
Installation of 220 KV control and signaling panel for bus coupler bays – 1 Lot
Installation of 220 KV protection panel for incoming and outgoing – 1 Lot
Installation of 220 KV protection panel for shunt reactor bays – 1 Lot
Installation of 220 KV protection panel for main bus and bus coupler bays – 1 Lot
Installation of 220/33 KV protection panel for transformer bays – 1 Lot
Installation of 220/33 KV protection panel for power transformer bays – 1 Lot
Installation of 220 KV control and signaling for power transformer bays – 1 Lot
Installation of 220 KV communication system IP phones – 2 No’s
Installation of 220 KV communication system Telephone and coaxial cable – 1 Lot
Installation of 220 KV communication system travelling wave fault location system – 1 Lot
Installation of 220 KV substation grounding – 1 Lot
Installation of 220 KV shield wire system – 1 Lot
Installation of 220 KV miscellaneous lighting and low voltage power supply – 1 Lot
Installation of 220 KV miscellaneous LV, AC, DC multicore and auxiliary cables – 1 Lot
Installation of 220 KV miscellaneous embedded parts – 1 Lot
Installation of 220 KV miscellaneous Boxes for pad locks and keys – 1 Lot
Domestic (PAN INDIA) AIS/SWITCHYARD SUBSTATION PROJECTS
Sl.No. Description Client Location
1 1200Kv Switchyard - Bina L&T Madhya Pradesh
2 765 Kv Switchyard - Bhanaskantha PGCIL Gujarat
3 765 Kv Switchyard - Chittorgarh PGCIL Rajasthan
4 765/400 KV Substation - Khetri PGCIL Rajasthan
5 765/400 KV Substation - Jatikara PGCIL New Delhi
6 765/400 KV Substation - Sikar PGCIL Rajasthan
7 765/400 KV Substation - Bhadla PGCIL Rajasthan
8 765/400 Kv Substation - Bhiwani PGCIL Haryana
9 765/400 KV Substation - Jaisalamar PGCIL Rajasthan
10 400/220 Kv Substation - Unchahar NTPC Uttar Pradesh
11 400/220 Kv Substation - NP Kunta TPTCL Andra Pradesh
12 400/230/110 Kv Substation - Dharmapuri TNEB Tamilnadu
13 400 Kv Substation - Boisar PGCIL Mumbai
14 400 Kv Substation - Khandawa PGCIL Madhya Pradesh
15 400 Kv Substation - Shujalpur PGCIL Madhya Pradesh
16 400 Kv Substation - Dehgam PGCIL Gujarat
17 400 Kv Substation - Indore PGCIL Madhya Pradesh
18 400 Kv Substation - Bhadravati PGCIL Mumbai
19 400/220 Kv Substation - Bhadla PGCIL Rajasthan
20 400/230/33 Kv Substation - Kayathar TNEB Tamilnadu
21 400 Kv Switchyard of Indira Sagar Power Station NHDC Madhya Pradesh
22 400/220 Kv Switchyard - Kalpaka APPTCL Andra Pradesh
23 400/220 Kv Substation - Hassan KPTCL Karnataka
24 400/220 Kv TTS Substation - Kayathar TNEB Tamilnadu
25 400 Kv Switchyard - Samba PGCIL Jammu
26 400 Kv Switchyard - Chandrapur MPPTCL Maharsatra
27 400 KV Substation - Moga PGCIL Punjab
28 400 KV Substation - Kayathar TNEB Tamilnadu
29 400 KV Substation - Amritsar PGCIL Punjab
30 400/220KV Substation - Jajpur OPTCL Orissa
31 400/220KV Substation - Abdullapur PGCIL Haryana
32 400/220 KV Substation - Fatehabad PGCIL Haryana
33 400/220 KV Substation - Kishenpur PGCIL Jammu
34 400 KV Substation - Kamuthi TNEB Tamilnadu
35 ±800 Kv HVDC Transmission Line - Pugalur PGCIL Tamilnadu
36 400 KV Substation - Kamuthi TNEB Tamilnadu
37 400/220 KV Substation - Jalandar PGCIL Punjab
38 400/33 KV CPSU-1 Substation - Bap TATA POWER Rajasthan
Domestic (PAN INDIA) AIS/SWITCHYARD SUBSTATION PROJECTS
Sl.No. Description Client Location
39 400/33 KV CPSU-2 Substation - Bap TATA POWER Rajasthan
40 400/220/132 Kv Substation - Gaya PGMTL Bihar
41 400/220/132 Kv Substation - Saharsa PGCIL Patna
42 400/220/33 Kv Substaion - Guna MPPGCIL Madhya Pradesh
43 230 Kv Purasai Substation - vandavasi TNEB Tamilnadu
44 230 Kv Substation Extention Project TNEB Tamilnadu
45 230/33 Kv Substation - Sankaraperi TNEB Tamilnadu
46 220/33 Kv Substation - Ottanatham TNEB Tamilnadu
47 230 Kv Extention Project Substation - Perundurai TNEB Tamilnadu
48 230 Kv Substation - Musiri TNEB Tamilnadu
49 230/110 Kv Substation - CMBT TNEB Tamilnadu
