Reference modulus means that stiffness modulus calculated at all-around pressure equal to pref.
Plaxis uses 50% secant modulus. So, our procedure will be:
Perform triaxial test up to failure load qu at reference pressure (all-around pressure) pref.
Eref50=0.5quε1,50
An example calculation is given below. Calculated E50 = 30.8 MPa is valid for pref = 100 kPa. So,
when we define the material model in Plaxis, the default pref = 100 kPa value is correct for this case.