Table of Contents
Page
Capillary Tube
Thermostat
Type EGO
For building in 16A - 400V
Temp. Capillary Sensor Pole qty. Part no.
range length mm
50°C-300°C 830mm 3,1øx160 1* 31899
30°C-110°C 850mm 6øx115 1 31900
50°C-300°C 870mm 6øx75 3 31901
30°C-110°C 4930mm 6øx115 1 31902
50°C-300°C 830mm 3,1øx160 1 31903
50°C-300°C 2000mm 6øx80 3 319011
0°C-40°C 850mm 6øx147 1* 31923
0ºC-40ºC 870mm 6øx215 1 319230
0°C-145°C 1480mm 6øx98 3 31500
25°C-90°C 800mm 6øx92 1 31875
* with switch
Chromed front ring 31898
Chromed front ring for 31875 31878
Black setting button 0-40°C 31895
Black setting button 1-145°C 31520
Black setting button 30-110°C 31896
Black setting button 50-300°C 31897
Black setting button 30-110°C 31896
Application:
The EGO thermostat is equipped with 2 capillary tubes, one for the temperature range and one for the limiter temperature. Both
are lead into the same thermo well. When the limiter temperature has been reached, the thermostat must be
manually reset.
TR sensor
Reset button
Type 319221
The TR contact
can also be
closed at left
impact
TR sensor
Reset button
Temperature Limiter
Type EGO
Type EGO
For building in 16A
- 400V
Switch off Capillary Sensor Pole qty. Part no.
temperature length mm
140°C 1150mm 3,1øx156 1 31912
140°C 890mm 3,1øx188 3 31913
110°C 890mm 6øx94 3 31914
110°C 890mm 6øx73 1 319141
190°C 890mm 6øx77 3 31932
170°C 830mm 6øx73 1 31933
270°C 830mm 3,1øx160 1 91944
1000°C 830mm 6øx129 1 31880
36°C-110°C 830mm 6øx170 1 31881
20°C-150°C 2000mm 7øx128 1* 319121
* with change-over switch
• 20 amp rating
• Simple 2 wire connection
• Available in three standard lengths
Type VK 1-pole
Selection Guide
Model Stem Length Range (°C) Differential Voltage Current Rating (amps) Features
(°C)
VK4251 7"/178mm 10-88 10 230V AC 20A
VK4252 7"/178mm 10-88 10 230V AC 20A Pocket clip
VK4253 7"/178mm 40-110 10 230V AC 20A
VK4254 7"/178mm 40-110 10 230V AC 20A Pocket clip
VK4351 11"/280mm 40-88 6 230V AC 20A
VK4352 11"/280mm 40-88 6 230V AC 20A Pocket clip
VK4353 11"/280mm 70-120 6 230V AC 20A
VK4354 11"/280mm 70-120 6 230V AC 20A Pocket clip
VK4451 18"/457mm 55-85 5 230V AC 20A
Thermostat
Type 26150
Order no. Temp. range Switch ranges Packaging Thermostat incl. sensor
16150 -15°C...+150°C 3
Specification:
Power
90 - 250 VAC, 47-63 Hz, 12VA, 5W maximum
11-26 VAC/VDC, SELV, Limited Energy, 12VA, 5W maximum
Input 1 Characteristics
Resolution 18 bits
Sampling rate 5 times / second
Maximum rating -2 VDC minimum, 12 VDC maximum (1 minute for mA input)
Temperature effect ±1.5 uV/°C for all inputs except mA input, ±3.0 uV/°C for mA input
Sensor lead resistance T/C: 0.2uV/ohm
effect 3 wire RTD: 2.6°C/ohm of resistance difference of two leads
2 wire RTD: 2.6°C/ohm of resistance sum of two leads
Burn-out current 200nA
Common mode rejection 120dB
ratio (CMRR)
Normal mode rejection 55dB
ratio (NMRR)
Sensor break detection Sensor open for TC, RTD and mV inputs,
sensor short for RTD input,
below 1mA for 4-20mA input,
below 0.25V for 1-5V input, unavailable for other inputs
Sensor break responding Within 4 seconds for TC, RTD and mV inputs, 0.1 second for 4-20mA and 1-5V inputs
time
Linear Output
Resolution 15 bits
Output regulation 0.02% for full load
Output settling time 0.1 sec. (stable to 99.9%)
Isolation breakdown volt- 1000VAC
age
Temperature effect ±0.01% of SPAN / °C
Rating 1A / 240VAC
Inrush current 20A for 1 cycle
Min. load current 50mA rms
Max. off-state leakage 3mA rms
Max. on-state voltage 1.5V rms
Insulation resistance 1000 Mohms min. at 500 VDC
Dielectric strength 2500 VAC for 1 minute
Alarm (Output 2)
Alarm 1 relay Form C, max rating 2A/240VAC, life cycles 200,000 for resistive load.
