Professional Documents
Culture Documents
ADU Construction Set
ADU Construction Set
ADU Construction Set
GENERAL NOTES
PROJECT DATA:
1. The Contractor shall provide adequate stays and bracing of all framing until all elements of design have been
PROJECT: incorporated in the project.
2. Contractor shall field verify all dimensions prior to commencing with new work.
OWNER:_______________________________________________ 3. Work under this permit does not require Special Inspection or structural observation.
4. If applicable fire walls should be provided and shall comply with section R302.
ADDRESS:______________________________________________ 5. Location of HVAC subject to field inspection.
6. HERS Verification required for the HVAC Cooling, HVAC Distribution, & HVAC Fan Systems per T24 Energy Calculation
APN NUMBER:____________________________
COLLABORATION WITH:
PLANS DEVELOPED IN
Documentation. Provide completed CalCerts Project Summary Report (PSR) as evidence of Third Party Verification (HERS)
STORIES: 1 to Building Inspector prior to final inspection.
COVER PAGE
A3 FOUNDATION PLAN
2019 CALIFORNIA BUILDING CODE (CBC) A4 BRACED WALL PLAN
A5 DETAILS
2019 CALIFORNIA RESIDENTIAL CODE (CRC)
A6 ROOF PLAN
2019 CALIFORNIA PLUMBING CODE (CPC) A7 ELEVATIONS
2019 CALIFORNIA MECHANICAL CODE (CMC)
2019 CALIFORNIA ELECTRIC CODE (CEC)
2019 CALIFORNIA EXISTING BUILDING CODE (CEBC)
PLANNING STAMP
PROJECT ADDRESS:
2019 CALIFORNIA ENERGY CODE
OWNER'S NAME:
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE
2019 CALIFORNIA FIRE CODE
OAKLAND MUNICIPAL CODE TITLES 15 and 17
SHEET:
A0.1
CALIFORNIA MECHANICAL CALIFORNIA ENERGY CODE NOTES CALGREEN CODE NOTES
CODE NOTES NEW CONSTRUCTION MANDATORY MEASURES (CALGREEN CH 4)
EXHAUST SYSTEMS 1. Mandatory measures of section 150 shall apply only to and/or within the 1. INDOOR WATER USE - (CALGreen Section 4.303) All new plumbing fixtures, or
specific area of the addition or alteration. (Energy Code Section 150.2) fixtures part of an addition or alteration shall comply with the following
1. Exhaust ducts shall terminate outside the building and be equipped with MANDATORY MEASURES (Energy Code Sections 110 & 150) mandatory allowable flow rates.
back draft dampers. (CMC Section 504.1) 2. MANDATORY REQUIREMENTS TO LIMIT AIR LEAKAGE (Energy Code Section
2. Kitchen range ventilation ducts shall be metal with smooth interior surfaces. MANDATORY FLOW RATE FOR NEW
110.7) - All joist penetrations, and other openings in the building envelope FIXTURE TYPE "WATER CONSERVING" FIXTURES
(CMC Section 504.3) that are potential source for air leakage shall be caulked, gasketed,
3. The clothes dryer shall be exhausted using approved 4" Ø min ducting. The SHOWERHEADS 1.8 GPM @ 80 PSI
weather-stripped or otherwise sealed to limit infiltration & exfiltration.
ducting shall not exceed 14' with a maximum of 2-90° elbows, unless 3. PHOTOVOLTAIC REQUIREMENTS LAVATORY FAUCETS 1.2 GPM @ 60 PSI
permitted by manufacturer instructions and the local jurisdiction. (CMC All low-rise residential buildings shall have a photovoltaic (PV) system KITCHEN FAUCETS 1.8 GPM @ 60 PPSI
Section 504.4) meeting the minimum requirements as specified in Joint Appendix JA11, GRAVITY TANK TYPE WATER CLOSETS 1.28 GAL/ FLUSH
4. No HVAC or water heater vents shall terminate less than 4'-0" below or to the with annual electrical output equal to or greater than the dwelling's
side, or less than 1'-0" above any door or operable window. (CMC Section annual electrical usage as determined by Equation 150.1-C
802.8.1) 4. PIPE INSULATION - (Energy Code Section 150 (j)) Hot water pipe insulation
COLLABORATION WITH:
shall have a minimum wall thickness of not less than the diameter of the
PLANS DEVELOPED IN
VENTILATION (Per CMC Section 402 & ASHRAE 62.2) pipe for a pipe up to 2" diameter. Insulate all pipes used to circulate hot A. When single shower fixtures are served by more than one shower-head,
water to kitchen fixtures, to a storage tank or between storage tanks. the combined flow rate of all the showerheads shall not exceed the
5. Kitchen - 100 cfm (On Demand), 1 SONE, 5" Ø min duct Insulate the first 5' of piping from the water heater. maximum flow rates specified.
