Filter Line Density Color Map Baseline B Reject TDI Color Map TDI Loop Speed TDI Power Triplex Mode Color Invert

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

SPESIFIKASI - ADVANCED DUS-7000

TECHNICAL SPECIFICATIONS
ELECTRICAL POWER
Voltage : 100/220 V
Current : 3.15 Amps
Freguency : 50/60 Hz
ENVIRONMENTAL REQUIREMENTS
Temperature : +10 to +40 Degrees C
Relative Humidity : 30% to 75%
(Non-condensing)
Atmospheric Pressure : 700 to 1060 hPa
PROBE CONNECTORS
Active Connectors : 3 Connectors
APPLICATIONS
Abdominal/Cardiology/Obstetrical/Gynecological/
Musculoskeletal/Vascular/Urological/Small-Parts/
Pediatric/Anesthesia
SCANNING METHODS
Electronic Convex Sector
Electronic Linear
Electronic Phased Array Sector
Mechanic Volumetric
Color Doppler, CW, PW
SWEEP METHODS
Curved Probe : 70° or more
Phased Array Probe : 90° or more
Micro-Curved Probe : 193° or more
OPERATING MODES
B-MODE
Gain : 1-255 dB 1 dB /step (255 Steps) Full Range Adjust
Depth : 32.9 cm Max (Probe Dependent)
Zoom : Max. >=10, Show zoom X value
TGC : 8 Slide Controls
Inversion : Left/ Right/ Up/ Down
Mode : 2B & 4B
Compound Image : ON/OFF
Focus : Up to 12, focus span Adjustable
Frequency : 5 steps
Chroma : Max. 13 Selectable
U-Scan : Adjustable
Line Density : 3 Selections (High/Med/Low)
Dynamic Range : 20-280 dB (Probe Dependent)
GSC : 7 Steps Selectable, 0-255
SEC. WIDTH : B Image Lateral Position Adjust
Power : 1 to 100% Changeable
B Steer Mode
COLOR FLOW (CFM)/ TISSUE DOPPLER IMAGING
MODE (TDI)
Gain : 0-255- Adjustable
Frequency : 2,3,4,5,7 MHz
Frequency Range : 5 Steps
PRF (Speed Scale) : 1-20 KHz
Frame Rate : ≥50 Frames/ sec
Color Area Size and Position : Adjustable
Filter : Up to 750 Hz (Exam Dependent)
Line Density : 2 Kinds (Low and High)
Color Map : 11 Kinds (Probe Dependent)
Baseline : ±15 Steps
B Reject : 0-255
TDI Color Map : 1-4 Invertible
TDI Loop Speed : 1-4
TDI Power : 0-100% 10 Steps
Triplex Mode Use 2D Refresh, Display B, CFM and PW
:
Simultaneously
Color Invert : Finv Key to Invert Color Map
Speed Limit : 3cm/s – 68cm/s
M-MODE
Steer M/Anatomic M 3 Lines, Display Frame Rate, Allow Steer M to Store
:
in User Define Preset
Color M-Mode : Display Both Color Flow and M Mode
Video Invert : ON/OFF
Inversion : Up and Down
Sweep Speed : 2,4,6,8 Sec/Plane
Chroma : 5 Kinds Selectable
Display Format : H1/2, H1/4, V1/3, V1/2, V2/3, O1/4
Power : 30 to 100% Changeable
SPECTRAL DOPPLER
Pulsed Wave Doppler (PWD)
Continuous Wave Doppler (CWD)
Sample Volume Size PW Doppler 1-20 mm
Changeable in 1 mm Step, Display Doppler Sample
Volume Size
2D Refresh : ON/OFF
Video Invert : ON/OFF
Mode : 2B
Audio Volume : 0-100 Steps Adjustable
Filter : 50-1000Hz (PW and CW)
Angle : 0-80 Degrees
Auto Trace function In Real Time
Baseline Shift : Available Up To 17 Steps
Frequency : 5 Steps
PRF Adjustable : PW 1-20 KHz
CW 1-48 KHz
Max Velocity Range : PW 0.0004-40.9 m/s
CW 0.0013-49.1 m/s
Sweep Speed : 2,4,6,8 Sec/Plane
Power : 30 to 100% Changeable
Chroma : Max. 5 Kinds Adjustable
Dynamic Rage : 10 Steps Selectable
Display Format : H1/2, H1/4, V1/3, V1/2, V2/3 , O1/4
Steer Angle 5 Kinds (Linear Probe) Max. ±20 degrees, 0, ±16,
:
±20 Changeable
3D/4D IMAGING
3 Arbitrary Sections Simultaneously
Display Mode : Dual Display
Quad Display
Full Display 2D
Full Display 3D
Full Display 4D
Rotate : X/Y/Z
Move : L-R/ U-D
Trace Cut : On/Off
Render Mode : Vol, MaxIP, X-Ray
Auto Rotate : 45, 90,180,270,360° Adjust
Opacity : Offset 0-255 Adjustable
Slope 0-255 Adjustable
Z Scale : Adjustable
Z angle : 10-170° Adjustable
Color Map : 4 Kinds
Multi Slice : Ref A, Ref B
Slice Spacing : 0.5-2.0 Adjustable
Sweep Angle : 20-75 Degrees
Image Quality : High, Med, Low
4D Gain : Adjustable
Frame Rate : 5 Frames/Sec or more
INTEGRATED DATE MANAGEMENT SYSTEM
Hard Disk Memory Capacity : 320 G
Storage Media : USB Drive
STORAGE OF IMAGES AND CINE
Cine loop : 10000 Frames or more
Cine Loop Time : 60 Seconds or more (≥500 frames per Cine)
Real Time Single/Dual Static and Dynamic Image Storage
Archived Image Can Be Viewed on PC
Crop board Function : In Freeze Mode
Doppler Cine Sound Play Back Function
DICOM Network Communication
PHYSIOLOGICAL SIGNAL DISPLAY
ECG, Pulse Wave
ECG Lead-Three Lead System
ECG Gain : Adjustable
ECG Position : Adjustable
ECG Invert : On/Off
R-Trigger : On/Off
Trigger Delay : Adjustable
Frame Count : Adjustable
USER INTERFACE
OPERATOR KEYBOARD
Shortcuts Keyboard
Integrated Recording Keys For Remote Control of Peripheral Devices and DICOM Devices
8 TGC Pods
Integrated function Key
CHARACTER AND ICON
Character Input Area : ID, Name, DOB, Sex, Weight, Height, LMP
Body Mark : 52 Kinds
OPTIONAL PROBE
Phased Array Probe (Cardiology)
Linear Probe (Vascular, Small Part)
Curved Probe (Abdomen, OB/GYN)
Micro-curved Probe (Transvaginal)
Linear, Surgical (Surgery)
MEASUREMENTS
General Measurements
On color Mode B-Mode, M- Mode, 4D-Mode, On Spectral Doppler
Obstetrical/Gynecological Measurements B-Mode, PW-Mode
Cardiac Measurements B-Mode, M-Mode, PW-Mode
Vascular Measurements
Urological Measurements
Small Part Measurements
Orthopaedic Measurements
REPORT FUNCTIONS
Obstetrical/Gynecological Report
Cardiac Function Report (Revisability)
Vascular Report
Urological Report
Small Part Report
IMT Report

You might also like