Alarm functions Dwell timer
Deviation high / low alarm
Deviation band high / low alarm
Process high / low alarm
Alarm mode Normal, latching, hold, latching/hold
Dwell timer 0.1 - 4553.6 minutes
Data Communication
Interface RS-232 (1 unit), RS-485 (up to 247 units)
Protocol Modbus Protocol RTU mode
Address 1-247
Baud rate 2.4 ~ 38.4 Kbits/sec
Data Bits 7 or 8 bits
Parity Bit Non, Even or Odd
Stop Bit 1 or 2 bits
Communication buffer 160 bytes
Analog Retransmission
Output signal 4-20mA, 0-20mA, 0-1V, 0-5V, 1-5V, 0-10V
Resolution 15 bits
Accuracy ±0.05% of span ±0.0025%/°C
Load resistance 0-500 ohms (for current output), 10K ohm minimum (for voltage output)
Output regulation 0.01% for full load change
User Interface
Dual 4-digit LED Displays BTC-7100 Upper 0.4" (10mm)
Lower 0.31" (8mm)
Keypad 4 keys
Programming port For automatic setup, calibration and testing
Communication port Connection to PC for supervisory control
Digital Filter
Function First order
Time constant 0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds programmable
Approval standards
Safety UL 61010C-1, CSA C22.2 No. 24-93, EN61010-1 (IEC1010-1)
Protective class IP65 front panel with additional option
IP50 front panel without additional option
all indoor use
IP20 housing and terminals with protective cover
EMC EN61326
Ordering Codes
Thermostats
Type T 7000
T 7000
Electronic temperature control with PID return wiring; housing with
transparent cover; light diodes for net, operation and failure (sen-
sor failure); potential free switch 10A; temperature setting visual
from outside; direct connection of connection leads and heating
possible.
Connection
There are 4 product versions offering
different temperature ranges. The units
can be set to the following diagrams (see
section “Technical data” for more infor-
mation):
Standard setup:
Advantages:
• Individual use thanks to modular design
• Accurate temperature maintenance Type Designation
• Customized configuration possible.
ELT-GP1.1 LED-display, 230V, temp. controller for ELK...
Applications: (connection on both sides), wall-mounted 1 x
• Refineries M20, 2 x M16, 1 x M25, 1 x M12
• Chemical & petrochemical industries ELT-GP1.1 LED-display, 115V, temp. controller for ELK...
• Food processing industry (connection on both sides), wall-mounted 1 x
• Phamaceutical industry M20, 2 x M16, 1 x M25, 1 x M12
• Plastics industry
• Wastewater treatment plants ELT-GP1.2 LED-display, 230V, temp. controller for ELSR...
(connection on both sides), wall-mounted 3 x
M20, 1 x M16, 1 x M12
ELT-GP1.2 LED-display, 115V, temp. controller for ELSR...
Technical Data: (connection on both sides), wall-mounted 3 x
Nominal voltage.................................................... 230V, 50Hz M20, 1 x M16, 1 x M12
Power consumption................................................. Max 5VA
Controller temp. range................................. 0°C up to 100°C ELT-GP1-H16 LED-display, 230V, with 7-pole flange socket for
..................................................................... 0°C up to 200°C heating hoses and jackets, wall-mounted 3 x
..................................................................... 0°C up to 400°C M20, 1 x M16, 1 x M12
..................................................................... 0°C up to 800°C
Switching capacity........................................................... 16A
Accuracy with Pt 100............................+/-(0,5°K+0,5% v.M.) ELT-OAA 4-20 mA / 2-10V
With thermocouple type K.....................+/-(1,0°K+1,0% v.M.) ELT-OAA 0-20mA / 0-10V
With thermocouple type J.....................+/-(1,5°K+1,5% v.M.)
Resolution (internal).......................................... 0,1°C (Pt 100) ELT-OMR-1 2 x signal relay K3 and K4
............................................................ 0,4°C (Thermocouple) ELT-OMR-1 signal relay K3 (general fault)
Measurement current (Pt 100) .................... Approx. 0,75 mA
Enclosure..............Polycarbonate enclosure with transparent ELT-OMR-1 signal relay K4 (excess temperature)
............................................................cover and cable gland ELT-OLR 1 second load relay
IP rating........................................................................... IP65
Ambient conditions...........................................0° up to 40°C
............................. max. 90% rel. humidity (non-condensing)
Dimensions............................. 180 x 130 x 75 mm (w x h x d)
Optional extensions:
For ELT-GP1, -GP2 and -GP3
ELT-QAA........................... analogue output for ELT-GP-1/2/3
......................................................................0-20mA / 0-10V
......................................................................4-20mA / 2-10V
ELT-OMR-1....................... Signal relay for ELT-GP-1, 2 and 3
ELT-OLR 1.................................................. second load relay
.............................................(230V/max. 16A) for ELT-GP1+3
Advantages:
• Individual use thanks to modular design
• Accurate temperature maintenance
• Customized configuration possible. Type Designation
Optional extensions:
For ELT-GP1, -GP2 and -GP3
ELT-QAA........................... analogue output for ELT-GP-1/2/3
......................................................................0-20mA / 0-10V
......................................................................4-20mA / 2-10V
ELT-OMR-1....................... Signal relay for ELT-GP-1, 2 and 3
ELT-OLR 2.................................................. second load relay
.................................................(230V/max. 16A) for ELT-GP2
Advantages:
• Individual use thanks to modular design
• Accurate temperature maintenance Type Designation
• Customized configuration possible.
ELT-GP3 LED-display, 230V, controller/limiter combina-
Applications: tion Modutronic wall-mounted
• Refineries
• Chemical & petrochemical industries
• Food processing industry ELT-OAA 4-20 mA / 2-10V
• Phamaceutical industry ELTOAA 0-20mA / 0-10V
• Plastics industry
• Wastewater treatment plants ELT-OMR-1 2 x Signal relay K3 and K4
ELT-OMR-1 signal relay K3 (general fault)
ELT-OMR-1 signal relay K4 (excess temperature)
Technical Data: ELT-OLR 1 second load relay
Nominal voltage.................................................... 230V, 50Hz
Power consumption................................................. Max 5VA
Controller temp. range................................. 0°C up to 400°C
Switching capacity........................................................... 16A
Accuracy with Pt 100............................+/-(0,5°K+0,5% v.M.)