6. Bathroom - 50 cfm (On Demand), 1 SONE, 4" Ø min duct 5. LIGHTING - (Energy Code Section 150 (k)) 3. ENHANCED DURABILITY AND REDUCED MAINTENANCE - (CALGreen 4.406)
Whole House - Per plans a. Efficacy - All installed luminaries shall be high-efficacy in accordance Annular spaces around pipes, electric cables, conduits or other openings in
Indoor Air Quality Fan - Per plans w/Table 150.0- A plates at exterior walls, shall be protected against the passage of rodents by
b. Recessed downlight luminaries in ceilings - All assemblies shall be IC closing such opening with cement mortar, concrete masonry or similar
APPLIANCES rated, AT rated, sealed, and comply w/ Joint Appendix JA8. Recessed method acceptable to the building official.
7. Appliances installed in attics shall be accessible through an opening and assemblies shall not contain screw base sockets. 4. POLLUTANT CONTROL - (CAL Green Section 4.504) At the time of rough
passageway at least as large as the largest component of the appliance c. Interior lighting, Switching Devices & Controls - Dimmers or vacancy installation, during storage on the construction site and until final startup of
and not less than 22" X 30" with minimum 30" headroom clearance. The sensors shall control all luminaries required to have a light source the heating, cooling and ventilating equipment, all duct and other related
appliance shall be located within 20' of the passageway access when attic compliant w/ Joint Appendix JA8. (Closets less than 70sf & hallways do air distribution component openings shall be covered with tape, plastic,
has less than 6' headroom. Passageway shall be unobstructed and shall not require dimmers or vacancy sensors). At least one luminaire in a sheet metal or other approved method to reduce the amount of water, dust
have solid flooring not less than 24" wide from the entrance to the bathrooms, garages, laundry rooms, and utility rooms shall be controlled and debris, which may enter the system.
appliance. A permanent 120- volt receptacle outlet and lighting fixture shall by an occupant or vacancy sensor. 5. INTERIOR MOISTURE CONTROL - (CALGreen Section 4.505) Building
be located at the entrance to the passageway. (CMC 304.4, CPC 509.4) d. Residential Outdoor Lighting - All fixtures shall be controlled by either materials with visible signs of moisture damage shall not be installed. Wall and
photocell & motion sensor, photocontrol & automatic time switch, floor framing shall not be enclosed when the framing members exceed 19
astronomical time clock, or EMCS. percent moisture content per CALGreen Section 4.505.3. Insulation products
6. HVAC - See Title 24 Energy Calculation Documentation which are visibly wet or have a high moisture content shall be replaced or
7. VENTILATION - (Energy Code Section 150(o)) All dwelling units shall meet allowed to dry prior to enclosure in wall or floor cavities. Wet- applied
the requirements of ASHRAE 62.2 SEE CALIFORNIA MECHANICAL NOTES. insulation products shall follow the manufacturer's drying recommendations
CALIFORNIA RESIDENTIAL prior to enclosure. Concrete slab foundations required to have a vapor
retarder and capillary break.
6. INDOOR AIR QUALITY - (CALGreen Section 4.506) Each bathroom shall be
CODE NOTES
GENERAL NOTES
mechanically ventilated with ENERGY STAR compliant fan. The fan shall be
controlled by a humidity control and ducted outside the building. The
WINDOWS humidity control shall be capable of adjustment between a relative humidity
range of 50 to 80 percent. A humidity control may utilized manual or
1. All new or replaced windows shall be dual glazed with low-E glass. Do not automatic means of adjustment. A humidity control may be a separate
remove NFRC stickers from glazing prior to approved inspection. Bedroom components to the exhaust fan and is not required to be integral.
windows shall have a minimum net clear escape opening of 5.7 SF with a 7. ENVIRONMENTAL COMFORT - (CALGreen Section 4.507) Perform residential
minimum net clear opening height of 24" and minimum net clear opening load calculations using ANSI/ACCA 2 Manual J approved methods or
width of 20". The window opening bottom edge shall not be more than 44" software. Size ducting in accordance with ANSI/ACCA 1 Manual D. Select
above the floor. (CRC Section R310) cooling equipment according to ANSI/ACCA 3 Manual S.
