NOVA LBS Improve continuity and reliability of your network with the new three-phase load break switch NOVA LBS
To meet the growing challenges of quality and continuity in
distribution systems, the NOVA LBS automatic load break switch offers greater possibilities, allowing the automation of distribution through intelligent sectioning.
Features
• Eaton vacuum bottle technology, SF6 free
• Cycloaliphatic epoxy solid insulation poles • Spring-type actuator mechanism for 10,000 operations • 6 internal voltage sensors • 3 internal current sensors • Independent opening and closing handle • Painted aluminum mechanism housing (stainless steel option Know-how and field-proven characteristics available) of the Eaton NOVA Recloser family: • IP-54 protection degree (IP-65 option available) • SF6 free • 6 internal voltage sensors LN015 / 27 • Smart grid ready Rated voltage 15 / 27 kV Rated lightning impulse withstand voltage 125 kV Rated power-frequency withstand voltage Dry, one minute 60 kV Wet, ten seconds 50 kV Rated normal current 630 A Rated short-time withstand current 16 kA (3s) Rated peak withstand current 41,6 kA Rated line-charging breaking current 2A Rated cable-charging breaking current 20 A Mechanical endurance operations 10.000 Electrical endurance class E3 Mechanical endurance class M2 Mass (Weight) – Switch only 105 kg (231 lbs) Mass (Weight) – Switch and control 135 kg (298 lbs) A new control designed for switching applications
Features
• LCD operation interface in EN, ES and PT-BR
• Open, Close and Supervisory Off buttons, plus 4 additional configurable buttons • 32 status LEDs, 6 configurable • Communication: USB 2.0, Ethernet RJ-45 and RS-232 DB-9 • Protocols: DNP 3.0, IEC-60870-5-101 and IEC-60870-5-104 • Stand-alone or web-based software configuration • Local / remote modes • 16 DI / 8 DO programmable through logic operators or analog comparators • Programmable multilevel user access passwords • Sequence of Events Recorder (SOE) A new control developed especially for NOVA • Oscillography LBS. • Graphical curve editor • Lifetime monitoring Ready for smart grid applications, the new • Full range power supply control meets all current distribution • IP-65 painted stainless steel enclosure automation requirements allowing an increase in the number of fault isolation areas. Applications
• Interrupt and isolate under load condition
• Sectionalizer function • Opening and closing through voltage absence or presence • Switch sources for Self-Healing applications • Increase in the number of disconnections in the distribution lines at a reduced cost, interrupting the energy supply in smaller areas • Increase coordination possibilities • Fault supervision point • Measurement point: current, voltage, power, power factor, energy, frequency and measurement up to 15th harmonic of voltage and current
Monitored protections
• Time or curve based overcurrent alarm (phase, ground and