With thermocouple type K.....................+/-(1,0°K+1,0% v.M.)
With thermocouple type J.....................+/-(1,5°K+1,5% v.M.)
Resolution (internal).......................................... 0,1°C (Pt 100)
............................................................ 0,4°C (Thermocouple)
Measurement current (Pt 100) .................... Approx. 0,75 mA
Enclosure..............Polycarbonate enclosure with transparent
............................................................cover and cable gland
IP rating........................................................................... IP65
Ambient conditions...........................................0° up to 40°C
Dimensions........................... 213 x 185 x 118 mm (w x h x d)
Connections..... 30 cage pull-terminal screws, 2.5mm2 each
Cable entrance......... 2 x M20, 3 x M16, 2 x M12 loose items
Optional extensions:
For ELT-GP1, -GP2 and -GP3
ELT-QAA........................... analogue output for ELT-GP-1/2/3
......................................................................0-20mA / 0-10V
......................................................................4-20mA / 2-10V
ELT-OMR-1....................... Signal relay for ELT-GP-1, 2 and 3
ELT-OLR 1.................................................. second load relay
.............................................(230V/max. 16A) for ELT-GP1+3
Advantages: Function
• Weather proof If the sensed temperature is lower than the adjusted set point,
• Fixed switching set point the relay contact closes and the heating switches on.
Technical Data:
Supply voltage....................................... 230V, +/-10%, 50Hz,
..............................................optional voltages upon request
Switching capacity........................................................... 16A
Hysteresis..................................................... Approx. 1 Kelvin
Measurement input.............. Pt100 DIN 2-wire, with 5m PVC
......................................connecting cable (temp. max. 90°C)
Switching point ELTC/05............................... +3°C (set point)
Ambient temperature.....................................-30 up to +60°C
Control characteristics.......................... Dual mode controller
Output.............................................................1 relay contact
LED..........................................................Heating ON (yellow)
Enclosure......................................................... Polycarbonate
Dimensions...............................................130 x 130 x 75 mm
IP rating........................................................................... IP65
Weight............................................................................ 520g
Type Designation
ELTC 05 Incl. Pt 100, with 1 relay, 230V, 2xM25, 1xM12
ELTC 05 Incl. Pt 100, with 1 relay, 110V, 2xM25, 1xM12
ELTC 05 Incl. Pt 100, with 2 relay, 230V, 2xM25, 1xM12
ELTC 05 Without Pt 100, with 1 relay, 230V, 2xM25, 1xM12
Note: Versions for higher temperatures are available upon request.
Cable glands and terminals are provided for the power con-
nection. The unit is supplied in a weather proof plastic enclo- Sensors and display: It is possible to use two types of sensors,
sure, with a transparent cover. either Pt 100/2-wire or Pt 100/3-wire. Optional display of °C or °F
values. In case of use of a Pt 100/2-wire unit the actual tempeature
Advantages: value can be corrected. Range +/- 10K or +/- 18F, respectively. In
• LED display operable down to -25°C case of use of a Pt100/3-wire unit the temperature is automatically
• Programmable 0°C up to +390°C corrected. Also suitable for use with ELTF-PTEx 1 and 2 sensor.
• For switching 20 A resistive load with hybrid relay
• Signaling contact (configuable to operate either as alarm Relay configuation: Relay 1: regulator, relay 2: alarm/temperature
or release contact, potential-free) reached
• Suitable for Pt 100 with 2 or 3 wires
• For connection of up to 2 heating cables Temperature alarm: If the actual value deviates from the preset
• Operating voltage: 90-260 VAC / 50-60 Hz limit values, an alarm is given and transmitted via alarm relay K2.
Applications:
• Industrial applications
• Mechanical, electrical and plumbing (MEP) Type Designation
Technical Data: ELTC-14 Standard: Set with cable glands, reducer and blind
Operating voltage..................................90-260 VAC 50/60Hz cover.
Power consumption.......................................max 4mA < 5W
Switching capacity relay 1.....................20A with hybrid relay
Switching capacity relay 2...... 8A, changover contact (alarm)
Wiring digram
Operating temperature.....................................-25°C...+55°C
Storage temperature........................................-30°C...+60°C
Display range..................................................-50°C...+400°C
Adjustable range.......... 0°C...+390°C, optional configuration
Sensor connection............................... Pt 100 2-wire, 3-wire,
............................................................ optional configuration
Display.......................................................................LED, red
IP rating........................................................................... IP65
Dimensions..... 130 x 130 x 75 mm, polycarbonate enclosure
OP
31964
SN 300 001 4ø × 50 3 m comp. wire, 2-conductor. 31965
TEF 1J 6ø × 30 M10 × 1 Ermeto cable gland
DA
32315
TE
and 2 m comp. wire, 2-conductor
3.5ø × 30
RE
TEF 2J without cable gland, but with 32320
2 m glass silk-insulated wire
S?
TEF 4J 8ø × 12 3/8" bushing w/bajonet socket 31976
??
and 2 m comp. wire, 2-conductor.
TEF 11J 8/5ø × 10 W/bajonet socket and 32325
2 m comp. wire, 2-conductor.
TEF 12J 6ø × 5 M8 bushing, angle-bended and 31977
2 m comp. wire, 2-conductor
TEF 13J 14ø sensor M4 screw mounting and 32330
2 m comp. wire, 2-conductor.
TEF 14J 10ø sensor W/mounting angle, and 32335
2 m comp. wire, 2-conductor.
TEF 16J 8ø × 12 W/bajonet socket and 31978
2 m comp. wire, 2-conductor.
