Revision Qty

and Rate as per


market
Sr. No. Name Amount 20.06.2022
1 FAS -
2 PA -
3 Talk Back -
TOTAL - -
BILL OF QUANTITIES For FIRE ALARM & PUBLIC ADDRESS SYSTEM WORKS - Prakash Jain Residences
CONTRACTOR SCOPE SHALL BE AS BELOW:
1. CONTRACTOR TO PERFORM DESIGN VERIFICATION/VALIDATION.
2. EQUIPMENT SELECTION SHALL BE SUBMITTED FOR CONSULTANT/CLIENT APPROVAL PRIOR TO PROCUREMENT. Rate
Sr.No DESCRIPTION UNIT QTY Rate per unit Amount Morley Make Model No
Supply Installation
1 FIRE DETECTION AND ALARM SYSTEM
1.1 2 loop Control Panel with battery backup (DXc2) EN listed Set 1 714/001/225 (DXc2)
Not Required - Inbuild in
1.2 Loop Card Nos. RO
control panel

1.3 Analogue, Addressable, Photo electric (Optical) type Smoke Detector with original base. Nos. 115 HM/PSE/S2 + MI/B501AP/IV

1.4 Analogue, Addressable, Multi Sensors - Rate of rise type (EN) with original base. Nos. 3 HM/PTSE + MI/B501AP/IV

Conventional GAS Detector +


Analogue, Addressable, Photo electric (Optical) type Gas Detector (EN) with original base. Nos. 5
1.5 Zone module

1.6 Analogue, Addressable, Heat Detector - Rate of rise type (EN) with original base. Nos. 10 HM/RHSE + MI/B501AP/IV

Supply,Installation,Testing & Commissioning of Analogue Addressable Flash scan intelligent, addressable


reflected beam smoke detectors for protecting open areasListed to UL 268, ULC CAN/ULC S529. The
detecor should have Transmitter/receiver built into same unit, Six user-selectable sensitivity levels, Built-in
1.7 Nos. RO
automatic gain control compensates for signal deterioration from dust buildup, The detector shall be capable to
address in the range of 1-159. The detector shall be with Visible bi-color LEDs for 360 deg viewing and shall
blink green every time the detector is addressed, and illuminate steady red on

1.8 Response indicator for all detectors located above false ceiling. Nos. 2 Local RI
Supply,Installation,Testing & Commissioning of Addressable Break Glass / Manual Call Point having
Rotary, decimal addressing system and having an integrally mounted addressabla module that monitors and HM/MCP/GLASS + Local Bock
1.9 Nos. 17
reports contact Box
status.