2. The Contractor shall provide safety glazing for all conditions deemed a
"hazardous location" per CRC Section R308.4.
BATHROOMS
PROJECT ADDRESS:
Board" is not acceptable in shower/ bathtub enclosures. Acceptable tile
based materials at shower/ bathtub enclosures include fiber cement, fiber
OWNER'S NAME:
mat reinforced concrete, glass mat gypsum backers, or fiber reinforced
gypsum backers. (CRC Section R702.4.2)
SHEET:
A0.2
19'-6"
CALIFORNIA PLUMBING CODE NOTES
8'-6" 1'-10" 9'-2"
WALL LEGEND GENERAL
1. Provide a back flow prevention device at all hose bibs and water
supply lines. (CPC 603.3)
2X6 WOOD STUDS @16" O.C. 1. Showers
Provide a back flow prevention device
2. and shower/ tub combinations shallathave
all hose bibs and
individual
2'-10" 6'-0" water
control supply
valves of lines. (CPC Section
the pressure balance, 603.3)
thermostatic or
5 2X4 WOOD STUDS @16" O.C.
2.combination
Showers and pressure
shower/balance/thermostatic
tub combinations mixing valve
shall have type.
individual
4
Provide temperature
control valves of theregulation
pressuretobalance,
limit hot water temperature
thermostatic or to
120°F. The waterpressure
combination heater thermostat shall not be considered
balance/thermostatic mixing valve
6 A5
appropriate means.
type. Provide (CPC 408.3)regulation to limit hot water
temperature
3040 H.S. GENERAL NOTES 3. Notemperature
Domestic dishwashing machine
to 120°F. The watershall be directly
heater thermostatconnected to
shall not
1. USE 'DUROCK', 'WONDERBOARD', OR a drainage system appropriate
be considered or food wastemeans.
disposer without
(CPC the use
Section of an
408.3)
AN APPROVED EQUAL BEHIND 3.approved dishwasher
The pressure air gap
absorbing fittingat
device onthe
thefollowing
dischargequick
side of the
acting
GLUED-ON TILE IN TUB, BATH, OR dishwashing machine. Listed air gapsmachines
shall be installed with units
the
4
3'-6"
valves: dishwashers and washing in dwelling
SHOWER AREAS. flood-level
7 shall be (FL) making at or aboveor the flood level of thedevices.
sink or
3020 H.S.(T)
4'-8"
2. SEPARATE SEWER LATERAL PERMIT wither air chambers listed mechanical
1 2 drainboard, whichever is higher. (CPC 807.3)
5'-10"
CLOSET
AND INSPECTIONS REQUIRED FROM (CPC Section 609.10)
4. Water closet stool shall be located minimum 15" from its center
5'-4"
15" 15" BATH DOT PRIOR TO CONNECTING.
3040 H.S.
to any side wall or obstruction (minimum 30" clear space in
MIN MIN BATHROOMS
COLLABORATION WITH:
PLANS DEVELOPED IN
width) and have a clear space in front of the water closet stool
2'-4"
MIN.
24"
not less than 24". (CPC 402.5)
4. Water closet stool shall be located minimum 15" from its
2 center to any side wall or obstruction (minimum 30" clear
space in width) and have a clear space in front of the water
closet stool not less than 24". (CPC 402.5)
CLOSET
3 3
3'-10"
3'-10"
8
LAUNDRY
DOOR AND FRAME SCHEDULE
3
22'-4"
22'-4"
13'-0"
REF
SIZE
4'-8" 3'-10" 2'-2" SYMBOL
WD HGT THK STYLE
1
8'-4"
3040 H.S.
KITCHEN
3030 H.S.
FLOOR PLAN
4'-8"
4'-4"
2
A4
60" X 30" TUB/SHOWER UNIT
1 SHOWER HEAD 1.8 GPM
3040 H.S.
2 TOILET 1.28 GPM
NOTE:
(1) ALL HEADERS AT EXTERIOR DOOR AND WINDOW
OPENINGS SHALL BE 4X8 D.F. #2 MIN.
