Prepared By: Yoseph Bete ID: 010/12 Submitted To: Yohannes.T


First Space Type: Office

Specific Type: Open Office

Shape: Rectangular

Standard Open Office Floor-plan.

Division of space using modular desks. Various office spaces in open-plan office
system: a) manager, with small meeting or conference room; b) assistant or
departmental head; c) secretary, receptionist; d) senior clerk dealing with public;
e) work rooms (working groups)

Sectional View of Open Office


Layout.

Standard Swivel
Chair Dimensions
Light Levels in Office Buildings

 LUX standard for any


office space is 400 – 500.
 Type of Lighting: Task
Light
 Bulb Type: Fluorescent
 Shape: Cylindrical

Light Cut Sheet

LUMILUX T8 | Tubular fluorescent lamps


26 mm, with G13 bases

Tube diameter 26 mm
Length with base excl. base 1500 mm
Lifespan
Service life 18000 h
Additional product data

Mercury content 3.0 mg


Appropriate disposal acc. to Yes
WEEE
Predecessor EAN 4050300
443362
Electrical data
Nominal current 0.67 A A
Photometrical data

Light color (designation) LUMILUX


Cool White
Rated LLMF at 2,000 h 0.96
Rated LLMF at 4,000 h 0.94
Rated LLMF at 6,000 h 0.93
Rated LLMF at 8,000 h 0.91
Rated LLMF at 12,000 h 0.91
Rated LLMF at 16,000 h 0.9
Rated LLMF at 20,000 h 0.89
Luminous flux 5200 lm

Second Space Type: Auditorium Hall

Shape: Rectangular

Auditorium theatre seating /desk


Standard Rectangular Auditorium Layout with 200 Seats
Lux Standard for Auditorium: 500-750

Type of Lighting: Auditoriums use combination of General/Ambient Light and Task light
because of the variable activities that this space hosts.

An Auditorium needs lighting which is adjustable and with integrated system that allows
it to transition from different modes/functions the space is hosting so it is preferable to
select a light/ bulb type altogether as a system provided basically fo auditorium purpose.

Light Cut Sheet

- In this case a selection of a brand that provides the full system.

itc lighting system with Conference Lighting, adjustable system, Conference


mode switch, and short response time.
Meeting Mode:

High-brightness is required plus it’s ultra-quiet for meeting purpose, no strobe light and no
glare.

Performance Mode:

This makes the stage beautiful while increasing the interaction of the main and auxiliary lighting
and rendering the atmosphere.

Types of Stage Lighting:

A. Moving Head B. Effect Light: C. Film Light: the


Light: the beam effect lights are film and television
lamp is a type of
light is to focus mainly used to
lamp used for lighting
the light source render the and achieving a
on a focus so colors of the certain light effect in
that the light stage, to stage performances
and film and
source is more enhance the television shooting.
concentrated atmosphere.
and emitted to
form a light
beam.
Conference Lighting:

Through the imported LED lamp bead materials, the meeting lighting effect of the lecture hall
is clear, no ghosting, and no glare, so that participants' meeting fatigue is reduced Enjoy the
meeting.

Conference Mode Switch:

Support the call of light mode. There is a high-performance console in the background, which
rapidly calls different meeting modes of the auditorium and adapts to the lighting effect of
different meetings of the auditorium by using different light scenes.

Adjustable System:

The power consumption caused of stage lighting can be saved by adjusting the lighting scene
procedure according to the quantity of people in the report hall and the scale of the meeting.

Short Response Time:

The lighting on time of LED stage light is in milliseconds, which fully meets the use of
emergency meeting in the reporting hall. When switching the light mode, the response
degree of the light body can also be switched rapidly.
Third Space Type: Vehicle Gallery/ Showroom

Shape: Rectangular

Standard Lux: 500-700

Standard Space Layout and Dimensions


Type of Lighting: Accent Lighting

Type of Bulb: Rectangular LED

-When designing and placing these LED lightings they can be placed on and
besides the vehicles to highlight their appearances and attract the eyes of
customers.

- So the LED lights I have chosen can be maneuvered easily and placed
anywhere in the showroom.
Light Cut Sheet

Agilent 2 mm x 5 mm
Rectangular LED Lamps
Datasheet

Graph Showing Relative luminous intensity


vs. angular displacement.
Luminous Intensity Iv
(mcd) at 20 mA
Color Part Number Min. Typ. Max.
AlGaAs Red HLMP-S100 3.4 7.5 –
HER HLMP-S201
HLMP-S201-D00xx 2.1 3.5 –
HLMP-S201-E00xx 3.4 7.5 –
HLMP-S201-EF0xx 3.4 7.5 10.8
Orange HLMP-S400 2.1 3.5 –
HLMP-S401 3.4 7.5 –
Yellow HLMP-S301
HLMP-S301-B00xx 1.4 2.1 –
HLMP-S301-C00xx 2.2 4.0 –
HLMP-S301-CDBxx 2.2 4.0 7.2
Green HLMP-S501
HLMP-S501-C00xx 2.6 4.0 –
HLMP-S501-D00xx 4.2 8.0 –
HLMP-S501-DE0xx 4.2 8.0 13.4
Emerald Green[1] HLMP-S600-A00xx 1.0 3.0 –