# All are 13 digits non-PLU barcode unless stated #2 8 digit PLU barcode
#1 13 digits PLU barcode #3 8 digit non-PLU barcode
A2 - 1
SM 300 APPENDIX
SPEC 09 FIXED DATA FOR LEFT SIDE DATA OF TOTAL BARCODE
Please enter one number between 0 to 9 999 999 999
A2 - 2
SM 300 APPENDIX
SPEC 24 DEFAULT LABEL FORMAL FOR ITEM PRINTING
Standard U1, CA Standard U1, CA
0 T1 A 12 S T7
1 T2 B 13 A T8
2 T3 C 14 B T9
3 T4 U2 15 C T10
4 T5 U3 16 F1 F1
5 T6 U4 17 F2 F2
6 T7 U5 18 F3 F3
7 T8 U6 19 F4 F4
8 T9 U7 20 F5 F5
9 T10 U8 21 F6 F6
10 T11 T5 22 F7 F7
11 T12 T6 23 F8 F8
A2 - 3
SM 300 APPENDIX
SPEC 37* LABEL PRINT DENSITY (For SM-80SX/90/500)
0 Low 2 High mid
1 Mid 3 High
SPEC 41 UNIT PRICE OF WEIGH-PLU CAN USE FOR PRICE OF NON-WEIGHT-PLU AND VICE
VERSA
0 Allow 1 Inhibit
#Effective when SPEC 643 set to 4:Always
A2 - 4
SM 300 APPENDIX
SPEC 53 PARITY BIT OF SIO (RS232C PORT)
0 None 2 Even
1 Odd
SPEC 55 BAUD RATES OF MULTI-DROP SIO (RS485 / 4 LINE PORT) (For SM-80SX/90/SM-500)
0 1,200 3 9,600
1 2,400 4 19,200
2 4,800 5 38,400
SPEC 56 DATA LENGTH OF MULTI-DROP SIO (RS485 / 4 LINE PORT) (For SM-80SX/90/SM-500)
0 7 bits 1 8 bits
SPEC 57 PARITY BIT OF MULTI-DROP SIO (RS485 / 4 LINE PORT) (For SM-80SX/90/SM-500)
0 None 2 Even
1 Odd
SPEC 58 STOP BIT OF MULTI-DROP SIO (RS485 / 4 LINE PORT) (For SM-80SX/90/SM-500)
0 1 bit 1 2 bits
A2 - 5
SM 300 APPENDIX
SPEC 72 PACK DATE FUNCTION KEY ENABLE
0 Allow 1 Inhibit
A2 - 6
SM 300 APPENDIX
SPEC 92* PRINTER SPEED FOR LABEL (For SM-90)
0 Slow 2 High
1 Normal
SPEC 98 QUANTITY AND UNIT PRINT OUT FOR NON-WEIGH ITEM IN MANUAL MODE
0 Allow 1 Inhibit
SPEC 108 FIXED UNIT PRICE PERCENTAGE MARKDOWN FUNCTION KEY ENABLE
0 Allow 1 Inhibit
A2 - 7
SM 300 APPENDIX
SPEC 110 YEAR TYPE (For AA and TW only)
0 Standard 1 Japanese / Taiwan
SPEC 112 DEFAULT DATA OF PRINTING SPECIAL MESSAGE NUMBER FOR RECEIPT
Please enter one number from the range of 0 to 16
SPEC 115 TYPE OF ENTRY FOR USED-BY-DATE AND SELL-BY-DATE (For NICHII only)
0 By day 1 By hour
SPEC 116 BARCODE PRINTING IN FIRST LABEL FOR DUAL LABEL PRINTOUT (For NICHII only)
0 Print 1 No print
SPEC 118 BOTH PRICE BEFORE AND AFTER DISCOUNT (For NICHII only)
0 Price before and after discount 1 Price before discount only
A2 - 8
SM 300 APPENDIX