3 22"X30" ATTIC ACCESS PANEL
PROJECT ADDRESS:
8'-3" 3'-0" 8'-3"
AC CONDENSER
(3) ALL WINDOWS SHALL HAVE A MAX. WINDOW HEIGHT OF
OWNER'S NAME:
84"
19'-6" 6 EXTERIOR WATER HEATER
EXT. TANK-LESS W/H
SHEET:
CEILING FAN WITH HIGH EFFICACY 1. Provide UFER ground located at main service panel per CEC Article
LIGHT FIXTURE 250.50.
EXT. TANK-LESS
W/H W/ DEDICATED 1"
GAS PIPE CIRCUITS
S SINGLE WALL SWITCH
120V
GFCI
WP 2. Provide two minimum separate amp circuit to kitchen appliances.
SVS (CEC Article 220.52 (A)).
WALL SWITCH WITH VACANCY SENSOR
3. Provide one minimum 20 amp circuit to laundry appliances. (CEC
Article 220.52 (B)).
WALL SWITCH EQUIPPED WITH A
SMS 4. At least one bathroom receptacle outlet supplied by at least one
MOTION SENSOR AND PHOTOCONTROL
20-amp branch circuit shall be located within 3' of the af the basin
TWO-WAY SWITCH
edge. Such circuits shall have no other outlets. (CEC Article 210.52 (D))
S3
5. The following receptacles shall be GFCI protected (CEC Article 210.8):
VF
COLLABORATION WITH:
a. Bathrooms
PLANS DEVELOPED IN
TELEPHONE JACK b. Garages
SSVS c. Outdoors
d. Kitchens- where the receptacles are installed to serve the countertop
S3
TELEVISION JACK e. Within 6' of sink basins
240V f. Laundry Rooms
120V
GAS
+48 AFF 6. All branch circuits that supply 120-volt, single phase, and 15 and 20
VF amp outlets installed in dwelling unit kitchens, family rooms, dining
SS
HOSE BIB (LOCATE IN FIELD) SSVS
rooms, living rooms, dens, bedrooms, closets, hallways, and laundry
areas shall be protected by a listed arc-fault circuit interrupter. (CEC
PROVIDE SWITCH & Article 210.12)
2' X 4' LED PANEL RECEPTACLE OUTLET
IN ATTIC SPACE RECEPTACLES
ELECTRICAL PLAN
GFCI
the front & back at no more than 6.5' above grade
PROVIDE (1) GFCI & AFCI
SWITCH CONTROLLED RECEPTACLE OUTLET PROTECTED RECEPTACLE
LIGHTING
OUTLET FOR RANGE &
SS
PROJECT ADDRESS:
SHALL BE TAMPER RESISTANT
3. Provide a minimum 30" wide by 36" deep by 6 21 ' high illuminated clear
working area shall be provided in front of each panel.
OWNER'S NAME:
ELECTRICAL PLAN SHEET:
3'-0"
FOUNDATION NOTES:
1'
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF
2,500 PSI AT 28 DAYS. (R402.2)
COLLABORATION WITH:
PLANS DEVELOPED IN
2X6 D.F.#2 STUD @ 16" O.C. ATTACH TOP PLATE
TO CEILING JOIST W/
(2) 16d COMMON END NAILS
1
2" GYPSUM BOARD W/
SAND, OVER 10 MIL VAPOR BARRIER, 5d COOLER NAIL 7" O.C.
1
2" GYPSUM BOARD
OVER 4" AGGREGATE BASE FOR EDGES & FIELD
3
8" PLYWOOD SHEATHING
OR OSB
MIN.
3.5"
FOUNDATION PLAN
A6 NON BEARING WALL FRAMING
A3
1'
-1.5"
3'-0"
3'-0"
PROJECT ADDRESS:
4'-9" 10'-0" 4'-9"
OWNER'S NAME:
19'-6"
L = 12'-0" L = 4'-6"
A B
BRACED WALL PANEL SCHEDULE CS- CS-
COLLABORATION WITH:
WSP WSP
PLANS DEVELOPED IN
MINIMUM
METHOD THICKNESS FASTENERS EDGE FIELD
1 1
EXTERIOR SHEATHING
L = 3'-0"
L =3'-2"
PER TABLE 602.3(3)
WSP
CS-
WSP
6" O.C. 12" O.C.