TEF 19J 6ø on Ms- F/found. in ring heating element 32340
cylinder and 2 m comp. wire, 2-conductor
TEF 2LJ 3.5ø × 35 W/fish-plate 15 × 8 × 1 mm and 31979
2 m comp. wire, 2-conductor.
TEF AJ 6ø on hold. F/mount. under the ring heat. elem. 32345
plate 15x30 mm and 2 m comp. wire, 2-conductor.
MT 1,5J 1.5ø × 90 1 m comp. wire, 2-conductor. 31894
TEF SpJ Clamp W/2 m comp. wire, 2-conductor. 32350
sensor for diametre 12-20 mm
9 mm band for diametre 16-25 mm 32352
width for diametre 20-32 mm 32354
for diametre 23-35 mm 32356
for diametre 25-40 mm 32358
for diametre 32-50 mm 32360
for diametre 40-60 mm 32362
for diametre 50-70 mm 32364
for diametre 60-80 mm 32366
for diametre 70-90 mm 32368
for diametre 80-100 mm 32370
for diametre 90-110 mm 32372
THERMO COUPLE Ni/CrNi (type K)
SN 400 000 6ø × 100 3 m comp. wire, 2-conductor 31966
KSK 2B20 2ø × 3300 W/plug 31938
KSK 2B20 2ø × 1500 W/plug 319381
KSK 2B20 2ø × 500 W/plug 31940
Type Element Nos of Un- Resis- Immer- Diameter Bayonet Nipple Mea- Lead Connec- Op.
Part no thermal grounded tance sion cap suring lengths tion type temp.
pairs junction sensor length surface
Thermocouple and
Resistance Sensor Designs
TEF 4 - Measuring Sensor TEF 4A - Measuring Sensor TEF 4B - Measuring Sensor
Type Element Nos of Un- Resis- Immer- Diameter Bayonet Nipple Mea- Lead Connec- Op.
Part no thermal grounded tance sion cap suring lengths tion type temp.
pairs junction sensor length surface
Type Element Nos of Un- Resis- Immer- Diameter Bayonet Nipple Mea- Lead Connec- Op.
Part no thermal grounded tance sion cap suring lengths tion type temp.
pairs junction sensor length surface
Thermocouple and
Resistance Sensor Designs
TEF 16 - Measuring Sensor TEF 16B - Measuring Sensor
Type Element Nos of Un- Resis- Immer- Diameter Bayonet Nipple Mea- Lead Connec- Op.
Part no thermal grounded tance sion cap suring lengths tion type temp.
pairs junction sensor length surface
TEF 16B Fe-CuNi 1 no - - 8mm Ø12,3mm - round 2000mm core end 300°C
Type L sleeve
TEF 16B Fe-CuNi 1 no - - 8mm Ø12,3mm - round 2000mm core end 300°C
Type J sleeve
TEF 16B NiCr-Ni 1 no - - 8mm Ø12,3mm - round 2000mm core end 300°C
Type L sleeve
X Providing technically possible (with B<34mm at edge; from 1) Crack protection spring Ø8x65
B>34mm at edge/central) 2) Bayonet cap
1) Standard design code no.: T19-002 3) Adjustable spring
2) Crack protection spring Ø8x65mm
3) Brass baffle plate
Type Element Nos of Un- Resis- Immer- Diameter Bayonet Nipple Mea- Lead Connec- Op.
Part no thermal grounded tance sion cap suring lengths tion type temp.
pairs junction sensor length surface
Remember! The table shows that in practice you can calculate a loop
Due to touch safety, all sensors must be installed as high voltage resistance of up to approx. 10-50 Ohm. For semi-conduc-
conductive mounting parts. tors the cable resistance will have no importance, but for
the resistance sensors, it will on many occations be necces-
sary to balance the cable resistance using a third conductor,
Example which makes a correction loop together with one of the
The thermostat EWTC 102 PTC DP is stated to have an accuracy main connections of the sensor element.
of ± 1ºC and solution 0.1ºC.
The sensor is connected by 35 m cable 2 × 0.5 mm2. The cable of the thermo couple sensors can only be exten-
Information is required concerning which influence this has on the ded by a compensation cable, i.e. a cable in same material
regulation accuracy. as the thermo element. The cable junction is made by
twisting the cleaned wires in equal material tightly to-
35 m 2 × 0.5 mm2 cable has the loop resistance gether and sliding a piece of insulation pipe over the junc-
0.35 × 7.02 Ohm = 2.36 Ohm. tion. Then the junc-tion is clamped in a terminal with thread
protection.
From the resistance characteristics on top of next page you can
se that 1 kOhm corresponds to a temperature change from -18 to Noice areas
+100ºC, totally 118ºC. The sensor cable increases the total resi- Normally you can say that the higher the resistance of the
stance in the circuit so that the display and thus the release point sensor element is, the less effected the measuring will be by
of the thermostat are moved upwards by: inducing streams of wires close to the sensor cable. Even
though, you ought to keep the sensor cable in appro-priate
2.46 × 118 distance from high voltage cables and avoid parallel siting.
C = 0.29ºC
1000
The resistance sensors Pt 100 and Ni 100 and the thermo
in relation to the actual sensor temperature. element sensors are more sensitive to noice and are there-
The thermostat must be adjusted to show approx. 0.3ºC less and fore delivered with a steel screen, which must be earth con-
following the accuracy will be ±1ºC again. nected at one end. On some occations the screen is left out
by short sensor cables.
Cable resistance
The noice sensitivity can be lowered some by using couple
Single Conductor Cable Loop twisted wires for extention of the sensor cable.
