INSTRUCTION MANUAL
OF
SERIES LIQUID COOLERS
2 INSTALLATION 6 TROUBLESHOOTING
1. 1 Applications
Environment temp.(℃)
widely applied for CNC aggregate
machining centers, various
machining equipment, such as high
precision lathes, grinding machines,
Temp. range
sawing machines, etc., and can be applicable
applied for hydraulic machineries
and special machineries as well.
1.2 Applicable temperature range
The series liquid coolers are
designed to operate under a temperature Inlet oil temp.(℃)
range given in fig.1, and can’t be used ig.1 Applicable temp range for the Oil Cooler
under conditions where the temperature is
out of the given range. The environment temperature in this manual means room temperature.
1.3 Applicable liquids
The series liquid coolers are only applicable for cooling liquid, hydraulic liquid, grinding liquid,
lubricating liquid and cutting liquid, and are not applicable for following liquids:
a. Water and water soluble liquids (except LO/W-C type);
b. Flammable hydraulic liquid;
c. Fuels, such as gasoline, etc.
d. Liquids of medicines or foods;
e. Any kinds of poisonous or corrosive liquids.
1.4 Notes on safety
1.4.1 Please do cut off the power during routine service, maintenance and examination.
1.4.2 When the cooler needs to be welded,
a. Please remove the cooling system from the main body and drain the liquid completely from
the cooler.
b. Please conduct repairing in a well ventilated place where there is no danger of fire and the
discharge of refrigerant will not affect the surrounding persons.
c. Welding process should observe relevant safety regulations and provisions, and care should be
taken so as to prevent other parts or components from being burnt.
d. Welding should be conducted by personnel from the manufacturer or by qualified special
professionals.
2 Installation
2.1 Moving
During the moving of the unit, care should be taken to prevent it from being damaged due to
impact from external force or excessive bumping, and prevent it from being slant and upside down.
For above reasons, it is recommended to store the original packing. During the lifting, the center of
gravity should be controlled carefully.
2.2 Environment requirement for the place of installation
2.2.1 The cooling unit should be horizontally installed in a well ventilated, dry place and far from
dust and liquid fog. The air inlet and outlet ports should be at least 1m from the walls and other
objects, and necessary service clearance should be kept.
2.2.2 There should be no corrosive, flammable and explosive gas around the unit; and near the
installation spot, there should be no high temperature heating source and other heating objects. Besides,
2.2.3 The installation spot should be decided by the customers according to type and model of the
unit selected. The structure of the installation spot should be strong enough to endure the weight of the
Machanical Machanical
apparatus apparatus
LIQUID COOLER LIQUID COOLER
(bad) (good)
Fig.2 Pipe connection of liquid cooler and machanical apparatus
2.6 Power supply connections
Power supply connecting should be conducted according to the electrical connection diagram and in
observance of relevant electrical regulations and specifications.
2.6.1 Power supply and the fuses should conform to requirements and specifications of the instruction
manual and of the product nameplate. Operation voltage fluctuation of ±10% is permissible.
a. For model LO/W(R)-15~LO/W(R)35and LO/W-C series coolers, 3-phase 5-line power supply
system (3N~380V 50Hz) with neutral line (zero line ) shall be adopted. If there is no neutral line on
the power board and it is needed to use a grounding line instead, set an exclusive line as grounding
line, the resistance of which shall be smaller than 4Ω and the section area of which shall be greater
than 6 mm2, and in this case, the leaking protection switch shouldn’t be used in the circuit.
b. For model LO/W(R)-50~LO/W(R)-600 series coolers, 3-phase 4-line power supply system (3P~
50Hz /380V) shall be adopted, and the grounding line should be well earthed.
c. For model LO/W(R)-15~LO/W(R)35 and LO/W-C series coolers, if 3-phase 5-line power supply
system (3N~380V 50Hz) is to be adopted, remove the covering plate of the cooler in advance, find
the connection terminal row, remove the jump between terminals marked “PE” an “N” on the rows.
2.6.2 The section area of power supply lines shall meet the requirement of the electrical diagram. The
momentary starting current of the compressor is 5~10 times of the rated operating current. The
power supply shall meet the current requirements; otherwise, the liquid cooler will not start
normally.
2.6.3 The power supply circuit shall be equipped with an air-switch or breaker (fuse) independently, the
specifications of which shall match the current value on the nameplate.
2.6.4 It is not allowed to discretionally change the electrical connections inside the control cabinet, and it
is forbidden to close the A.C. contactors coercively.
3 Panel operation
3.1 Panel functions and operation
电源 液泵 故障 电源 制热 故障
POWER COMP PUMP ALARM POWER COMP HEAT ALARM
设置 向上 向下 启动/停止 设置 向上 向下 启动/停止
SET UP DOWN ON/OFF SET UP DOWN ON/OFF
【Note:The left numeric display indicates the liquid temperature (press <UP> button to display the
ambient temperature value); while the right one indicates the target temperature ( the SET
TEMPERATURE in thermostatic mode or a value of the ambient temperature plus room temperature
co-adjustment temperature difference in co-adjustment mode).