CS-
1
CS-WSP 2" OSB
INTERIOR SHEATHING
PER TABLE 602.3(1) OR
602.3(2)
4
A5
L = 11'-6"
WSP
CS-
L =10'-0"
22'-4"
WSP
CS-
WSP
L =3'-2"
CS-
WSP
CS-
2 2
PROJECT ADDRESS:
OWNER'S NAME:
CS- CS- CS-
WSP WSP WSP
COLLABORATION WITH:
PLANS DEVELOPED IN
BEARING WALL
DETAILS
PERPENDICULAR
14
6" MINIMUM
13. R-19 IN STUD CAVITY DEPTH, D
CLEARANCE
14. 2X6 D.F. #2 BOTTOM PLATE (PRESSURE-TREATED WHEN IN 3 15
TO GRADE
CONTACT WITH CONCRETE) WITH 58" X 10" ANCHOR BOLT @
4' O.C. MAX (MIN. TWO BOLTS PER SILL SECTION) 2
15. 4" CONCRETE SLAB 2,500 PSI MINIMUM REINFORCED WITH A
D/4 MAX.
7"MIN.
6"
MINIMUM OF 6X6 #10 GAUGE WELDED WIRE REINFORCING
MESH CENTERED IN SLAB OVER 10MIL VAPOR BARRIER,
16 (CRC 802.7.1)
12"
OVER 2" SAND, OVER 4" AGGREGATE BASE
16. 4" SAND/ GRAVEL MIN.
1 12"
PROJECT ADDRESS:
18" BELOW 3.2 RAFTER NOTCH
OWNER'S NAME:
NATURAL GRADE A5
DETAILS SHEET:
(3)16d
PLACE SOLAR PANELS
IN MOST OPTIMAL POSITION
45° 2X4 CONT. ACROSS 2.09 KWdc
(3) 16d
TRUSS. (3)16d PER
GABLE STUD 5:12 5:12
NEW ROOF:
2X4 BRACE @ 6'-0" W/ RADIANT BARRIER SHEATHING
TO BLK'G @ ROOF
72" HIGH MAX. @ NON
COLLABORATION WITH:
SHEATHING
PLANS DEVELOPED IN
(1)A35 CLIP
STRUCT. GABLES. 48" COOL ROOF SHINGLES
O.C. MAX. @ STRUCT.
2X6 CONT.
NEW WINDOWS:
U-FACTOR: 0.3
16d @ 6" O.C. COOL ROOF ASPHALT
2X4 CONT. BACKING COMPOSITION SHINGLES OV.
NAIL W/ 16d @ 6" O.C. GABLE END WALL 2X6 D.F. #2 RAFTERS @24" ON CENTER W/ 2X8
PER PLAN
1'
15 LB. ROOFING FELT OVER 7 16 RIDGE BOARD, W/ 1X4 COLLAR TIES
O.S.B SHEATHING W/ RADIANT CONNECTED IN THE UPPER TIER OF THE ATTIC
24'-4"
5 GABLE END DETAIL BARRIER
@48" ON CENTER MINIMUM
A6
CEILING JOISTS 2X10 D.F. #2 @ 24" O.C.
ROOF PLAN
(435/150) = 2.9 SQ FT.
2.9 X 144 = 417.6 SQ IN.
1 1
A5 A5
NOTE: EVENLY DISTRIBUTE EAVE VENTS
1'
PROJECT ADDRESS:
OWNER'S NAME:
ROOF PLAN SHEET:
COLLABORATION WITH:
3040 3040 3040
PLANS DEVELOPED IN
FINISHED FLOOR 0'-0"
FRONT RIGHT
ROOFING COVERING:
CRRC COMPLIANT ASPHALT COMPOSITION
SHINGLES OVER 15# FELT UNDERLAYMENT WHICH
SHALL BE LAPPED 2 INCHES AND END LAPPED
AT 4” AND OFFSET BY 6 FEET. (TABLE R905.1.1(2))
ELEVATIONS
STUCCO
3020 (T)
3030 3-COAT STUCCO OVER ONE LAYER OF
3040 NO. 15 ASPHALT FELT. WHEN APPLIED
OVER WOOD-BASED SHEATHING,
SHALL INCLUDE A WATER-RESISTIVE
VAPOR-PERMEABLE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT
TO TWO LAYERS OF GRADE D PAPER.
(R702.1(2), R703.2, R703.7.3)
PROJECT ADDRESS:
OPTION:
1
2" MIN. WOOD SIDING
BACK LEFT
OWNER'S NAME:
WINDOWS AND DOORS NOT
TO BE HIGHER THAN 80"
ELEVATIONS SHEET:
1
4" = 1'-0" A7