Cross section Ohm per Ohm per Length m per
mm2 100m 100m Ohm
Thermo couples are delivered according to the follow-
0.5 3.51 7.02 14.2 ing standards:
1.0 1.76 3.51 28.5 Fe/CuNi Type "J" black/white DIN IEC 584-1
1.5 1.17 2.34 43.0 Ni/CrNi Type "K" green/white DIN IEC 584-1
2.5 0.70 1.40 71.0 Resistance sensor:
4.0 0.44 0.88 114 Pt 100 Tolerance class "B" DIN IEC 751
Nipples
Nipple N4 Ø14,5mm Nipple N6/12 L35mm M10x1 Nipple N11 L50mm M14x1,5
Nipple N11 L100mm M14x1,5 Nipple N16 Ø12mm M10x1 Nipple N16 Ø12mm M12
Nipple N16 Ø12mm L25mm M12x1 Nipple N16 Ø12mm L25mm M12x1,5 Nipple N20/21 Ø12mm L35mm
M12x1
Nipple N20/21 Ø12mm L100mm M12x1 Nipple N20/21 Ø14mm M12x1 Nipple EN30 Ø12mm L60mm M12x1
Nipples
Nipple EN31 Ø9mm L50mm M14x1,5 Nipple EN32 Ø9mm L40mm M12x1 Nipple 32/25 Ø9mm L23mm M12x1
Nipple EN32/50 Ø12mm L23mm M12x1 EN32/60 Ø14mm M12x1 Nipple EN 32/80 Ø14mm L60mm
M12x1
Temperature Limits
Sensor element
0ºC Thermo couple type J 600ºC
Sensor pipe
-55ºC ABS 80ºC
-90ºC AISI 304 600ºC
Cable
THERMO COUPLE Ni/CrNi (type K)
TEMPERATURE SENSORS TEF 1K 6ø × 30 M10 × 1 Ermeto cable gland and 32380
2 m comp. wire, 2-conductor.
TEF 2K 3.5ø × 30 Without cable gland, but with 32385
2 m glass silk-insulated wire
TEF 4K 8ø × 12 3/8" bushing w/bajonet socket 3183
and 2 m comp. wire, 2-cond.
TEF 11K 8/5ø × 10 W/bajonet socket and 32390
2 m comp. wire, 2-conductor
TEF 12K 6ø × 5 M8 bushing, angle-bended 31892
and 2 m comp. wire, 2-cond.
TEF 13K 14ø sensor M4 screw mounting with 32395
DA
TEF 14K 10ø sensor W/mounting angle with 32400
TE
2 m comp. wire, 2-conductor
TEF 16K 8ø × 12 W/bajonet socket and 31891
RE
2 m comp. wire, 2-conductor
S?
TEF 19K 6ø on Ms- F/found. in the ring heat. elem. 32405
??
cylinder 2 m comp. wire, 2-conductor
TEF 2 LK 3.5 ø × 35 W/fish-plate 15 × 8 × 1 mm and 31890
2 m comp. wire, 2-conductor
25
10
50
Ø8,5
4
Ø9
R 1/4
10
M12×1
MULTI-PLUG
R3/8
M14×1,5 Ø11
M14×1,5
Type Pole qty. Description Part
no.
T 3200 2-pole 13ø w/thread 32430
T 3260 3-pole 13ø w/thread 32432
T 3300 4-pole 13ø w/thread 32434
T 3300-006 4-pole 13ø, angle plug, w/thread 32436
T 3079 3-pole 21ø w/thread 32438
T 3083 5-pole 21ø w/thread 32440
T 3008 3-pole 21ø w/bajonet lock 32442
T 3012 5-pole 21ø w/bajonet lock 32444
Specifications:
• Cable sensor for direct mouting or mounting for well
• Delivered for 2 - 3 - 4-wire connection
• Pt100 element DIN B, 1/3 DIN or 1/10 DIN m.m.
• Sensor pipe in stainless acidproof steel (AISI 316L)
• Max measuring temperature 150ºC, 300ºC or 600ºC
• Connection cable as steel braiding glass silk insulated, Teflon, PVC, Silicone or Polyurethan (PUR)
Ordering key: 94 - 0 - T - FF - 2 - DD - LL - G
Type Connection wire (T) Sensor type (FF) Material Diameter (DD) Length (LL) Cable length (G)
940 1 Metal braiding 60 Pt100 2-wire 150ºC 2 AISI 316 03 ø3,0mm 06 30mm 0 0,5m
2 Silicone 61 Pt100 3-wire 150ºC 04 ø4,0mm 07 35mm 1 1,0m
3 PVC 62 Pt100 4-wire 150ºC 05 ø5,0mm 08 40mm 2 1,5m
4 Polyurethan 65 Pt100 2-wire 300ºC 06 ø6,0mm 10 45mm 3 2,0m
(PUR)
66 Pt100 3-wire 300ºC 08 ø8,0mm 12 50mm 4 2,5m
6 Teflon 67 Pt100 4-wire 300ºC 10 ø10,0mm 14 60mm 5 3,0m
7 PVC w./shield 63 Pt100 2-wire 600ºC 12 ø12,0mm 18 80mm 6 4,0m
64 Pt100 3-wire 600ºC 14 ø14,0mm 22 100mm 7 5,0m
68 Pt100 1/3 DIN 4-wire 27 150mm 8 10,0m
71 Pt100 1/6 DIN 4-wire 30 180mm 9 Spec.
72 Pt100 1/10 DIN 4-wire 32 200mm
70 Pt500 37 250mm
80 Pt1000 42 300mm
50 Ni100 45 350mm
55 PTC-sensor (KTY81) 47 400mm
50 450mm
52 500mm
Other dimensions and sensor types available upon request. Sensor well etc can be delivered as accessories.
