A GF LIGHTING LAYOUT A 2F LIGHTING LAYOUT


1 2 SCALE 1:100 M 2 2 SCALE 1:100 M

USE 5/8" GALVANIZED ANCHOR


BOLT
ATTACHMENT AND CONDUCTORS
SHALL HAVE A CLEARANCE NOT LESS
THAN 38" FROM WINDOWS, DOORS,
PORCHES , FIRESCAPES OR SIMILAR
LOCATON
POWER SERVICE DROP LINE
2 - 50 mm2 THHN COPPER WIRE
APPROVED WEATHER HEAD WITH 4 1 - 30 mm 2 TW GROUND WIRE
HOLES INSTALLED WITHIN 9" AND 18"
BELOW ATTACHMENT
SERVICE CONDUCTORS TO BE INSTALLED M
LOAD SCHEDULE
0.5 m

BY LOCAL POWER UTILITY COMPANY SERVICE ENTRANCE CAP


PANEL BOARD AT GROUND FLOOR
CONNECTIONS (SPLICING SHALL BE DONE 150 AT 2P, 125 AF
VOLT WIRE ENTRANCE CAP BY LOCAL POWER UTILITY COMPANY)
CONDUIT SIZE 230 V MAIN CB
AMP. AMPERE AT DESCRIPTION MAIN N. GND. (uPVC) SERVICE ENTRANCE
CKT DESIGNATION VOLTS QTY SET
(A) THHN THHN TW
0.8 m

CONDUCTORS (BY OWNER)


1 20A 20A 2
1 LIGHTING OUTLET 230 440 22 1.91 20 LED LIGHTS 1-3.5 1-3.5 1-2.0 1 20mmD LEAVE 18" MIN. SLACK
STRIP/CORD LIGHT, 2 CHANDELIER, LED
2 LIGHTING OUTLET 230 1025 18 4.46 20 LIGHTS 1-3.5 1-3.5 1-2.0 1 20mmD
SERVICE STANDPIPE AND 3 4
STRIP/CORD LIGHT, 2 CHANDELIER, LED 20A 20A
3 LIGHTING OUTLET 230 280 14 1.22 20 LIGHTS
1-3.5 1-3.5 1-2.0 1 20mmD WEATHER HEAD (BY OWNER)
TEL. ENT.CAP
4 LIGHTING OUTLET 230 685 15 2.98 20 LED LIGHTS 1-3.5 1-3.5 1-2.0 1 20mmD T 5 20A 20A 6
CONCRETE POST
6 CONVENIENCE OUTLET 230 1000 5 4.35 20 1-3.5 1-3.5 1-2.0 1 20mmD
1.2 m

8 CONVENIENCE OUTLET 230 1600 8 6.96 20 1-3.5 1-3.5 1-2.0 1 20mmD T 7 20A 30A 8

9 CONVENIENCE OUTLET 230 600 3 2.61 20 1-3.5 1-3.5 1-2.0 1 20mmD


4.90 m

KILOWATT-HOUR PB 9 10
10 2000 1 8.70 30 1-5.5 1-5.5 1-3.5 1
18
REFRIGERATOR
SPARE
230 20mmD
METER
M SPARE SPARE

11 12
19 SPARE T SPARE SPARE

1.7 m
20 SPARE
TOTAL LOAD OF BUILDING 7630 33.19 A
RSC TERMINAL T T
TTC PB LOAD
1.2 m

POLE TO
FINAL FLOOR LINE
T
T ELECTRIC
METER
T GROUND
E LOAD SCHEDULE T
0.3 m 0.90 m

FLOOR LEVEL
T T T T T T T T T T T T T T
4 2 SCALE NTS

300 X 900 FOOTING


W/ 6D12 MMBARS BW.

E SERVICE ENTRANCE E SINGLE LINE DIAGRAM


2 2 SCALE NTS 2 2 SCALE NTS

R.A. 9266 ARCHITECT REVISIONS ELECTRICAL ENGINEER PROJECT TITLE OWNER SHEET CONTENT SHEET NO.
ALL ARCHITECTURAL PLANS, SPECIFICATIONS
AND OTHER CONTRACT DOCUMENTS,
DRAWINGS AND SPECIFICATION, DULY GF LIGHTING LAYOUT
SIGNED, STAMPED AND SEALED AS
INSTRUMENT OF SERVICE, ARE THE
PAULINO D. DELMAS
2 STOREY RESIDENCE 2F LIGHTING LAYOUT
INTELLECTUAL PROPERTY AND DOCUMENTS ROBERT RAINIER T. ACOBA LOAD SCHEDULE

E2
OF ARCHITECT WHETHER THE OBJECT FOR
WHICH THEY ARE MADE IS EXECUTED OR NOT.
IT SHALL BE UNLAWFUL FOR ANY PERSON TO
DUPLICATE OR TO MAKE COPIES OF THE SAID
LOCATION SPS ROMUALDO AND MAYA DULCE SERVICE ENTRANCE
DOCUMENTS FOR USE IN THE REPETITION OF PRC NO.: 50327 PTR NO.: 7637045 DRAFTED BY PRC NO.: PTR NO.:
AND FOR OTHER PROJECTS OR BUILDINGS,
0001823 6233406 SINGLE LINE DIAGRAM
WHETHER EXECUTED PARTLY OR IN WHOLE,
WITHOUT THE WRITTEN WRITTEN CONSENT
OF THE ARCHITECT OR AUTHOR OF THE SAID
TIN NO.: 768-994-495 DATE: 01/24/2023 RAIN TIN NO.: DATE: JAN. 04, 2023 SAN MIGUEL, AGOO, LA UNION
DOCUMENTS. PLACE: AGOO, LA UNION PLACE: LA TRINIDAD, BENGUET

You might also like