Zhejiang GRL Electric Co.,Ltd. —— SFPV NH-00(NT00)/ CI Blade fuse Ml Blade fuse introduce ak SFPV NH-00 (NT00) /L NH fuse is suitable for DC48vV, rated current up to 160A circuit, as industrial electrical equipment in the distribution equipment for All performance comply with GB/T 13539.2/IEC 60269-2 Utilization category: gG ll Model name and meaning F-D - 00 SFPV NH -00(NTOO)/L DN e Rated Current(A) Rated Voltage (V) ternative code Designing code 1: With cover Fuetnk size 2: Without cover signing code Model cod: Blade fuse ee ‘Company code ll Shape and Size RT16(NTOO) Fuse-link 15 124 Fuse /01 ll DNF1-00/1 Single pole fuse holder (With cover) G R L Sat Ml DNF1-00/3 3P fuse holder (With cover) Hh i! il i ‘ wy 4 ! 2 00 { Ml DNF2-00 fuse holder (Without cover) Fuse /02 wwregrifuse.com GRL Rated current A “ ao | Maney [Pa] bcasv 160 | 09 100kA 92 168 125 93 75 160 12 2 Hl Normal operating conditions 1) Atmospheric conditions When the maximum temperature is 40°C, the relative humidity does not exceed 50%. When the maximum temperature is 20°C, the relative humidity does not exceed 90%. 2) Ambient temperature (Tj) Normal ambient temperature: -5 °C to 40°C Permissible ambient temperature: -40°C to 80° C Outside the normal ambient temperature range, the rated current value has to be corrected, the correction factor is Kt. The formula for selecting the rated current of the fuse is ItInx Kt. K eecesea- YVRLO=NO -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature 3) Altitude The altitude must not exceed 200m. When exceeded, the temperature rise of the fuse increases by about 0.5K for every 100 m rise. In general, the fuses used in open environment can ignore the influence of altitude on rated current and still be selected in accordance with standard conditions. For fuses used in closed environment, if the ambient air temperature of the box or the temperature inside the box does not decrease significantly with the eleva- tion and can still reach over 40°C, itis necessary to reduce the capacity of the rated current. ‘The formula for estimating the rated current of the fuse is as follows: 1=In x (1-(h-2000)/100x0.5 100) ‘Among them |-- Rated current after capacity reduction In ~ Rated current of the fuse H~ Altitude (2.000m) MH Maintenance and storage 1) Maintenance Clear dust and check contact points regularly. During maintenance check, cut off the power supply according to safety regulations. Do not remove the fuse when the power is on. 2) Storage The fuse should be stored in a warehouse with good air circulation, relative humidity (at 25°C) no more than 90%, and temperature not higher than +40°C and not less than -30°C. Fuse /03

You might also like