Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Sheet of To sheet Physical Layout Template

Mark N for north Customer Installer Panel Inverter Optimizer Issue: 02

Column
Row A B C D E F G H I J

1 Lable

Alias

2 Lable

Alias

3 Lable
To sheet

To sheet
Alias

4 Lable

Alias

5 Lable

Alias

6 Lable

Alias

To sheet
Physical Layout Usage Instructions: Pysical Layout Usage Examples:
The following shows the marks on the physical layout drawing.
If there are no PV modules, there is no need Example 1 (single drawing): Sheet 1 of 1 To sheet Physical Layout Template

to perform operations on the corresponding Installation positions of PV modules and optimizers. Mark N for north Customer Installer Panel Inverter Optimizer Issue: 02

square cells. String number Offset


1-4 1-6
column
row A B C D E F G H I J
SN: 2102311X SN: 2102311X
TGBTHC008676 TGBTHC008676
Y Y

1 Lable

String 1 Alias 1-4 1-6


SN: 2102311X SN: 2102311X
TGBTHC008676 TGBTHC008676
Y Y

2 Lable

Alias 2-2 2-4

If only PV modules are installed and optimizers 3 Lable

are not installed, black the dotted boxes in the

To sheet

To sheet
2-2 2-4 Alias

corresponding square cells of the PV modules. 4 Lable

String 2 Alias

5 Lable

Alias

6 Lable

Example 2 (multiple drawings): Alias

If PV modules are installed and optimizers are To sheet


Installation positions of PV modules and optimizers.
configured, remove labels from the optimizers
and attach them to the corresponding square 1-4 1-6 1-10 1-12
cells, then write an alias (you are advised to use
the string number and offset as the alias). String 1
Ensure that each QR code label is attached
within the square cell. X

SN: 2102311

2-2 2-4
TGBTHC008676
Y
2-8 2-10

String 2
String number x-x Offset
There are two labels on the optimizer, one
on the front and another on the back.
You can remove one of them. The following shows the marks on the physical layout drawing.
Sheet 1 of 2 To sheet Physical Layout Template Sheet 2 of 2 To sheet Physical Layout Template
Mark N for north Customer Installer Panel Inverter Optimizer Issue: 02 Mark N for north Customer Installer Panel Inverter Optimizer Issue: 02
SN: 2102311X
TGBTHC008676
Y

SN: 2102311X
TGBTHC008676
Y

column column
row A B C D E F G H I J row A B C D E F G H I J
SN: 2102311X SN: 2102311X SN: 2102311X SN: 2102311X
TGBTHC008676 TGBTHC008676 TGBTHC008676 TGBTHC008676
Y Y Y Y

1 Lable 1 Lable

Alias 1-4 1-6 1-10 Alias 1-12


SN: 2102311X SN: 2102311X SN: 2102311X SN: 2102311X
TGBTHC008676 TGBTHC008676 TGBTHC008676 TGBTHC008676
Y Y Y Y

2 Lable 2 Lable
SN: 2102311X
SN: 2102311X
TGBTHC008676
Y
TGBTHC008676
Y Alias 2-2 2-4 2-8 Alias 2-10

3 3

To sheet 2

To sheet 1
Lable Lable
To sheet

To sheet
Alias Alias

4 Lable 4 Lable

Alias Alias

5 Lable 5 Lable

Alias Alias

6 Lable 6 Lable

Alias Alias

To sheet To sheet

You might also like