Download as pdf or txt
Download as pdf or txt
You are on page 1of 3



Customer &DUGRQ,9 Project No. ,17 By 6:+


Project 006&)'-7 Tag ( Checked 6/6
*XOIRI9HQH]XHOD 'HF *
Revision

Location Date Revision


Service +RW/HDQ5LFK*O\FRO([FKDQJHU 5LFK&DVH 5HY%\ 6:+
1 Size: [ Type %(8 (Hor/Vert) +RUL]RQWDO Connected In
2 Surf/Unit  ft² Shells/Unit Surf/Shell  ft²
3 3(5)250$1&(2)21(81,7
4 Fluid Allocation Shell Side Tube Side
5 Fluid Name /HDQ*O\FRO 5LFK*O\FRO
6 Fluid Quantity, Total (lb/hr) [ [
7 Conditions At Inlet Outlet Inlet Outlet
8 Vapor Flow (lb/hr)   [ [
9 MW (lb/lbmol)    
10 Density (lb/ft³)    
11 Viscosity (cP)    
12 Therm Cond (Btu/hr-ft-F)    
13 Heat Capacity (Btu/lb-F)    
14 Liquid Flow (lb/hr) [ [ [ [
15 Density (lb/ft³)    
16 Viscosity (cP)    
17 Therm Cond (Btu/hr-ft-F)    
18 Heat Capacity (Btu/hr-F)    
19 Surface Tension (dyne/cm)    
20 Latent Heat (Btu/lb @ °F)
21 Temperature (°F)    
22 Pressure (psia)    
23 Velocity (ft/sec)  
24 Pressure Drop (Allow l Calc) (psi)    
25 Fouling Resistance (Min) (Btu/ft²-F)  
26 Heat Exchanged (MMBtu/hr) [ MTD (Corr) 
27 Transfer Rate, Service (Btu/hr-ft²-F)  Clean 
28 &216758&7,212)21(6+(// 6NHWFK %XQGOH1R]]OH2ULHQWDWLRQ
29 0DQXIDFWXUHU6KHOO 7XEH Shell Side Tube Side
30 Design Pressure (psig) )9 
31 Test Pressure (psig) 3HU&RGH 3HU&RGH
32 Design Temperature (Max) (°F)  
33 MDMT (°F)  
34 No. Passes per Shell  
35 Corrosion Allowance (in)  
36 Connections In (in) 5) 1RWH 5) 1RWH
37 Size & Out (in) 5) 1RWH  5) 1RWH
38 Rating Intermediate (in) 
39 Tube No. 8 OD  Thk(Min/Avg)  Length 
Pitch 
40 Tube Type 3ODLQ Material 6$
41 Shell 6$% ,'2' Shell Cover (Integ.) (Remov.)
42 Channel or Bonnet 6$% Channel Cover
43 Tubesheet - Stationary 6$1 Tubesheet-Floating
44 Floating Head Cover Impingement Protection
45 Baffles-cross 6$ KRUFXW Type 6LQJOHVHJ %Cut (Diam/Area)  Spacing: C/C  ,QOHW
46 Baffles-Long Seal Type
47 Supports-Tube U-Bend Type
48 Bypass Seal Arrangement SDLUVHDOVWULSV Tube-Tubesheet Joint ([SDQGHG JURRYHV
49 Expansion Joint Type
50 rV²-Inlet Nozzle  Bundle Entrance  Bundle Exit 
51 Gaskets-Shell Side Tube Side
52 -Floating Head
53 Code Requirements $60(6HFWLRQ9,,,'LY/DWHVW TEMA Class 5 National Board Registered <HV
54 Weight/Dry  Filled with Water  Bundle  lb
55 127(6
56 LVWKHPLQLPXPRXWVLGHGLDPHWHUIRUWXEHVXQOHVVRWKHUZLVHDSSURYHGE\&DUGRQ,99DOHUXV
57 7XEHZDOOWKLFNQHVVVKDOOEHVSHFLILHGLQDFFRUGDQFHZLWKWKHUHTXLUHPHQWVRI$16,$3,
58 'HVLJQSHUDWWDFKHG6FRSHRI6XSSO\&DUGRQ6SHFLILFDWLRQV9DOHUXV3DLQW6WDQGDUGDQG,QVSHFWLRQDQG7HVWLQJ5HTXLUHPHQWV
59 +RW,QVXODWLRQRQVKHOODQGRQFKDQQHOFRYHUV E\RWKHUV 
60 3URYLGHFSOJRQDOOVKHOORXWOHWQR]]OH
61 1R]]OHVDUHVL]HGLQDFFRUGDQFHZLWK&DUGRQ
VȡP9FULWHULD
62
63
This document is the property of Valerus Compression Services, L.P. This information is proprietary and shall not be disclosed outside your organization, nor shall it be duplicated, used or
disclosed for any purpose other than as permitted under written agreement with Valerus Compression Services, L.P. or its subsidiaries.
P&ID Sheet 59 INT143-30-800-E-3020-01-RG