Supply,Installation,Testing & Commissioning of Addressable weather proof Break Glass / Manual Call
Point having Rotary, decimal addressing system and having an integrally mounted addressabla module that HM/MCP/GLASS + Local Bock
1.10 Nos. 3
monitors and Box + Weatherproof box
reports contact status.
Addressable Manual Dual Stage Pull Station type Call Points complete with
1.11 Nos. RO
housing, LED indicator, test key etc.
Supply, Installation, Testing & Commissioning of ceiling mounted loop powered Horn / Strobe rated
1.12 Nos. RO
at 82 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication.
Supply, Installation, Testing & Commissioning of wall mounted fire alarm
1.13 Nos. 1 WSO-PR-N05 + MI/B501AP/IV
sounder rated at 82 dBA @ 3m for Audible annunciation.
Supply, Installation, Testing & Commissioning of fire alarm sounder with flasher rated at 82 dBA @ 3m for
1.14 Nos. 12 WSS-PR-N05 + MI/B501AP/IV
Audible annunciation and 75cd flashing at 1 Hz for visual indication.
Supply, Installation, Testing & Commissioning of weather proof fire alarm sounder with flasher rated at 82
WSS-PR-N05 + MI/B501AP/IV
1.15 dBA @ 3m for Audible annunciation and 75cd Nos. 4
+ Weatherproof box
flashing at 1 Hz for visual indication.
1.16 Addressable Fault isolator/Short circuit isolator module Nos. 12 MI/DISO
Addressable Monitor Module complete with status indicator LED test switch, junction box, for third party
1.17 Nos. 10 MI/DMMI
devices such as gas detectors, flow switches and tamper switches.
Single Input Monitor Module, requires M220E/SMB or surface mounting or M200E-Din for mounting to DIN rails.
Nos. 16 MI/DMMI
Note :- Use for fire fighters telephone system.
Addressable Control Module complete with status indicator LED and junction
1.18 Nos. 20 MI/DCMO
box, for AHUs, Ventilation / Pressurisation Fans and sounder.
Supplying, installing, testing and commissioning of 2c x 1.5 sq. mm, PVC insulated FRLS Armoured
1.19 copper cables confirming to IS standards and Mtr 2800
specifications.
Supplying, installing, testing and commissioning approved make 20 mm dia.MS flexible conduits on ceiling / wall
1.20 Nos. 200
/ floor etc. complete with accessories like, Junction boxes, Collars, Bends etc.
Supplying, installing, testing and commissioning 40 strand twin core PVC insulated copper wires,
1.24 Confirming to IS 1554, as per specification and to be laid in PVC conduit.The quoted rate shall include Nos. RO
supply and laying of 19mm dia FRLS PVC conduit with necessary supports.

TOTAL FOR FIRE DETECTION

Rate
Sr.No DESCRIPTION UNIT QTY Rate per unit Amount HONEYWELL MAKE Model
Supply Installation
No
1 PUBLIC ADDRESS AND VOICE ALARM SYSTEM
Supply, Installation, Testing and Commissioning of Master Controller Unit for supporting six zones used in
conjuction as per EN60849 standard inclusive of
1.1 Nos 1 HCU-2000-E
basic Software for management Note:- Main control unit HCU-2000 (RoHS), With
the built-in 500W Class-D amplifier, the single controller can work as an 8-zone VA/PA system

1.2 Supply, Installation, Testing and Commissioning of Slave Controller Unit for supporting six zones. Nos RO

Supply, Installation, Testing and Commissioning of Additional Amplifier - 480 Watts, operating voltage 100-
1.3 230VAC or 24VDC, 19" rack mountable form factor for connectivity of speakers. Note :- We have qoute 500W Nos 1 HN-A500I/
Digital Power amplifier.
Supply, Installation, Testing and Commissioning of Additional Amplifier - 240 Watts, operating voltage 100-
1.4 Nos RO
230VAC or 24VDC, 19" rack mountable form factor for connectivity of speakers.
Supply, Installation, Testing and Commissioning of Additional Amplifier - 120 Watts, operating voltage 100-
1.5 230VAC or 24VDC, 19" rack mountable form Nos 0
factor for connectivity of speakers.

Supply Installation, Testing & Commissioning of Paging microphone with ON/OF switch with Zone
Selection suitable for 6 Zones Touchscreen optional or pushbutton console with power supply, RS485
connections, High-quality electret omnidirectional microphone, optional Back-lit touch pad, All
1.6 parameters needed for site operating can be programmed: zones assigned to the different buttons, name of No. 1 HMC-2000-E
zones, zone groups, priorities, access to different messages, levels adjustments, pre-call chime, press-to-
talk, music ON/OFF and music routing, built-in loudspeaker, password-protected access complete with all
necessary accessories.

19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD
player, FM sources, Amplifiers etc modules, shall have Lockable doors, with proper ventilated and Openable
1.7 No. 1 (9U Rack quoted - Valrack)
doors from all sides, with casters and with cooling fans as above complete with necessary mounting hardware
& accessories.

