Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

V02 Universal Lift Card | Lift Controlling Panel

A-57, Pushp Industrial Park & Arcade,

Patel Mill Bus Stop,

Rakhial Cross Road, Rakhial,

Ahmedabad-380023

Gujarat, India.

Contact No: (079)22940100,9824166289

Email: rigid_controls@yahoo.co.in | Website: www.rigidcontrols.com


Features:
 No Of Floor
 G+7 Up/ Dn Collective
 G+5 Collective Selective
 Other
 Car Top/ Per Floor Reed
 Otis/Excel Lock
 Auto/Manual Door

Programming Step :

 Using Two Segments and 4 Keys Enter, Back, Up and Down. User can program the parameter. Press
the Enter key for 3 Sec to enter into Program Mode. Very first it will ask for password. After entering
password correct you can access board parameter. If password enters incorrect five times system gets
block off.
 All Parameter are divided in three group A,B,C.
 Using UP and DN key User can change group of parameter as per your requirement.
 And press enter key on your required group you will get list of parameter related that group.
 E.g. suppose you want to change a FAN Off timing.
 Step 1: Press Enter Key for 3 Sec you will get P on segment. After that enter a correct password. Then
go to Group A using UP/DN Key.
 Step 2: Press Enter On A Group you will got list of A group parameter. Now using UP/DOWN Key go
to A0 Parameter and press enter key you will get value of FAN OFF TIME.

 Step 3: Now as per your requirement set time in Sec using UP/DOWN Key. After that press Enter
Key to Store a Data. Or Back key to come out without storing a Data.

Keys Configuration:

ENTER UP

BACK DN
Parameter Group:

Group

GROUP A GROUP B GROUP C

A0= FAN OFF TIME B0= REED TYPE C0= GROUD FLOOR DISPLAY
A1= DOOR BUZZER DELAY TIME B1= LOCK TYPE C1= FIRST FLOOR DISPLAY
A2= FAST TRAVEL TIME B2= RESERVE C2= SECOND FLOOR DISPLAY
A3= SLOW TRAVEL TIME B3= DOOR TYPE C3= THIRD FLOOR DISPLAY
A4= DO HOLD TIME B4= COLLECTIVE SELECTION C4=FOURTH FLOOR DISPLAY
A5= DC HOLD TIME B5= SPEED SELECTION C5=FIFTH FLOOR DISPLAY
A6= DO ON TIME B6= DC CONTINOUS C6-SIXTH FLOOR DISPLAY
A7= DC ON TIME B7= REED NO/NC C7= SEVENTH FLOOR DISPLAY
A8=LED HOLD TIME B8= UP DIRECTION LIMIT C8= RESERVE
NO/NC
A9= HALL CALL BUZZER TIME B9= DN DIRECTION LIMIT C9= RESERVE
NO/NC
AA=WAIT AT FLOOR BA= DO LIMIT NO/NC CA= RESERVE
AB=CAM STRIKE BB= DC LIMIT NO/NC CB= RESERVE
AC= DO/DC STRIKE BC= STOP NO/NC CC= RESERVE
AD= NO OF FLOOR BD= INS NO/NC CD= RESERVE
AE= FIRE FLOOR BE= PASSWORD CHANGE CE= RESERVE
AF= CARE COUNT BF= FACTORY RESET CF= RESERVE

Display Detail:

No. Display Details


1 E This is error when you have entered wrong Password or parameter.
2 H This is error when you have entered wrong Password for 5 times.
3 P0 After this display you have to enter the Password.
4 = This is error for two Reed Short.
Parameter Table:

No. Name Description Default Range


This time started after all Car call become zero,
A0 Fan Off Time 10 Sec 0-99
interlock circuit ok.
This timer Started in Manual Door when Door
A1 Door Buzzer Time 2 Sec 0-99
Interlock is not Ok.
This timer started after Up or Down Fast
Command Come. If in between any Floor reed
A2 Fast Travel Time signal come they will restart. If time out occurs 0 Sec 0-99
it will stop the output. If it is 0 than no timer is
running.
This timer started after Reed single Middle/
Slow Command Come. If in between any Floor
Middle/Slow Travel
A3 Drive stop come they will restart. If time out 0 Sec 0-99
Time
occurs it will stop the output. If it is 0 than no
timer is running.
Time during which DO Command will remain on.
A4 DO Hold Time 15 Sec 5-99
After this time DO command become off.
Time during which DC Command will remain on.
A5 DC Hold Time 15 Sec 5-99
After this time DC command become off.
A6 DO On Time Door Open Command Operating Delay On Time. 1 Sec 0-99
A7 DC On Time Door Close Command Operating Delay On Time. 5 Sec 0-99
This timer work in attended mode for Hall call
A8 LED Hold Time led holding time. if it is 0 than LED will Clear on 5 Sec 0-99
that Floor.
A9 Hall Call Buzzer This timer Started after the hall call is given. 2 Sec 0-99
AA Wait At Floor Wait at floor between two calls. 5 Sec 3-99
No of time CAM open and close function retry
AB CAM Strike until the Landing Door Interlock is not ok in 5 3-99
Manual Door.
No of time Door open and close function retry
AC DO/DC Strike 5 3-99
until the Door Interlock is not ok in Auto Door.
AD No. Of Floor The number of floor in building. Ex. G + ... 7 1-7
In Fire Mode Lift will go the above selected
AE Fire Floor 0 0-7
floor.
After care count is activation lift will count the
no of times lift go for Ground floor if it equal to
AF Care Count 0 (0-99)X200
care count it will ask for maintenance. If the
selection is 0 than it will disable.
BO = 00 : Every Floor Reed
B0 Reed Type 0 0-1
BO = 01 : Car Top Reed
B1 = 00 : Otis Type Lock
B1 Lock Type 0 0-1
B1 = 01 : Excel Type Lock
B3 = 00 : Manual Door
B3 Door Type 0 0-1
B3= 01 : Automatic Door
B4 = 00: Down Collective
B4 Collective Selection B4 = 01 : Up Collective 0 0-2
B4 = 02 : Collective Selective
B5 = 00 : Single Speed
B5 Speed Selection B5 = 01 : Two Speed 1 0-2
B5= 02 : Three Speed(Above 1 Mtr/S Speed)
B6 = 00 : DC Signal off when lift is running
B6 DC Continuous B6 = 01 : DC Signal Continuous on when lift is 0 0-1
running
B7 = 00 : All Reed Switch = NO
B7 Reed Switch 0 0-1
B7 = 01 : All Reed Switch = NC
UP Direction Limit B8 = 00 : UP Final Direction Switch = NO
B8 0 0-1
Switch B8 = 01 : UP Final Direction Switch = NC
DN Direction Limit B9 = 00 : DN Final Direction Switch = NO
B9 0 0-1
Switch B9 = 01 : DN Final Direction Switch = NC
Door Open Limit BA = 00 : Door Open Limit Switch = NO
BA 0 0-1
Switch BA = 01 : Door Open Limit Switch = NC
Door Close Limit BB = 00 : Door Close Limit Switch = NO
BB 0 0-1
Switch BB = 01 : Door Close Limit Switch = NC
BC = 00 : Stop Button = NC
BC Stop Button 0 0-1
BC = 01 : Stop Button = NO
BD = 00 : Inspection Input = NO
BD Inspection Input 0 0-1
BD = 01 : Inspection Input = NC
BE Password Change To change the Password 00 0-99
For Factory Reset you have to enter a password
BF Factory Reset and wait a second all the default parameter will
be restore and restart the card.

C0 Ground Floor 0
C1 First Floor 1
C2 Second Floor 2
To change the Floor Display as below segments.
C3 Third Floor 3
C4 Fourth Floor 4
0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,P,b,t,U,G,c,l
C5 Fifth Floor 5
C6 Sixth Floor 6
C7 Seventh Floor 7
Connection Diagram:
PIN DETAILS / TERMINAL DETAILS : RIGID V-02
UNIVERSAL CONTROLLER (V02)
(SITE WIRING DETAILS)