E1005 Spec

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Avery Weigh-Tronix Technical Specification E1005

E1005
indicator
Description
General
This specification describes the
E1005 indicator, capable of
stand-alone operation, or of
integration into a larger system
via serial interface.

It is a microprocessor-based
industrial weighing system with up
to 100,000 displayed increments
for analysing, displaying, storing
and transmitting gross and net
weight information.

Up to four analogue load cells to


be connected with the indicator.
The E1005 can be matched to
almost any load cell system to
achieve optimum accuracy,
stability and repeatability.

The indicator can control its


surrounding process using
configurable outputs.

Configurable Features
The E1005 features a keyboard
which allows any of the following
functions to be configured during ● Five points for linearity All these characteristics are
commissioning: correction to ensure maximum stored in non-volatile memory so
accuracy that once the ideal parameters for
● Sensitivity to weight signal any given weighing system are
● Tare availability established they can be retained
● Scale capacity with certainty for the future.
● Time and date
● Number of divisions and Once the scale is set up as
● User-definable serial output required, a calibration report can
increment size
strings be printed showing weighing
details (useful for the installation
● Weighing Unit engineer). This allows the state of
● Grand total information
the system to be monitored.
● Zero / back balance
● Scale ID number
One PLU is provided for simple
● Decimal marker type - point or totalising and storage of user-
comma ● I/O operation
defined parameters.

● Position of decimal marker

● Filtering parameters

1
E1005 Avery Weigh-Tronix Technical Specification

Applications Load Cell Input Filter


Parts Counting Maximum Load Cells if 350Ω Selectable averaging: fast,
Simple counting mode. Four medium and slow.

Static Checkweighing Connection of Input Balance/Zero


Set limits, manually or by sample Via 9-way, D-type connector.
mode.
Setting
Excitation Keyboard push button.
Peak Hold Direct current
Records maximum weight
Size of Balance Range
measured. Clear button resets Voltage Normally 10%, up to 100%.
memory. 5 V dc
Zero Indication
Totalising Current Within 2% of maximum capacity.
Single totals channel. Up to 115 mA
Under Range Indication
Remote Display Mode Remote Sense Displays “_ _ _ _ _ _”
Connect to, or use as a remote Obtained from excitation, or
display. linked directly to reference input Zero Tracking
connectors at the indicator Configurable.
Specification
uV/ per Division Motion Detection
0.5 Configurable.
Electrical
Resolution
Display Non- Approved 100,000. Range/Span
Approved 6,000.
Type Range of Adjustment
LCD, reflective, 20 mm 0 - 100,000 divisions
Displays up to seven digits Calibration
Over Range Indication
Decimal Points Full digital multi-point (five point) Displays “— — — — — —”
Configurable to any of six calibration.
positions.
Theoretical calibration possible if Tares
Units Displayed parameters known.
kg, lb, custom. Push-Button (Semi Auto) Tare
Increment Multiplier Push-button operated, semi-
Annunciators 1, 2, 5, 10, 20, 50 automatic, with selectable
Balance (Gross Zero) negative weight display.
Motion Cumulative taring is possible.
Gross Analogue to Digital
Tare Convertor Initialisation and Operation
Net When the item to tare on is
lb, kg, custom Display Update Rate applied, press the ‘Tare’ push-
Under/Target/Over 1, 2, 5, 10 per second. button.
Print
Three Trip Outputs Indication
A to D Rate
Peak
50 per second. ‘Net’ annunciator is illuminated.
Battery Status

Keypad A to D Type
Delta Sigma.
7 keys, addressing:
Function Key
Dedicated Function Keys:
Zero, Tare, Select, Print, Units,
On/Off

2
Avery Weigh-Tronix Technical Specification E1005

Trips Electrical Power Input Mounting Options


The indicator has three internal Voltage The indicator will desk, wall or
non-sequencing trips as standard, 100 VAC - 230 VAC nominal, pole mount.
logic level rated. 50/60 Hz.
Pole mounting requires optional
Using the external TIU3, these Tolerance adapter.
will switch mains voltage Voltage -15 to +10%
(240 V 2 A). Internal inputs are Frequency ±10%. Performance
rated at logic levels.
Power Consumption
Internal Resolution
The trips can be set to activate an 20 VA maximum when used with
16,777,216
output based on a given weight full configuration of load cells
target.
Self Diagnostics
Cable length
Display
All configuration information is 2 m.
Keys
retained when power is off.
A2D
Power Supply
Serial Test (1)
Product Look Ups External linear plug type.
Internal I/O
(PLUs) & Totals Battery Operation
External I/O
Internal battery provides on a
Information Stored per PLU single charge: Approvals
Grand Totals.
● 25 hours on single load cell. All data relating to the
Maximum Capacity of PLU ● 15 hours on four load cells. performance of the machine
9,999,999. meets and exceeds requirements
Isolation Protection of EN 45501:1992 European
Real Time Clock None. Mains earth lead must be Approval (‘E’ Approval) Accuracy
connected to safety earth. Class III Machines and
The E1005 is fitted with a real OIML 76-1. The type approval
time clock which allows the user Environment certificate numbers being:
to display and print the time and
date. This clock is battery-backed EU -UK2723
Resistance to Dirt and Moisture
and will remain functional in the South Africa -
Protected to IP54, in moulded
absence of mains power. New Zealand -
ABS enclosure.
Australia -
OIML -R76/1992-GB1-
Communications Electrical Disturbance
04.09
Immune to electrical disturbance,
NTEP -04-029
Serial Interface including RFI as detailed in
One bi-directional asynchronous EN 45501:1992.
serial interface (RS232/485/422
Factory Options
and RS232/20mA current loop) as Operating Temperature
standard. -10° C to + 40° C Choice of mains power connector:
UK, Euro, Australian, South
For comms to PC or printer, Service Temperature African, American.
requires standard straight-through -10° C to + 55° C
cable.
Storage Temperature
-40° C to +70° C

Finish
Enclosed in moulded ABS plastic
case.

3
E1005 Avery Weigh-Tronix Technical Specification

Accessories Dimensions
1. Trips Interface Unit (TIU3)
Provides three external mains 248
rated outputs in place of three
internal logic level I/O included as 229 178
standard.
E10100E00000000

2. 300 mm Pole
Stainless steel mounting pole with
top mounting plate for indicator. 165
E11100U00000000 222

3. 1000 mm Pole
Stainless steel mounting pole with
top mounting plate for indicator.
E11100V00000000

4. Interface Leads for Platform


to Indicator
See price list.

Weight
2.1 kg

Shipping Specification All dimensions in millimetres

Net
2.1 kg

Gross
3.6 kg

Measurement
375 mm x 280 mm x 235 mm

Harmonised Commodity Code


842390 00 0.

© Avery Berkel Limited 2004. All rights reserved. This publication is issued to provide outline information only which, unless agreed by Avery Berkel Limited in writing, may not be regarded as a representation relating
to the products or services concerned. Avery Berkel Limited reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service.

Your local distributor:

Foundry Lane, Smethwick,


E mail: info@awtxglobal.com West Midlands, England B66 2LP.
Internet: http://www.averyweigh-tronix.com Tel: +44 (0)870 90 34343 Fax: +44 (0)121-224 8183

Produced by Avery Weigh-Tronix Publicity Department E1005/12.04/Issue 6


4

You might also like