SPEC 129 TYPE OF HOST TO BE COMMUNICATED (Use With SPEC 128) (For SM-80SX/90/SM-500)
0 Standalone 2 POS ECR
1 TMR ECR
SPEC 130 PRINTING OF INGREDIENT, SPECIAL MESSAGE, PLACE, COMMODITY NAME, SELL-BY-
DATE AND TEXT ON PREPACK TOTAL LABEL
0 Based on status on item label 1 Based on status on manual total label
SPEC 133 CHANGE ALL PLU DEFAULT FORMAT WHEN DEFAULT SPEC CHANGE
0 Yes 1 No
SPEC 138 PERMANENT PRICE OR DISCOUNT PRICE CHANGE VIA FUNCTION KEY
0 No update to PLU 1 Update to PLU
SPEC 147 PREPACK NON ADD FUNCTION KEY ENABLE (Exclude AA)
0 Disable 1 Enable
A2 - 9
SM 300 APPENDIX
SPEC 148 FIS3000 CODE
0 SM 80 / 90 FIS3D 1 SM 25 FIS3D
SPEC 151 CHANGE SELL BY DATE AND USED BY DATE WHEN PACK DATED IS CHANGED
0 No 1 Yes
SPEC 153 USER PROGRAMMABLE RIGHT SIDE DATA FOR ITEM BARCODE
0 With identification digit 1 Without identification digit
A2 - 10
SM 300 APPENDIX
SPEC 169 PRINT PLU SETTING UNIT IN MANUAL MODE
0 No 1 Yes
SPEC 174 FIXED CLERK ASSIGN TO PRESET KEYS 8, 16, 24 OR 32 (For Bench type)
0 Clerk keys 1 Function keys
A2 - 11
SM 300 APPENDIX
SPEC 189 PLU AUTO DELETE
0 No delete 2 30 days
1 15 days 3 90 days
A2 - 12
SM 300 APPENDIX
SPEC 207 WEIGHT DECIMAL POINT POSITION FOR BARCODE AND LABEL PRINTING
0 Same as SPEC 607 1 0.000
# Effective only if SPEC 607 set to 2 : 0.00
SPEC 212 DEPARTMENT NUMBER FOR PICK 'N' PAY ( For SF Only)
Please enter a number between 1 to 99
SPEC 218 ZERO UNIT PRICE FOR UNIT PRICE CHANGE FUNCTION KEY
0 Disable 1 Enable
SPEC 222 OPEN CASH DRAWER WITHOUT SALES FUNCTION KEY ENABLE
0 Disable 1 Enable
A2 - 13
SM 300 APPENDIX
SPEC 226 REVERSE CALCULATION OF ITF CHECK DIGIT
0 No 1 Yes
SPEC 231 ZERO UNIT PRICE FOR PLU AND UNIT PRICE OVERRIDE
0 Inhibit 1 Allow
SPEC 245 PRINT SELL BY DATE OR USED BY DATE WHEN DATE = PACKED DATE
0 Yes 1 No
A2 - 14
SM 300 APPENDIX
SPEC 247 PRINT PACKED DATE
0 Manual and pre-pack mode 2 Pre-pack mode
1 Manual mode 3 No print
SPEC 256 DISPLAY PRICE WITH TAX AFTER CLERK KEY PRESS (For AA Only)
0 No 1 Yes
SPEC 257 UPDATE PRODUCTION NAME TO PLU VIA FUNCTION KEY (For AA Only)
0 No 1 Yes
A2 - 15
SM 300 APPENDIX
SPEC 266 FSD WEIGHT
0 Back computed (single range) 2 Back computed (single range)
1 Exact Weight
* For US only.
SPEC 268 DISPLAY SPECIAL SCALE MSG FOR DISCOUNTED ITEM (SM90)
0 No 1 Yes
* Not for AA, HK, CN, TW and KE.
