CPC - Bridging The Connectivity Gap Between Traditional Sensors and Single
CPC - Bridging The Connectivity Gap Between Traditional Sensors and Single
cpcworldwide.com
Page 2
calibration, or probe maintenance). measurement range and could be industry for robustness, reliability,
However, the technology of SU reused, leading to lower long-term and accuracy and to allow their use
sensors is still evolving and, as a operating costs. Traditional sensors across the whole aspect of SUT.
result, many drug manufacturers do face their own shortcomings, Secondly, for those manufacturers
still rely on the stability, reliability, though. When used in a single-use who use traditional sensors in an
and reusability of traditional probes system, traditional sensors must be SUS, the universal availability of
in an SUS. SU probes have shown aseptically inserted in a way that a reliable, genderless, SU aseptic
their limitations when used in longer prevents leakage but maintains connectors that allows the easy and
manufacturing operations, such as sterility. The assembly required to intuitive connection of the sensor
in perfusion/continuous cell cultures. do so must be adaptable to allow the to the SUS is critical to give the
There is also a risk of an “out-of-the- use of probes of varying lengths. An manufacturer the confidence that
bag failure,” where SU probes fail autoclavable probe sheath or bellows their sensors are secure, do not leak,
and the end user needs a redundant fits around the sensor to maintain and function as designed.
probe setup. In these cases, sterility after autoclaving. A single-
conventional sensors serve as backup use aseptic connector sits on one An SUS needs secure, reliable,
in case the primary SU sensors fail. end of the probe sheath/bellows and leak-free connections between
a probe adapter on the other where various components and processes;
SU sensors do not always cover the the conventional sensor screws into SU connectors can be the first and
required measurement range with place. Incorrect assembly of the last line of defense in an SUS. Even
just one sensor, so two or more SU probe system can pose considerable using the best bag, filter and tubing
sensors must be used to measure will prove futile without a reliable
the normal range of operations in and robust connector. That is why
a biological reaction. In addition, it is critical to select a connector
SU sensors are typically set at the that is easy to use, robust, and does
factory and cannot be calibrated in not require additional hardware
line prior to use. SU sensors are then to assemble. Some connectors
incorporated into an SUS, which is are not easy to use because they
then sterilized using gamma radiation. require many assembly steps to
Exposure to gamma radiation can make the final connection; the
impact the accuracy of the sensor, Figure 3 more steps there are for assembly,
Traditional aseptic connector/probe assembly
which affects the accuracy of the the higher the chance an operator
calibration data and the measurement will make an error. If the connector
during runs. If an SUS incorporating requires hardware not integral to the
SU sensors is manufactured in connector to secure the connection
January and gamma radiated in (e.g., tri-clover clamps), operators
February but not used until months can misplace or forget to install the
later, the system must be used added components.
knowing that sensor recalibration
is not possible. Nevertheless, there Figure 4 The sealing mechanism of the
may be considerable uncertainty CPC AseptiQuik connector/probe assembly connector must be secure and
about its accuracy. Another drawback robust. Small, thin O-rings can either
of single-use probes is that they roll out of the connector or roll into
risks to product loss, the sterility of a the flow path when pulling tabs. Some
sometimes shorten the expiration
product, and measurement accuracy. connectors can leak media outside
date of a single-use bag, which can
cause bags to be wasted if they of the connector because the weight
SINGLE-USE CONNECTORS AND CONVENTIONAL
cannot be used before the expiration of the probe distorts the connector
PROBE INSERTION
date. This can result in thousands of seal, breaking sterility, and allowing
dollars being thrown away. As the industry continues to evolve media/buffer to leak outside the
and benefit from the advantages connector (known as side-load). CPC
Conversely, the historical accuracy offered by SUT, there are two genderless connectors have larger,
of traditional sensors, backed by aspects of sensor technology that stronger gaskets that were designed
decades of data is a trusted tool are important to highlight. Firstly, not to roll out with the membrane pull
for measuring critical process SU sensors have to evolve further to and are more resistant to side-load
parameters. They also have a wider meet the increasing demands of the than traditional aseptic connectors.