3 9
6
77
9 Terminals None
10 Filling None
Options With label
Technical data
Temperature range 0...+350°C
Accuracy Class B
Protection grade IP44
Response time K = 10" in liquid V=2m/s
Test
Traction test 2kg
Insulation 20Mohm @ 500V...
NOTES
(1) Various lengths can be requested. Contact the sales office for availability.
Specifications:
• Cable sensor for direct mounting or mounting in well
• Delivered with thermo cable for connection
• Thermo couple type J, L, or K
• Sensor pipe in stainless acidproof steel (AISI 316L)
• Max measuring temperature 150ºC, 300ºC or 600ºC
• Connection cable as steelbraiding glass silicone insulated, Teflon, PVC, Silocine or Polyurethan (PUR)
Ordering key: 94 - 0 - T - FF - 2 - DD - LL - G
Type Connection wire (T) Sensor type (FF) Material Diameter (DD) Length (LL) Cable length (G)
940 1 steel braiding 19 L Fe-CuNi ANSI 2 AISI 316 03 ø3,0mm 06 30mm 0 0,5m
2 Silicone 20 K NiCr-Ni insulated 04 ø4,0mm 07 35mm 1 1,0m
3 PVC 21 K NiCr-Ni 06 ø6,0mm 08 40mm 2 1,5m
4 Polyurethan 23 J Fe-CuNi DIN 08 ø8,0mm 10 45mm 3 2,0m
(PUR)
10 ø10,0mm 12 50mm 4 2,5m
6 Teflon 12 ø12,0mm 14 60mm 5 3,0m
7 PVC w./shield 18 80mm 6 4,0m
22 100mm 7 5,0m
27 150mm 8 10,0m
30 180mm
32 200mm
37 250mm
42 300mm
45 350mm
47 400mm
50 450mm
52 500mm
Other dimensions and sensor types avaliable on request. Sensor well etc. can be delivered as accessories.
Triac controller for electric heating, single phase or two phase. Supply air temperature control
For rapid temperature changes, PULSER will function as a PI con-
PULSER is an electric heating controller for controlling troller. The P band is 20 K and the I-time 6 min.
electric heating batteries, electric panels etc. The
controller can be connected to single phase or two phase Room temperature control
voltage, 210...415 V. For slow temperature changes, PULSER will work as a P controller
with a fixed proportional band of 2K.
Short facts about PULSER
• Complete electric heating controller with built-in sensor Night set-back
and setpoint adjustment. Using an external time switch, PULSER can provide an adjustable
• External sensor and external setpoint can be connected. night set-back. When closing the time-switch contact, the setpoint
• Control function adapts automatically, using PI for supply is lowered by the set value, 0...10K.
air control and P for room control.
• For loads up to 3.6kW (230 V) or 6.4kW (400 V). Controlling larger electrical outputs
• Automatic adaption to connected supply voltage When the electric battery or heater is larger than the capacity of
210...415 V. PULSER, the load can be split and controlled by PULSER in com-
• Adjustable night set-back, 0...10K. bination with the ancillary unit PULSER-ADD (see separate leaflet.)
Min/max adjustment
PULSER is an electric heating controller with triac control for When min/max limiting of supply air temp. is required, use PUL-
single phase or two phase electric heating. SER-M.
Intended primarily for wall mounting, it is connected in series
between a power supply and electric heater; such as an
electric heating battery or electric panel.
PULSER has a built-in temperature controller featuring
external sensor input, where the sensor can for instance be
mounted in a room or a supply-air duct. For control of room
temperature, the on-board sensor built into PULSER may be
used.
The controller uses time-proportional control, where the On-
time and Off-time ratio is varied to fit the prevailing heating
requirement. E.g. ON = 30 s and OFF = 30 s gives 50%
output power. The cycle-time (ie: combined on-/ off-time) is
fixed at approx. 60s.
This contributes to greater energy savings and to the incre-
ased comfort that an even temperature brings with it. Since
the current is switched by semiconductor (triac), there are no
moving parts that can wear out. Network disturbances are
also eliminated, as the current is switched at a zero phase
angle.
PULSER automatically adapts its control mode to suit the
dynamics of the controlled object.
Technical data
Supply voltage ................................................................................................... 210...415 V AC. 1- or 2-phase, automatic adaptation
Power output ........................................................................... Up to 16 A, min. 1 A. At 230 V, max output is 3.6 kW and min. output
...........................................................................................230 W. At 400 V, max. effect will be 6.4 kW and min. effect will be 400 W.
Power emission ........................................................................................................................................................... 20 W at full load
Ambient temperature .............................................................................................................................0...30°C with no condensation
Ambient humidity ............................................................................................................................................................. Max 90 % rH
Storage temperature ...........................................................................................................................................................-40...+50°C
Form of protection .......................................................................................................................................................................... IP20
Weight ......................................................................................................................................................................................... 0.3 kg
Low Voltage Directive (LVD) standards: This product conforms to the
requirements of the European Low Voltage Directive (LVD) 2006/95/EC
through product standards EN 60730-1 and EN 60730-2-9.
EMC emissions & immunity standards: This product conforms to the
requirements of the EMC Directive 2004/108/EC through product standards
EN 61000-6-1 and EN 61000-6-3.
RoHS: This product conforms to the Directive 2011/65/EU of the European
Parliament and of the Council.
Control unit parameters
Supply air control ...................................................................................................... PI function using P-band 20 K and I-time 6 min.