3.3 Quick modification of the set temperature
On primary interface, press <SET> button for 3 seconds to enter the interface for setting control
temperature/room temperature co-adjustment difference, the procedures are given in the following
diagrams;
Note: If there is no other operation on the setting interface for 5 seconds, the setting will be saved
automatically and exit.
Description of the parameters Factory default value Setting range
3.4 Press down <UP> and <DOWN> simultaneously to check the value of amperage, proceed as follows:
[Note]:Query current value when the function of compressor or pump current is enabled.
3.5Check/reset from trouble
When any trouble is detected, for temperature-probe absent trouble, the trouble code and the
temperature value will be displayed alternatively; while for trouble with the temperature probe still working,
the trouble code will be displayed alternatively. The controller will reset automatically when trouble is
eliminated.
3.6Control logic
3.6.1 fixed temperature mode
Table 1
Cooling control conditions Heating control conditions (dual-system)
[note] : RT1 -- liquid temperature measurement sensor TS -- user set value (room temperature and
uniform temperature difference) RT3 -- environmental temperature measurement sensor
[attention] : every time the compressor goes through the open-> stop action, the next time it starts again,
it needs to go through a time delay of 3min (protection against frequent compressor startup).
3.7 Passive contactors
The electrical control system features a function of outputting by a group of passive contactors, which
comprises the closing contactors of the relays. When the liquid cooler works normally, the output
contactors are engaged; and when the liquid cooler
Oil cooler
is not electrified or is abnormal, the output passive contactor User I/O
contactors will be disengaged. Whether the RC filter
(1) Causes and solutions for malfunction with code F1/F2 displayed
(2) Causes and solutions for malfunction with code F3/F4 displayed
(3) Causes and solutions for malfunction with code E02 displayed
Causes Compressor current overload, contactor KM2 circuit breaker QF2/FR2 trip
※ Check voltage of the power supply;
※ Check to see if the condensing fan works and if the revolving direction is
correct;
Checking
※ Check the air filter;
procedures
※ Check to see if the wind inlet and outlet of the cooler are expedite, and if
the environment temperature is too high;
※ Check to see if the heat /Wading of the equipment is excessive.
Solutions ※ Adopt a power supply connection system and external power supply wires
which meet the specifications;
※ Apply the specified power supply voltage;
※ Adjust the revolving direction of the fan;
※ Clean up the air filter;
※ Improve operating environment conditions;
※ Choose a suitable cooling system compatible with heat loading;
※ after troubleshooting, open the front cover plate (or top cover plate) of the
cooling unit, press the green button under QF2/FR2 to reset QF2/FR2.
(4) Causes and solutions for malfunction with code E03 displayed
The pressure in the refrigeration circuit is higher than the specified value, and
Causes
the high pressure protector jumps away
※ Check voltage of the power supply;
※ Check to see if the air filter is blocked;
Checking
※ Check the revolving direction of condensing fan;
procedures
※ Check to see if the environment temperature is too high or too low and if he
wind inlet and outlet of the cooler is expedite;
※ Adopt a power supply system and power voltage which meet the
specifications;
※ Clean up the air filter;
Solutions ※ Adjust the revolving direction of the fan;
※ Improve operating environment conditions of the liquid cooler;
If the high/low pressure protector trips frequently, please contact the
manufacturer.
(5) Causes and solutions for malfunction with code E04 displayed
The phase order of the power supply is not consistent with the specified phase
Causes
order of the liquid cooler.
※ Check the three-phase order of the power supply;
Checking ※ Check to see if the three-phase power supply lacks a phase;
procedures ※ Check the three-phase power supply to see if its voltage is the specified
value.
※ Exchange the positions of any two lines of three-phase power supply;
Solutions
※ Apply the specified power voltage.
(6) Causes and solutions for malfunction with code E05 displayed
(7) Causes and solutions for malfunction with code E06 displayed
The pressure in the refrigeration circuit is lower than the specified value,
Causes
and the low-voltage protector jumps off
※ check the liquid level of the liquid tank and whether the liquid pipeline
is unblocked;
Checking procedure ※ check whether there is any leakage in the cooling system of the cooling
unit;
※ check air path
※ add liquid or dredge liquid path to liquid tank;
※ repair and supplement fluorine when fluorine leakage occurs in
Solutions refrigeration system.
If frequent high and low voltage protector off phenomenon, please contact
the manufacturer
(8) Causes and solutions for malfunction with code E07 displayed
Causes Liquid level in liquid tank is below the specified lower limit
Checking procedures ※ Check the liquid level in the liquid tank;
Solutions ※ Keep the liquid level above the specified lower-limit ;
Causes The liquid temperature is higher than the set alarm temperature
Checking ※ check whether the liquid temperature has reached the set overtemperature
procedures alarm temperature before the cooling unit works;
※ check whether the cooling unit works normally;
※ check whether the air filter, ambient temperature and ventilation conditions
are normal;
※ check whether the liquid temperature sensor RT1 is normal;
※ check whether the load capacity of the cooling machine is less than the
actual heat load.