SPEC 271 STORE TOTAL REPORT CLEAR (WHEN SPEC 270 ENABLE)
0 Clear store total report only 1 Clear all report
* This SPEC will function when SPEC 270 is enabled
A2 - 16
SM 300 APPENDIX
SPEC 282 BARCODE LOOK-UP-TABLE (LUT) FUNCTION
0 Disable 1 Speedup without LUT
2 LUT in memory 3 LUT in memory + File
A2 - 17
SM 300 APPENDIX
SPEC 304 SERVER PORT NUMBER
Range (1 ~ 255)
SPEC 318 WIRELESS FTP PORT NO. (V14.41 onwards for both SM90/500 & SM300 Spec 293, 294,
295, 296)
Range (1 ~ 9999)
SPEC 321 JULIAN DATE FOR PACKED & SELL DATE (*U1 VERSION ONLY)
0 No 1 Yes
SPEC 322 PRICE PRINTING SIZE (LARGE FONT) (VER 14.63 ONWARDS)
0 No 1 Yes
A2 - 18
SM 300 APPENDIX
10.2.2 WEIGHT & MEASUREMENT SPECIFICATION (REZERO + 1 4 2)
SPEC 600 PRICE BASE FOR PRICE CALCULATION FOR WEIGHED ITEMS
0 100g base 1 1 Kg base
SPEC 608 ZERO POINT SETTING RANGES WHEN A/C DISPLAY SWITCH ON
0 ± 10% of capacity 2 ± 2% of capacity
(Calibrated zero point ± 6000 IR) (Calibrated zero point ± 1200 IR)
1 ± 5% of capacity 3 ± 0.6% of capacity
(Calibrated zero point ± 3000 IR) (Calibrated zero point ± 360 IR)
SPEC 609 DECIMAL POINT FOR UNIT PRICE & TOTAL PRICE
0 None (00000) 2 0.00
1 0.0 3 0.000
SPEC 614 ZERO SETTING RANGES WHEN WEIGHT RESET SWITCH IS ON OR ZERO TRACKING
0 ± 10% of capacity 2 ± 2% of capacity
(Power on start point ± 6000 IR) (Power on start point ± 1200 IR)
1 ± 5% of capacity 3 ± 0.6% Of Capacity
(Power on start point ± 3000 IR) (Power on start point ± 360 IR)
A2 - 19
SM 300 APPENDIX
SPEC 615 CAPACITY
0 3 Kg 3 30 Kg
1 6 Kg 4 30 Lb
2 15 Kg
SPEC 619 PLU WEIGHT ITEM COMMODITY NAME DISPLAY (For Bench type)
(For SM-80SX/90/SM-500)
0 Full display 2 No display
1 Half display
SPEC 628 PRICE ROUNDING METHODS FOR THE DECIMAL DIGITS FOR WEIGHED ITEMS
0 Rounding 2 Cut up
1 Truncating
A2 - 20
SM 300 APPENDIX
SPEC 633 AUTO CLEAR OF TARE
0 Inhibit 1 Allow
SPEC 641 ACCUMULATION AVAILABLE ONLY AFTER SCALE SHOWS WEIGHT = ‘0’
0 No 1 Yes
A2 - 21
SM 300 APPENDIX
SPEC 651 CERTAIN FUNCTION KEY ORDER
0 Function key precede numeric key 1 Numeric key precede function key
SPEC 665 SWAP OF UNIT PRICE AND PRICE DISPLAY IN REGISTRATION MODE
0 No swap 1 Swap
SPEC 668* COMMODITY NAME DISPLAY INTERVAL (For SM-90 Bench type)
0 0.5 sec 2 1.5 sec
1 1.0 sec 3 2.0 sec
# OPTION 2 and 3 will be effective only if SPEC 619 is set to 0: FULL DISPLAY
A2 - 22
SM 300 APPENDIX
SPEC 668* 16 X 16 COMMODITY NAME (For SM-200 / SM-300)
0 1.0 sec display 2 2.0 sec display
1 1.5 sec display 3 2.5 sec display
SPEC 676 RIGHT SIDE BARCODE DATA RIGHT SHIFT FOR ITEM AND TOTAL BARCODE
0 No right shift 3 Left shift twice
1 Right shift 4 Left shift 3 times
2 Right shift twice
SPEC 678 PRINTING OF ITEM LABEL AFTER WEIGHT CHANGE (For Self Service type)
0 No print item label 1 Print item label
# Effective only if SPEC 640 or 641 set to 1
SPEC 680 TARE CLEAR WHEN EXIT FROM Z, PASSWORD MODE AND CHANGING OF CUSTOMER
AND WEIGHT AND MEASURE SPECIFICATION
0 No clear tare 1 Clear tare
A2 - 23
SM 300 APPENDIX
SPEC 684 CALIBRATION AT 1/5 OF THE CAPACITY
0 Disable 1 Enable
# Not effective when SPEC 615 set to 0:3kg