Room control ......................................................................................................................................... P function using P-band 1.5 K
Pulse period ....................................................................................................................................................................................60 s
Indicator ............................................................................... Red LED on bottom of PULSER, lit when power is pulsed to the heater
Sensor
Built-in sensor measurement range ......................................................................................................................................... 0...30°C
Input external sensor/setpoint ........................................... For our NTC sensors and setpoint devices. Temperature range depends
...................................................................................... on measuring range of sensor. The sensor connection has high ground zero
...................................................................................... potential and the installation should therefore follow standard mains voltage
.......................................................................................................................................................................... installation procedures.
Settings
Setpoint ............................................................................... 0...30°C. Knob with scale for other temperature ranges can be ordered.
Night set-back ........................................................................................................................................................................... 0...10 K
Night set-back
PULSER/D can provide night set-back via an external time
switch. On closure of the time-switch contact the PULSER
set-point is lowered by 5 K.
Technical data
General
Supply voltage ............................................................................200... 415 V AC 50-60 Hz, single or two phase. Automatic adaption
Power output ............................................................................................................................................ Maximum 16A, minimum 1A
Ambient temperature ....................................................... Maximum 40°C with no condensation. N.B. Pulser generates 20W of heat
Storage temperature .......................................................................................................................................................... -40 - +50°C
Ambient humidity .................................................................................................................................................... 90% RH maximum
Dimension (w x h x d) ................................................................................................................................................115 x 88 x 59 mm
Form of protection .......................................................................................................................................................................... IP20
This product conforms with the requirements of European EMC standards CENELEC
EN 50081-1 and EN 50082-1, European LVD standards IEC 669-1 and IEC 669-2-1
and carries the CE mark
Control unit parameters
Proportional band ................................................................................ 20K, fixed (Rapid temperature changes i.e. supply air control)
Reset time .................................................................................. 6 minutes, fixed (Rapid temperature changes i.e. supply air control)
Proportional band .............................................................................................2K, fixed (Slow temperature change i.e. room control)
Pulse period .............................................................................................................................................................. 60 seconds, fixed
Night set-back ................................................................................................................................................................................... 5K
Indicator ..................................................................................................................LED that is lit when power is pulsed to the heater
Inputs
Sensor .....................................................................................One (1) input for main sensor. See Section 6-100 for choice of sensor
Setpoint ..........................................................................Selectable, either internal setpoint potentiometer or external setting device
Setting
Setpoint ................................................................................0...30°C. The choice of sensor determines the controller setpoint range
Technical data
Supply voltage ......................................................................................... 3-phase, 210...255 / 380...415 V AC. Automatic adaptation
Power output ..................................................................................... Max. 25 A, min. 3 A/phase. At 400 V, max. effect will be 17 kW
Safety function ................................................................... The feed to the TTC should be interlocked with a high temp. limit switch
Power emission ........................................................................................................................................................... 45 W at full load
Cycle time ..................................................................................................................... Factory setting 60 sec. Adjustable 6...120 sec
Indicator .......................................................................................................................... Red LED, lit when power is pulsed to heater
Ambient temperature, operation .............................................................................................................................................. 0...40°C
Ambient humidity .............................................................................................................................................................. Max 90 %rH
Storage temperature ...........................................................................................................................................................-40...+50°C
Protection class .............................................................................................................................................................................. IP30
Low Voltage Directive (LVD) standards: This product conforms to the
requirements of the European Low Voltage Directive (LVD) 2006/95/EC
through product standard EN 60730-1.
EMC emissions & immunity standards: This product conforms to the
requirements of the EMC Directive 2004/108/EC through product standards
EN 61000-6-1 and EN 61000-6-3.
RoHS: This product conforms with the Directive 2011/65/EU of the European
Parliament and of the Council.
Control unit
Sensor inputs ........................................................................ Main and min./max. sensor. Min./max. sensor: working range 0...60°C
Main setpoint ..................................................................................................0...30°C. Other areas dependant on connected sensor.
............................................................................................................................................. Includes external setpoint (e.g. TG-R430)
Control parameters, primary control .................................... Rapid control circuits: PI-function with a P-band of 20K and I-time of 6
..................................................................................................... minutes. Slower control circuits: P-function with a P-band of 1.5 K
Setpoint, min. limitation ............................................................................................................................................................ 0...30°C
Setpoint, max. limitation ......................................................................................................................................................... 20...60°C
Control parameters, limitation ................................................................PI-function with a P-band of 20K and an I-time of 6 minutes
Output signal, controller ............................................. 0...10 V. Connected to control input of output unit by wire strap (terminal 7-9)
Dimensions
TTC25
3-phase controller for electric heating, be provided with a min. or max. limitation.
230 or 400 V / 25 A
TTC25 is a 3-phase controller intended for timeproportional Control of larger loads
control of electric heaters, radiators, etc. In cases where the electric heater is larger than the capacity
The controller is capable of controlling both D- and of TTC25, the load can be divided and controlled by use of
Y-connected loads. a TT-S4/D or TT-S6/D step controller in combination with the
• Built-in temperature controller with 0...10V signal for control of TTC25. See also product sheet for TTC40F.
output unit
• Automatic adaptation to connected 230 or 400V supply voltage TTC25X
• Model TTC25X is intended for control using an external 0...10V This electric heating controller is intended only for control
control signal using an external 0...10V control signal. For this reason, it
• For DIN-rail mounting does not offer a built in control unit. It is otherwise identical
• Settable min. and max. limitation to the TTC25.
• Adjustable cycle time
TTC25X
Control input ............................................................... For external control signal 0...10 V. No integrated control unit. No function for
.......................................................................................................................min. and max. limitation. Other technical data as above
Dimensions
Wiring
3-phase controller for electric heating, During room temperature control, the supply air temperature can
230 or 400 V / 40 A be provided with a min. or max. limitation.
