Professional Documents
Culture Documents
Vios - Task6and7 - Sump Pit and Calculations
Vios - Task6and7 - Sump Pit and Calculations
002
63
63
63 @ 1% 63 @ 1%
-0.34 (FROM TOP OF
BASEMENT SLAB)
16.823
STORM WATER
PERIMETER CANAL:
21.841
200mm WIDE
63
63
63
BASEMENT FLOOR
SUBDRAIN:
63 PVC PERFORATED STORM WATER
PIPE SERIES SUMP PIT
2.500
-0.22 (FROM TOP OF STORM WATER
BASEMENT SLAB) SUMP PIT
0.300
PIPE TO MANHOLE:
63 PVC PERFORATED
PIPE SERIES
TO EXITING
MANHOLE
1. DETERMINE THE (Q) DESIGN FLOW RATE 4. SOLVING FOR THE SLOPE/GRADIENT OF
THE STORM DRAIN (L)
Q= AXF
L=[1/ 4700 x diameter/ 4) ]100
wherein
A= AREA TO BE DRAINED IN SQ.M. AREA OF TRENCH DRAIN TO DIAMETER:
F= ESTIMATED STORM WATER FLOW; USE
0.0054 lps/m²
Ø= square root of 4a/3.14
Q= AXF Ø=0.113
Q= (16.8 X 15.0) (0.0054 lps/m²)
Q= 1.36 lps L=[1/ 4700 x diameter/ 4) ]100
L= 0.75% or 0.0075
A= AREA TO BE DRAINED
P= IMPERMEABILITY FACTOR; USE 1
R= RAINFALL RATE; ASSUME 0.125m/hr