50 220/33 Kv Substation - Alangulam TNEB Tamilnadu
51 230/33 Kv Substation - Vellapanery TNEB Tamilnadu
52 110/33 Kv Substation - Karur TNEB Tamilnadu
53 110/33 Kv Substation - Yadgir KPTCL Karnataka
54 110/33 Kv Substation TNEB Tamilnadu
55 110/33 Kv Substation - Narikudi TNEB Tamilnadu
56 110/33 Kv Substation Substation - Gurmatkal KPTCL Karnataka
57 110/33 Kv Substation TNEB Tamilnadu
58 110/33 Kv Extention substation - Kamatchipuram TNEB Tamilnadu
59 110/11 Kv Substation - Minjur TNEB Tamilnadu
60 110 Kv Substation - Thiruvanthapuram KESTCL Kerala
61 110 Kv Substation - Samayanallur TNEB Tamilnadu
62 110/33 Kv Substation - Kaluneerkulam TNEB Tamilnadu
63 132/25KV Railway Substation - Sadalpur TSS Rajasthan
64 11/33 Kv LAVH Purush Sardar Vallabai SSK - Pandariya Sugar Mill Chattishgarh
65 66/33 Kv 30 MW Solar Power Plant - Kabbali KPTCL Karnataka
66 66/33 Kv 30 MW Solar Power Plant - Bhandahalli Hanur KPTCL Karnataka
67 33/11 Kv Substation - Ennore TNEB Tamilnadu
68 Indian Oil Corporation Limited - Trichy TNEB Tamilnadu
69 33/25KV Metro Substation - Kochi KMRL Kerala
70 33/25KV Metro Substation Package - 1 - Kolkatta WBMRL West Bengal
71 33/25KV Metro Substation Package - 2 - Kolkatta WBMRL West Bengal
72 33/11/0.41 Kv Substation - Kadappa Zuari Cement Andra Pradesh
73 11/0.41 Kv Substation - Sunguvarchathiram SAMSUNG Tamilnadu
74 11/0.41 Kv Substation - Sriperumbattur SAINT-GOBIAN Tamilnadu
75 33/11/0.41 KV Substation - Namrup APL Assam
76 11/0.41 KV Substation - Dariba Vedanta Rajasthan
Domestic (PAN INDIA) POWER PLANT PROJECTS
Sl.No. Description Client Location
1 1000 MW Solar Power Plant - Anathappur NTPC Andra Pradesh
2 2 x 350 MW Ind barath Energy Utkal Limited - Jharsuguda Hindu Bharat Odisha
3 5 MW Sugar Power Plant Uttam Industries Chattisgarh
4 3 x 8 MW Sudarshan Chemicals Ltd - Roha Thermax Limited Maharastra
5 1 x 8 MW Cogen Section - Shree Halasidhnath SSK ltd - Belgaum Halasidhnath Karnataka
6 1 MW Solar Power Plant - GMR IT GMR Andra Pradesh
7 55 MW Solar Power Plant - Kovilpatti NLC Tamilnadu
8 30 MW Narmada Sugar Power Plant - Narasinghgarh Narmada Sugars Madhya Pradesh
9 50 MW Power plant BHEL - Surat ONGC Gujarat
10 2 MW Solar Power Plant - Bijapur KPTCL Karnataka
11 15.4 MW Sugar Factory BHIMA SHANKAR Maharastra
12 30 MW Solar Power Plant - Pavagada TATA POWER Karnataka
13 2 X 300 MW Thermal Power Plant - Nawapara TRN ENERGY Chattisgarh
14 30 MW Narmada Sugar Power Plant - Narasinghgarh Narmada Sugars Madhya Pradesh
15 2 x 10 MW Solar Power Plant - Paramakudi TNEB Tamilnadu
16 5 MW Horlicks Factory - Rajamundhry GSK Consumer Health care Ltd Andra Pradesh
17 100 MW Solar power plant - Kayathar NLC Tamilnadu
18 4 MW Power Plant & 11 Kv Switchgear KPTCL Karnataka
19 5 MW Chettinad Cement factory Chettinad Cement Maharastra
20 30 MW Solar Power Plant - Bhandahali KPTCL Karnataka
21 4 MW STG Power plant - Dahej Megmani Gujarat
22 60 MW Solar Power Plant - NTPC ACME Karnataka
23 5 MW Cement Factory Anjani Portland Cements Andra Pradesh
24 15 MW Cummulative Solar Power Plant - Chintamanipatti SIEMENS GAMESA Tamilnadu
25 2 x 660 Thermal Power Plant - Jharsguda OPGCL Odisha
26 3 X 660 MW Thermal Power Plant - Ghatampur GTPPL Uttar Pradesh
27 2 x 660 MW Thermal Power Plant - Meja NTPC Uttar Pradesh
28 4MW Generator plant - Kota Atomic -Nuclear Rajasthan
29 9MW Generator Plant - Dahej Megmani Gujarat.
30 4MW Generator plant - Gummidipoondi Birla Carbon Tamilnadu
31 150MW Solar Power Plant - Kovilpatti GRT Jewllary Tamilnadu
32 75MW Solar Power Plant - Amguri ASEB Assam
33 1*13MW Ultratech Cement - Pindwara Ultra Tech Cement Uttar Pradesh
34 1*19 MW Chettinad Cement - Dachepalli Chettinad Cement Andra Pradesh
35 9MW STG & GTG - Namrup APL Assam
36 2*225MW Sarvanti Gas Power Plant - Kashipur SEPL Uttarkand
Domestic (PAN INDIA) GIS/SWITCHYARD SUBSTATION PROJECTS