SITC of Call station keypad Call Station with built in numerical keypad supporting 6 zones,
gooseneck microphone with supervised electret microphone, pop shield and permanent monitoring,
1.8 Nos 1
integrated loudspeaker for system sounds.Call Station is supervised by system controller can be expanded by
connecting 5 additional extention keypads
Ceiling Mounted Speaker: Rated Power – 6 Watts, Rated Voltage: 100 volts, Effective frequency range :(80 Hz
1.9 Nos 92 HN-CL06/
to 16000 Hz). Speakers should be capable of being monitored.
Wall Mounted Speaker with Strobe: Rated Power – 6 Watts, Rated Voltage: 100 volts, Effective frequency
1.10 Nos RO
range :(80 Hz to 16000 Hz). Speakers should be capable of being monitored.
Wall Mounted Speaker: Rated Power – 6 Watts, Rated Voltage: 100 volts, Effective frequency range :(80 Hz to
1.11 Nos 22 HN-WM06/
16000 Hz). Speakers should be capable of being monitored.
Wall Mounted Speaker: Rated Power – 12 Watts, Rated Voltage: 100 volts, Effective frequency range :(80 Hz to
1.12 Nos RO
16000 Hz). Speakers should be capable of being monitored.
1.13 SITC External background music source & accessories- DVD/Tuner/MP3 Nos 1 Philips
Supply, Installation, testing & Commissioning of Cables for connecting speakers: Supplying, installing, testing and
commissioning of 2c x 1.5 sq. mm, PVC insulated FRLS Armoured, annealed tinned copper cables, type ST2 FRLS
1.14 Mtr 847 Polycab
confirming to IS standards and specifications.The cable shall be fixed on the soffit slab with 3 nos of heavy duty clips
for every 1 meter of the running cable length.
Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/recess including
1.15 mtr 200 not required in Armoured cable
cutting the wall and making good the same in case of recessed conduit as required

TOTAL FOR PA System

Rate
Sr.No DESCRIPTION UNIT QTY Rate per unit Amount
Supply Installation
1 Talkback SYSTEM Make - Firelite
1.21 Supplying, installing, testing and commissioning approved make Fire Telephone Jack Nos. 16 FPJ-F
Supplying, installing, testing and commissioning of Fire fighters telephone handsets with coil in a recessed
1.22 Nos. 1 FHS-F
mounted single storage cabinet.
1.25 FIRELITE, Fire Fighter Telephone System Nos. 1 ECC-FFT
Supply, Installation, testing & Commissioning of Cables for connecting speakers: Supplying, installing, testing and
commissioning of 2c x 1.5 sq. mm, PVC insulated FRLS Armoured, annealed tinned copper cables, type ST2 FRLS
1.24 Mtr 400 Polycab
confirming to IS standards and specifications.The cable shall be fixed on the soffit slab with 3 nos of heavy duty clips
for every 1 meter of the running cable length.

TOTAL FOR FIRE DETECTION ₹ 0.00

TOTAL AMOUNT

Terms & Condition :

1. Monthly running bills will be submitted as per work Executed.


2. Water and Electricity shall be provided on each floor free of cost by the client.
3. CGST@ 9% & SGST@ 9% / IGST@ 18% will be applicable on actual bill amount as per Govt. rule
4.These are preliminary rates and may vary based on actual approved design.
5.All rate are excluding GST
6.Rate List will be vailed up to 45 days .
7.15% Extra charges of outstation given by client if Labour food and travelling provided by contractor and labour staying provided by client
8.Storage facilities for all materials and all equipment's, light, Electricity power and water facility to be provided free of cost by client on site.
9.Measurement should be checked only once either by Client or by Architect within a week, and that will be Final
10.Electricalwork is not in our scope.
11.Licenseing charges in client scope.
Payment Terms:
1. 30% of the contract value as Mobilization Advance against PI.
2. 50% of the item rates on before delivery of materials at site.
3. 15% of the item rates against execution (RA Bill) of the works at site.
4. 5% on completion of the works.
5. Payment to be released within 7 days from Invoice submissions.

For AMA Design Solutions Pvt Ltd.

Authorized Signatory