※ enables the cooling unit to operate simultaneously with the mechanical
equipment generating heat source;
※ if the cooling unit does not work normally, it shall be handled with
reference to the above clauses; If it is working normally, check whether its
working current is within the rated range;
※ Clean air filter, improve environmental conditions and maintain good
Solutions
ventilation around;
※ determine whether the liquid temperature displayed by PV is significantly
different from the actual liquid temperature, and judge whether the liquid
temperature sensor works normally.
※ select the model with load capacity matching the actual thermal load;
※ contact the manufacturer if necessary.
(11) Causes and solutions for displaying trouble codes E11/E12
Cause of trouble To high or too low operating amperage of the compressor
※ Check the voltage of the power supply;
※ Check if the condensation fans works normally and if its direction is
correct;
Check procedures ※ Check the air filtering screen;
※ Check if the cooling unit’s inlet and outlet air ports are unblocked, if
the ambient temperature is too high;
※ Check if the heat load of the equipment is too excessive
※ Apply the specified power system and external power cables with
specified wire gauges;
※ Apply the specified power voltage ;
Solutions ※ Adjust the direction of the fan
※ Clean the air filtering screen;
※ Improve the ambient condition for operation
※ Select a unit appropriate for the heat load.
(12)Causes and solutions for displaying trouble codes E13/E14
Cause of trouble Too high or too low amperage through the liquid pump’s motor
※ Check the voltage of the power supply;
Check procedures
※ Check if the liquid circulation is blocked.
※ Apply the specified power voltage
Solutions
※ Clear the liquid circulation
[note 1] : the above faults include other faults except "E05, E13, E14, E17 and E18". If the machine is
running before the failure, the machine will automatically run after the failure is reset.
[note 2] : the above faults, except "E05, E06, E15, E16, E17 and E18" faults, will alarm after 8
seconds.
[note 3] : if there are multiple faults at the same time, each fault sequence number will be displayed in
turn (if there is no fault of temperature probe, each fault sequence number and temperature value will
be displayed in turn).
(3)The set temperature isn't reached, but the compressor stops cooling
(4)The cooling conditions are met,but the compressor does not work
If the following incidents experienced, stop the liquid cooler immediately, and consult the
manufacturer for solutions:
① Fuses or breakers break frequently, or the failure indicator alarms frequently;
② The compressor starts and stops repeatedly;
③ The compressor works normally, but the liquid pump or the fan doesn’t work simultaneously;
④ The liquid pump or the fan works normally, but the compressor doesn’t work after a long
time.
⑤ There is abnormal sound during the operating of the liquid cooler.
7 Warranty
7.1 Our company, based on the invoice, provides free service or replacement for the complete unit
for one year (according to the date on the invoice) in case the unit doesn’t work normally
because of manufacturing defects on condition that the user observes the instruction given in
this manual.
7.2 Damages caused by not observing the instruction given in this manual or due to inappropriate
external conditions (e.g. the power supply voltage fluctuation exceeds the permitted range, the
environment temperature is too high, etc.) are not covered by the warranty.
7.3 The company is not responsible for free service for products which the user has disassembled,
modified, or repaired by itself without informing the manufacturer.
7.4 Damages caused due to human faults, such as impact happened during the installation,
transportation and operation, are not covered by free service and free replacement warranty.
7.5 Related expenses (including travel cost) for services and repairs not covered by the warranty
or after the expiry date of the warranty shall be paid by the customer.
Appendix A YL-7K Control board
Alarm
Liquid temp.
AC220V Environment temp.
Pump
Compressor
COM
Heater
Low/Oil pressure swicth
Compressor high pressure
Compressor Overload
Liquid Level switch
Flow switch
Remote switch
Three-phase power
Power supply AC10V
ir out
ir out
ir in
Air out ir out ir in
Power switch
Control panel Air filter
Control panel
Power supply
Air filter
lead Power supply
Air filter
lead
Cooling coil
Cooling coil
EVAPORATOR
FAN
CONDENSOR
LOW-PRESSURE HIGH-PRESSURE
PROTECTOR PROTECTOR
LIQUID INLET P< P>
COMPRESSOR
COOLING
EXPANSION VALVE FILTER DRIER
HEATING
LIQUID OUTLET
EVAPORATOR
CONDENSER
FAN
4-WAY
VALVE
GAS/LIQUID COMPRESSOR
SEPARATOR
MODEL LO-15PTB
Total Current(A) 4
Controlled temperature For fixed temperature type: 15~45℃/Type. For differential temperature
rang control type: room-temperature ±9℃. Control precision: ±1℃
composers
Refrigerant t R22
F
PACKAGE LIST
MODEL NUMBER: L -
MANUFACTURING NUMBER:
This product has been passed through the test and factory inspection,
and all the performance data meet the requirement of the technical
specification & regulation.
Laber warrants its products for one year from the date of delivery.
During the warranty period, if a product malfunctions in normal use,
the company will repair the product without any charge. For a product
which has expired the warranty period, reasonable fee is needed.
Homepage: www.bjlaber.com
Postcode: 721006