Sl.No. Description Client Location


1 765/400 Kv GIS Substation - Nizambad TPTCL Hyderabad

2 400/220 KV GIS Substation - Kala PGCIL Dadra & Haveli


3 765/400 Kv GIS Substation - Maheshwaram TPTCL Hyderabad

4 400/220 Kv GIS Substation - Tuthukudi TNEB Tamilnadu


5 230 Kv GIS Substation - Irunkattukottai HYUNDAI Tamilnadu
6 230/110 Kv GIS Substation - Porur TNEB Tamilnadu
7 132 Kv GIS Substation - Jagalur KPTCL Karnataka
8 220 Kv GIS Substation - Kumbalkodu KPTCL Karnataka

9 400 Kv GIS Substation - Sagardighi WBSETCL Kolkatta


10 110 Kv GIS Substation - Thirumangalam TNEB Tamilnadu
11 400/220 Kv GIS Substation - Guindy TNEB Tamilnadu
12 400/220 KV GIS Substation - Kovilpatti PGCIL Tamilnadu
13 400 Kv GIS Substation - Badun Adani Group Uttar Pradesh

14 220/110 Kv GIS Substation - Chengalpattu MANDO Tamilnadu


15 400Kv GIS Substation - Maharanibarg PGCIL New Delhi

TESTING INSTRUMENTS

Normal Testing Instruments


 Digital Multimeter
 Digital Insulation Tester (0-5kV)
 Digital Clamp Meter
 Digital Tong Tester
 Primary Injection set
 High Voltage Tester-60/70kV-AC/DC (15 min.
withdraw)
 High Voltage Tester-30/40kV -AC/DC
 DC Source
 Earth Tester

Special Equipment’s
 CT Analyser
 LCR Meter
 CPC 100
 VLF (HVA28TD)

Transformer Testing Instrument


 Winding Resistance Measurement kit 10A
 Turns Ratio Measurement
 Tan-Delta Tester
 Sweep Frequency Response Analyzer (SFRA) Tester
 BDV Tester
 Thermography
 Partial Discharge Test

Circuit Breaker Testing Instruments


 Dynamic Contact Resistance Measurement
 Dew Point Meter
 Three Pole Timer
 Contact Resistance Measurement

Relay and Energy Testing Instruments


 3 Phase Injection kit Omicron
 3 Phase Injection kit Ponova
 Power Duality Analyzer
 Single Phase Injection kit

Installation tools Testing Instruments


 Oil Filtration Machine (6KL &10 KL)
 Oil Storage tank 10KL
 Welding Machine
 Drilling Machine
 Gas cutting Machine
 Dry Oil Generator
 IPS Tube Bending Machine
GOVERNMENT PROJECTS

NLC

MPPGCL TANZANIA

PRIVATE PROJECTS