One FD Fan Tripping
One FD Fan Tripping
5. OUTPUT: Restore and stabilize the Boiler when one FD fan trips
6. PROCEDURE:
6.1 Corresponding FD fan flow should be increased to maximum level i.e 185000 m3/hr, 35
amps being the full load current.
6.2 Id fan scoop adjusted in such way that furnace draft should be kept at -0.05kpa, normally
after tripping of one FD fan the furnace pressure reduces to -0.50Kpa
6.3 If boiler is operating with three mill operation then stop one mill immediately and take one
oil gun for flame support
6.4 Bring the Boiler load down to 162 tph to 170tph for preventing the overloading of the
remaining FD fan
6.5 According to boiler load maintain the o2 2to 3%
7. QUALITY
7.1. All the parameters, activities are maintained as per the manual.
7.2. Any deviation is recorded and corrective action is taken accordingly.