TTC40F is a 3-phase controller intended for timeproportional
control of electric heaters, radiators, etc. Control of larger loads
The controller is capable of controlling both D- and In cases where the electric heater is larger than the capacity of
Y-connected loads. TTC40F, the load can be divided and controlled by use of a TT-
• Built-in temperature controller with 0...10V signal for con- S4/D or TT-S6/D step controller in combination with the TTC40F.
trol of output unit Slave control of one or more TTC25X / TTC40FX units via the
• Automatic adaptation to connected 230 or 400V supply TTC40F is also possible.
voltage TTC40FX
• Model TTC40FX is intended for control using an external This electric heating controller is intended only for control using an
0...10V control signal external 0...10V control signal. For this reason, it does not offer a
• For DIN-rail mounting built in control unit. It is otherwise identical to the TTC40F
• Settable min. and max. limitation
• Adjustable cycle time
Technical data
Supply voltage ......................................................................................... 3-phase, 210...255 / 380...415 V AC. Automatic adaptation
Power output ..................................................................................... Max. 40 A, min. 4 A/phase. At 400 V, max. effect will be 27 kW
Safety function ................................................................... The feed to the TTC should be interlocked with a high temp. limit switch
Power emission 7........................................................................................................................................................... 0 W at full load
Cycle time ....................................................................................................................... Factory setting 60 sec. Adjustable 6...60 sec
Indicator .......................................................................................................................... Red LED, lit when power is pulsed to heater
Ambient temperature, operation .............................................................................................................................................. 0...40°C
Ambient humidity .............................................................................................................................................................. Max 90 %rH
Storage temperature ...........................................................................................................................................................-40...+50°C
Protection class .............................................................................................................................................................................. IP20
Low Voltage Directive (LVD) standards: This product conforms to the
requirements of the European Low Voltage Directive (LVD) 2006/95/EC
through product standard EN 60730-1.
EMC emissions & immunity standards: This product conforms to the
requirements of the EMC Directive 2004/108/EC through product standards
EN 61000-6-1 and EN 61000-6-3.
RoHS: This product conforms with the Directive 2011/65/EU of the European
Parliament and of the Council.
Control unit
Sensor inputs ........................................................................ Main and min./max. sensor. Min./max. sensor: working range 0...60°C
Main setpoint ..................................................................................................0...30°C. Other areas dependant on connected sensor.
............................................................................................................................................. Includes external setpoint (e.g. TG-R430)
Control parameters, primary control .................................... Rapid control circuits: PI-function with a P-band of 20K and I-time of 6
..................................................................................................... minutes. Slower control circuits: P-function with a P-band of 1.5 K
Setpoint, min. limitation ............................................................................................................................................................ 0...30°C
Setpoint, max. limitation ......................................................................................................................................................... 20...60°C
Control parameters, limitation ................................................................PI-function with a P-band of 20K and an I-time of 6 minutes
Output signal, controller ............................................. 0...10 V. Connected to control input of output unit by wire strap (terminal 7-9)
TTC40FX
Control input ............................................................... For external control signal 0...10 V. No integrated control unit. No function for
.......................................................................................................................min. and max. limitation. Other technical data as above
Dimensions
TTC63F
Dimensions
Wiring
The ETO2 controller has been developped for ice and snow melting Remote control:
on the ground and in gutters. It is possible to control the ETO2 via an external signal (day/
Using readings from temperature and moisture sensors, the con- week timer, GSM module or other signal source).
troller ensures economical control of power consumption while The ETO2 can be switched on/off (standby) and the system
keeping outdoor areas and roofs free of ice and snow. The mois- can be temporarily forced to provide heat during the period
ture sensor should be installed in the ground surface or placed of time set in the afterrun menu.
in the gutter. As soon as moisture is detected in conjunction with
low temperature, the ETO2 controller activates the snow-melting Sensors:
system. ETOG Ground sensor:
Once the sensor has dried out, the thermostat immediately goes Designed for embedding into the surface of the outdoor
into afterrun and the system continues to provide heat for a set area. Measures temperature and moisture.
time. Up to two ETOG sensors can be installed.
32205 ETO2-4550 Thermostat incl. cover for wall ETF Outdoor temperature sensor:
surface mounting
Measures temperature. Is normally used in combina-
32212 ETOG-55 Ground sensor for measuring tem-
perature and moisture. 10m cable
tion with ETOR gutter sensor, but can also be used
32213 ETOG-56/ Ground sensor for embedding in
separately for temperature measurement only.
ETOK-1 outdoor surfaces, e.g. asphalt, An ETF sensor can also be used in combination with ETOG
25m cable ground sensors for outdoor areas The ETF sensor can
32210 ETOR-55 Gutter sensor for measuring mois- detect rapid drops in air temperature, thus avoiding icy
ture, 10m cable areas.
32214 ETF-744/99 Outdoor sensor for measuring
temperature
32206 ETO2-BOX UL mounting box for ETO2
• Process Heating
• Heating Elements
• Heating Cables
• Finned Tubular
Radiators
• Immersion Heaters
• Church Heating
• Frost Protection
• Ex-Material
• Oilfilled Radiators
• Drum Heaters
• Heating Pads
• Flow Heaters
• Air Duct Heaters
• High-voltage
• Resistors
• Controllers
With more than 50 years of experience SAN Electro Heat’s most valu-
able asset is special knowhow about design, product development and
manufacturing of professional electrical heating equipment for indus-
trial use.
www.san-as.com