Many decision factors need to be considered when selecting the appropriate signal
acquisition card for a TOF-MS project. Decision criteria embodies technological,
financial and risks management.
Two key TOF-MS characteristics are the accuracy of the mass measurement or charge-
to-mass ratio (m/z) and the data throughput or time to measurement. Acqiris acquisition
cards technology strongly contributes in mass/intensity accuracy, mass resolution and
mass sensitivity performance. More than a signal acquisition card, Acqiris aims at
improving the signal performances of your complete TOF-MS system.
Acqiris has experience and systems deployed in the field with a large range of TOF-MS
technology such as LC, GC, ICP, SIMS, MALDI-TOF and SLIM-TOF, both in the
research/quantization and in the clinical/quantification market.
Many decision factors need to be considered when selecting the appropriate signal
acquisition card for a TOF-MS project. Decision criteria embodies technological,
financial and risks management.
SA1 product line: Entry-level 8-bit 500 MS/s – 2 GS/s signal acquisition solutions
SA2 product line: Our New Medium to High-End range signal acquisition solutions
1. Achieve accuracy and throughput in mass measurement
Two key TOF-MS characteristics are the accuracy of the mass measurement or charge-
to-mass ratio (m/z) and the data throughput or time to measurement.
Mass Resolution: This very much depends on the bandwidth (BW), the sampling rate
(SR) and the flight time. High Mass Resolution implies that the signal acquisition card
shall not contribute to enlarge the detector pulse width FWHM (Full Width at Half
Maximum).
Mass Sensitivity: The Signal-to-Noise Ratio (SNR) limits the lowest concentration of a
substance where the signal can be distinguished from system noise. Averaging multiple
acquisitions can be used to improve the SNR but not it is not always possible, and it
lengthens the time to measurement. With proprietary analog design and specific TOF-
MS on-board processing, Acqiris provides solutions with the lowest possible SNR.
2. Reduce the total financial cost through your full project lifecycle
With a full range of products in various domains , and a large flexibility due to its
modular architecture, Acqiris offers solutions adapted to the customer innovation plans
at predictable cost. Acqiris assists from the earliest stages of system development until
the end of your product obsolescence in order for the customer to have a full control of
its budget throughout the full project’s life cycle.
With one slot short PCIe signal acquisition card, and versatile electronic interfaces to
reduce your system electronic, Acqiris also contributes to help you reduce the size and
the power consumption of your system.
4. Select the signal acquisition form-factor needed in your design
Acqiris gives flexibility when designing your TOF-MS systems by providing two different
form factors: PCIe card or serial-link enclosure. You select the version that either
provides fewer constraints on your external processors, or that ensures easy design
upgrades by “leveraging” a large part of your existing systems.