Rev: B Page 1 of 9
Summary:
This document provides wall thickness measurement criteria for the Flowline
equipment. This document along with RPT50002000 also replaces Engineering
Bulletin 102C.
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 2 of 9
Engineering Bulletin
1.0 Scope
2.0 Background
Oil well pumping services such as hydraulic fracturing involve the movement of
slurries with abrasive solids at high flow rates. Over time, temporary piping equipment
can experience significant loss of pressure boundary wall thickness.
The minimum wall thickness values in the tables of this document are a result of a
consistent application of pressure boundary calculations per ASME Boiler and
Pressure Vessel Code Section VIII Division 2, and acceptance criteria in accordance
with API 6A for non-standard materials.
Never take FMC Flowline equipment above its rated working pressure.
The minimum wall thickness criteria in this document assume that rated
working pressure is never exceeded during operation, pre-job testing or
recertification for service.
WARNING
This document only provides wall thickness acceptance criteria. Actual inspection
methodology requirements such as inspection frequency, inspection scope and
acceptable measurement techniques are beyond the scope of this document. All
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 3 of 9
such inspection activity on Flowline products should be carried out in accordance with
Integrated Services procedures or other procedures approved by FMC.
When wall thickness measurements are taken, they must be compared with the
minimum allowable thickness for the product and feature per the applicable table(s)
within this document. If any inspected wall thickness falls at or below the specified
minimum allowable thickness, the component or product must be replaced. It is
highly recommended that the rate of erosion wear be analyzed to ensure that the
minimum wall thickness is not violated prior to the next scheduled inspection.
Use of temporary piping equipment with wall thickness in any area below
that specified in this document can result in death, severe injury and
significant property damage.
WARNING
Tables 4.1 through 4.4 on the following pages contain minimum wall thickness criteria
for Flowline products. These values apply to products manufactured specifically by
FMC.
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 4 of 9
Table 4.1: Minimum Eroded Wall Thickness for Various Swivel Joints in Bend and
Straight Areas (Not at Swivel or Male Sub End)
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 5 of 9
Table 4.2: Minimum Eroded Wall Thickness Under Male Ball Race for Swivel Joints
* Minimum wall for sour gas swivels are with snap-in races removed
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 6 of 9
Table 4.3: Minimum Eroded Wall Thickness for Detachable Wing Union behind Male
Sub Shoulder
Standard Sour Gas
Nominal Figure Service Service
Size Number Minimum Minimum
(Inches) (inches)
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 7 of 9
Table 4.4: Minimum Eroded Wall Thickness for Pup Joints in Tubular Area
Standard Sour Gas
Service Service
Figure Minimum Minimum
Nominal Size Number (Inches) (Inches)
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 8 of 9
Table 4.4: Minimum Eroded Wall Thickness for Pup Joints in Tubular Area (Continued)
Standard Sour Gas
Service Service
Figure Minimum Minimum
Nominal Size Number (Inches) (Inches)
Integral Pup Joints and Swivel Joint Hose Straight Pieces (Continued)
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Doc No: RPT50001989
Rev: B Page 9 of 9
Table 4.4: Minimum Eroded Wall Thickness for Pup Joints in Tubular Area (Continued)
Standard
Service
Figure Pressure Rating Minimum
Nominal Size Number (psi) (Inches)
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMCTI.