MATERIAL SPECIFICATION

PLUMBING NOTES
COLD WATER LINE
SHALL BE POLYPROPYLENE RANDOM PIPE (PPR-PN16)
LEGEND AND SYMBOLS
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED TO THE SEWER LINE
PROVISIONS OF THE NATIONAL PLUMBING CODE, THE NATIONAL BUILDING SHALL BE POLYVINYL CHLORIDE(PVC) PIPE SERIES 1000 HIGH IMPACT
CODE OF THE PHILIPPINES, AND RULES AND REGULATIONS OF CITY OR FAU FAUCET SIMILAR TO NELTEX, EMERALD, CROWN BRAND OR APPROVED EQUAL
MUNICIPALITY WITH JURISDICTION FD FLOOR DRAIN

2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND LAV LAVATORY VENT LINE
SPECIFICATIONS. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY WC WATER CLOSET
SHALL BE POLYVINYL CHLORIDE(PVC) PIPE SERIES 600
DISCREPANCY FOUND HEREIN. SIMILAR TO NELTEX, EMERALD, CROWN BRAND
URI URINAL
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY GV GATE VALVE
RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER TRADES SHALL BE SHO SHOWER HEAD DOWN SPOUT
WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. KS KITCHEN SINK
SHALL BE POLYVINYL CHLORIDE(PVC) PIPE SERIES 1000 HIGH IMPACT
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL HB HOSE BIBB
SIMILAR TO NELTEX, EMERALD, CROWN BRAND
LOCATION, DEPTHS, AND INVERT ELEVATION OF EXISTING PIPES AND SF SINK FAUCET
STRUCTURES AS VERIFIED BY THE CONRTACTOR. VTR VENT THRU ROOF WATER METER PLUMBING
CB CATCH BASIN
SIMILAR TO BADGER AND ASM
5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 0.50% AS
MINIMUM UNLESS OTHERWISE SPECIFIED. CO CLEAN OUT
GATE VALVE
6. SIZES OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE DS DOWN SPOUT SIMILAR TO KITZ, NECO OR APPROVED EQUAL
WITH THE MANUFACTURING INSTRUCTIONS. PPR-PN16 WATER SUPPLY

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND SITE DRAINAGE LINE SITE STORM DRAINAGE LINE
COORDINATE THE WORKS WITH THE SEWER DISPOSAL POINT AND WATERLINE WASTE PIPE/SANITARY LINE SHALL BE POLYVINYL CHLORIDE, PVC (>250MM)
SERVICE CONNECTING POINT. WATER METER SHALL BE REINFORCED CONCRETE PIPE , RCP (> 230MM)
8. ALL FIXTURES SHALL BE VERIFIED, UNLESS OTHERWISE NOTED. GV
GATE VALVE P-TRAP
9. THE WORK SHALL BE EXECUTED IN THE BEST AND MOST THOROUGH CV SHALL BE STAINLESS STEEL, AND/OR DURABLE CHROME PLATED
CHECK VALVE
MANNER KNOWN TO THE TRADE AND TO THE SATISFACTION OF THE ARCHITECT
/ ENGINEER. WATER CLOSET
SHALL BE DUAL FLUSH TYPE AND HAS ANTIBACTERIAL SEAT

FAUCET
SHALL BE LEVER TYPE STAINLESS STEEL

TO SEWER LINE
CB
250MM Ø PVC
TO PUBLIC DRAINAGE
100 MM

LINE OF ROOF ABOVE


CB
Ø PVC

LINE OF ROOF ABOVE

250MM Ø PVC
D D D
02 02 02

20MM Ø PN-16
D D D
01 01 01
100 MM

CB
Ø PVC

D D D
LINE OF ROOF ABOVE

01 01 01

250MM Ø PVC
D
02

CB

250MM Ø PVC
250MM Ø PVC
GV
TO PUBLIC DRAINAGE
TO PUBLIC DRAINAGE
WM
M DRAIN LINE LAYOUT
SEWER LINE LAYOUT SEWER LINE LAYOUT
SCALE 1:150mts.
SCALE 1:150mts. SCALE 1:150mts.

PREPARED BY: CHECKED BY: REVIEWED BY: NOTED BY: APPROVED BY: PROJECT TITLE AND LOCATION: SHEET CONTENT: SHEET NO:
REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF SOCIAL WELFARE AND DEVELOPMENT CONSTRUCTION OF BARANGAY ISOLATION UNIT 7


ENGR. EMMANUEL D. DE LOS REYES JR. ENGR. MICHELLE S. ARCILLAS ENGR. NILO T. HINOJALES ENGR. AMOR P. AMARAN LUCILLE TORILLA AT AJUY VILLE AS SHOWN
REGION VI 8
mct-technical facilitator act-technical facilitator MUNICIPAL ENGINEER PROJECT DEVELOPMENT OFFICER IV BDC-TWG CHAIRPERSON AJUY VILLE BARANGAY POBLACION, AJUY, ILOILO