BSD104DV H3ax
BSD104DV H3ax
BSD104DV H3ax
2. General Specification
3. Drawings ———————10~23
BSD104DV-H3AX Drawing code Remarks
Q’ty
4CYCD0031 -
OUTLINE DWG. Dimensioned sketch
SC01D576 -
WIRING DIAGRAM
Electrical components
4CYC01003A 1 B130-160-241E
Motor protector
SC01D352H29 * 15µF-400WV
Running capacitor
SC01DA46 -
Terminal part assy
SC01DA53 1
Terminal cover
4CYC00995 1
Sleeve
SC01DA45 1
Motor Pro. Spring
SC01DA54 1
Packing
SC01DA63 1
Rubber washer
SC01D430 1
Flange nut
Mounting accessories
SC01DA55 -
Mount assy
SC01DA68 3
Rubber mount
1/23
BSD104DV-****
THE SPECIFICATION FOR BSD104DV-**** COMPRESSOR
SHEC-YG107
◆ 一 General specification
SLEC-EG013
◆ Compressor data
Current 1.92/1.97
3.0/2.85
COP
Conditions Evaporating temp. 7.2℃
2/23
THE GENERAL SPECIFICATIONS
FOR BSD***D* ROTARY COMPRESSOR
If a compressor is not operated properly, not only will it be impossible to display its performance to the full, but it
may lead to a shortened service life and even malfunctions and breakdowns. These operating instructions have
been prepared so that the rotary compressor will be used properly and efficiently without malfunctions and
breakdowns, and here lists the operation standards and handling precautions. It is recommended that you acquire a
full understanding of the special properties of the compressor and that you operate it properly.
(1) Refrigerant used. The HFC-134a (CH2FCF3) refrigerant must be used.Refrigerant R-134a
more than 99.95% in purity should be used for apparatus.
。 。
-10℃( 14 F ) to 25℃( 77 F) [0.20~0.66MPa]. The lower limit of this
(2) Evaporating 。
temperature may drop to -20 ℃ (-4 F) during the start of a heating
temperature range.
operation(2-3min) or during the transitional period between cooling /
heating selection with the heat-pump.
(3) Condensing 。 。
temperature range. The range is 28℃(82.4 F) to 70℃(158 F) [ 0.73~2.11MPa ].
SHEC-EG013 (1/4)
6/23
ITEM OPERATIONAL LIMIT
(11) Amount of
A maximum of 0.9Kg shall be charged. Its value is referential.
refrigerant charged.
The equipment shall be designed with less than 170,000 cycles in the
(12) ON/OFF frequency.
cooling and /or heating types.
The piping must be designed so that no damage will result from
transporting of the product and the ON/OFF of the compressor.
(13) Pipe stress.
At starting and stopping : 34.3N/mm2 (3.5kgf/mm2) or less
During operation : 17.7N/mm2 (1.8kgf/mm2) or less
2. Electrical parts
Use the designated electrical parts properly. The following electrical parts are used in a rotary
compressor and the specifications of each are given in the individual specification sheet of the compressor.
Dome mount type: connect the wires properly and mount inside the
box on the top f the compressor.
Motor protector Remote type: connect the wires properly and mount inside the
。
equipment {60℃(140 F) Max. Ambient temperature}.
Use capacitors with the required capacitance and withstanding
Running capacitor
voltage.
Starting capacitor
Use capacitors under the heat-withstanding temperature.
Use heat-resistant cable for the leads which are connected to the compressor terminal, motor protectors
(attached to compressor)
(Example) Ethylene tetrafluoride or polypropylene heaxafluoride resin cable.
Please use the lead terminal with soft insulation tube.
SHEC-EG013 (2/4)
7/23
3-4. Refrigerant charging method
The compressor is supplied with oil.
Create the vacuum from both the high and low pressure side. ( If it is possible to the create the vacuum
from one side only, take sufficient time at the high pressure side and check that the prescribed vacuum
gas has been created.)
Always charge the refrigerant from the high pressure side ( condenser ) of the unit.
3-7. Moisture
Keep the amount of balanced moisture inside the refrigeration circuit ( including compressor ) within
350mg(Cold-trap test).
Moisture level in the refrigeration system should be maintained as low as possible.
3-8. Evacuation
A degree of vacuum about 133Pa[abs] is desirable.
SHEC-EG013 (3/4)
8/23
3-13. Oil returns
It is important for the piping to be designed with sufficient consideration given to oil return during the
refrigeration cycle since the refrigeration oil in the compressor is sometimes discharged in volume inside the
equipment as a transitional phenomenon (due to the storing of the refrigerant ) during start-up, etc.
Oil is liable to collect when an auxiliary accumulator is attached within the refrigerating cycle, which
necessitates an oil-return structure. Care is required with short ON/OFF cycles. In the event of exceeding
the restricted amount and / or liquid flood back, it is mandatory that a properly sized accumulator and / or
crankcase heater be used.
Therefore confirm the oil level in the compressor with some sight-glasses. The oil level must be
confirmed during operation and on/off time and the confirmation shall be made under the condition where
there can be the lowest oil level; i. e. liquid refrigerant confinement, low ambient temperature.
4. Quality of compressor
4-1. Insulation
(1) Insulation resistance
Insulation resistance should be more than 50M between each of the terminals and the ground ( or the
shell ), and between each of the terminals with a megger.
(2) Dielectric withstand
A 50 or 60Hz potential as indicated below should be applied between live parts and dead metal parts.
1250v for 1 minute, or 1500v for 1 second ( Nominal 100~120v )
1500v for 1 minute, or 1800v for 1 second ( Nominal 200~240v )
4-3. Dryness
The inside of compressor is dried up. The remaining quantity of moisture measured by cold-trap
procedure should be below 120mg.
4-4. Cleanness
The inside of compressor is cleaned, there should be no dust or any harmful matter.
The compressors are proof against vibration and a shock in normal transportation.
SHEC-EG013 (4/4)
9/23