Programming Step :
Using Two Segments and 4 Keys Enter, Back, Up and Down. User can program the parameter. Press
the Enter key for 3 Sec to enter into Program Mode. Very first it will ask for password. After entering
password correct you can access board parameter. If password enters incorrect five times system gets
block off.
All Parameter are divided in three group A,B,C.
Using UP and DN key User can change group of parameter as per your requirement.
And press enter key on your required group you will get list of parameter related that group.
E.g. suppose you want to change a FAN Off timing.
Step 1: Press Enter Key for 3 Sec you will get P on segment. After that enter a correct password. Then
go to Group A using UP/DN Key.
Step 2: Press Enter On A Group you will got list of A group parameter. Now using UP/DOWN Key go
to A0 Parameter and press enter key you will get value of FAN OFF TIME.
Step 3: Now as per your requirement set time in Sec using UP/DOWN Key. After that press Enter
Key to Store a Data. Or Back key to come out without storing a Data.
Keys Configuration:
ENTER UP
BACK DN
Parameter Group:
Group
A0= FAN OFF TIME B0= REED TYPE C0= GROUD FLOOR DISPLAY
A1= DOOR BUZZER DELAY TIME B1= LOCK TYPE C1= FIRST FLOOR DISPLAY
A2= FAST TRAVEL TIME B2= RESERVE C2= SECOND FLOOR DISPLAY
A3= SLOW TRAVEL TIME B3= DOOR TYPE C3= THIRD FLOOR DISPLAY
A4= DO HOLD TIME B4= COLLECTIVE SELECTION C4=FOURTH FLOOR DISPLAY
A5= DC HOLD TIME B5= SPEED SELECTION C5=FIFTH FLOOR DISPLAY
A6= DO ON TIME B6= DC CONTINOUS C6-SIXTH FLOOR DISPLAY
A7= DC ON TIME B7= REED NO/NC C7= SEVENTH FLOOR DISPLAY
A8=LED HOLD TIME B8= UP DIRECTION LIMIT C8= RESERVE
NO/NC
A9= HALL CALL BUZZER TIME B9= DN DIRECTION LIMIT C9= RESERVE
NO/NC
AA=WAIT AT FLOOR BA= DO LIMIT NO/NC CA= RESERVE
AB=CAM STRIKE BB= DC LIMIT NO/NC CB= RESERVE
AC= DO/DC STRIKE BC= STOP NO/NC CC= RESERVE
AD= NO OF FLOOR BD= INS NO/NC CD= RESERVE
AE= FIRE FLOOR BE= PASSWORD CHANGE CE= RESERVE
AF= CARE COUNT BF= FACTORY RESET CF= RESERVE
Display Detail:
C0 Ground Floor 0
C1 First Floor 1
C2 Second Floor 2
To change the Floor Display as below segments.
C3 Third Floor 3
C4 Fourth Floor 4
0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,P,b,t,U,G,c,l
C5 Fifth Floor 5
C6 Sixth Floor 6
C7 Seventh Floor 7
Connection Diagram:
PIN DETAILS / TERMINAL DETAILS : RIGID V-02
UNIVERSAL CONTROLLER (V02)
(SITE WIRING DETAILS)