PRODUCT DATA SHEET

Sikadur®-55 LP IN
Low viscosity, moisture tolerant epoxy injection resin and crack sealer

DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikadur®-55 LP IN is a two part, low viscosity, moisture ▪ Solvent-free
insensitive injection liquid, based on high strength ▪ Suitable for both, dry and damp conditions
epoxy resin specifically formulated for dry or damp ▪ Usable at high temperatures
crack sealing. Suitable for use in hot and tropical cli- ▪ Shrinkage free hardening
matic conditions. Confirms to ASTM C881, Type II and ▪ High mechanical strengths
IV, Grade-1, Class F. ▪ High bond strength even in wet cracks
▪ Hard but not brittle
USES ▪ Low viscosity
▪ Injectable with single component pumps
▪ To repair cracks by injection in structural concrete in .
slabs, columns, beams, walls, foundations, etc.
▪ For surface treatment of cracks in interior and exteri-
or slabs.
▪ For roof slabs, parking lots and structures exposed to
pedestrian and vehicular traffic.

PRODUCT INFORMATION
Product declaration Confirms to ASTM C881, Type II and IV, Grade-1, Class F
Chemical base Epoxy resin
Packaging Small packaging:
Part A+B pre-batched 1 kg
Part A 0.8 kg container
Part B 0.2 kg container
Bulk packaging:
Part A+B pre-batched 62.5 kg
Part A 50 kg container
Part B 12.5 kg container

Shelf life 12 months from date of production


Storage conditions The product must be stored properly in unopened, undamaged and sealed
original packaging, in dry conditions at temperatures between +5 °C and
+40 °C.

Product Data Sheet


Sikadur®-55 LP IN
June 2022, Version 01.01
020204010010000024

1/3
Colour Part A+B mixed Clear pale yellow
Part A Colourless
Part B Pale yellow

Density ~1.08 kg/L (Part A+B mixed, +27 °C) (EN ISO 2811-1)

Viscosity ~250 mPa·s (at +30 °C)

TECHNICAL INFORMATION
Compressive strength ~70 N/mm2 (7 days, +30 °C) (ASTM D695)

Flexural strength ~50 N/mm2 (7 days, +30 °C) (EN 196-1)

Tensile strength ~50 N/mm2 (7 days, +30 °C) (ASTM D638)

Modulus of elasticity in tension ~2000 N/mm2 (7 days, +30 °C) (ISO 527-2)

Elongation at break ~1.9 % (ASTM D638)

Tensile adhesion strength Curing time Bond strength (ASTM C882)


2 d, moist cure ≥ 7 N/mm2
14 d, moist cure ≥ 10 N/mm2

Shrinkage Passes (ASTM C883)

Heat deflection temperature ≥ 50 °C (ASTM D648)

Water absorption ~0.6 % (24 h) (ASTM D570)

APPLICATION INFORMATION
Mixing ratio Part A : Part B = 4 : 1 (by weight)
Ambient air temperature +10 °C min. / +40 °C max.
Substrate temperature +10 °C min. / +40 °C max.
Substrate moisture content Sikadur®-55 LP IN is suitable for dry and moist condition. No standing wa-
ter.
Pot life > 60 min (100 g mass, +30 °C)

BASIS OF PRODUCT DATA SUBSTRATE PREPARATION


Concrete, mortar, stone should be thoroughly pre-
All technical data stated in this Product Data Sheet are pared by high pressure water jetting or mechanical
based on laboratory tests. Actual measured data may means such as grinding, chiselling etc. Cracks must be
vary due to circumstances beyond our control. cleaned to remove dust by using compressed air.
ECOLOGY, HEALTH AND SAFETY MIXING

User must read the most recent corresponding Safety Pre-batched packaging:
Data Sheets (SDS) before using any products. The SDS 1. Add all of Part B to Part A.
provides information and advice on the safe handling, 2. Mix with an electric mixer at slow speed (max. 250
storage and disposal of chemical products and con- rpm) for at least 3 minutes. Avoid entraining air.
tains physical, ecological, toxicological and other
safety-related data. Bulk packaging:
IMPORTANT
APPLICATION INSTRUCTIONS Part mixing is recommended.
1. Add both parts in the correct proportion into suit-
able clean and dry container, mix in the same way as
SUBSTRATE QUALITY for the pre-batched units.
Substrates must be sound, clean, free from oil and
grease, old coatings and surface treatments etc.

Product Data Sheet


Sikadur®-55 LP IN
June 2022, Version 01.01
020204010010000024

2/3
APPLICATION LEGAL NOTES
Impregnation of cracks in horizontal planes:
Saturate the crack by applying the product by paint The information, and, in particular, the recommenda-
brush or roller in several passes or by pouring tions relating to the application and end-use of Sika
between two "barriers" made with Sikaflex® sealant. products, are given in good faith based on Sika's cur-
The crack penetrating through structure must be rent knowledge and experience of the products when
sealed on the underside with Sikadur®-31 IN epoxy properly stored, handled and applied under normal
mortar or a suitable Sika® cementitious mortars. conditions in accordance with Sika's recommenda-
tions. In practice, the differences in materials, sub-
Injection of cracks on horizontal / vertical planes: strates and actual site conditions are such that no war-
Sikadur®-55 LP IN can be injected under pressure into ranty in respect of merchantability or of fitness for a
cracks using a single-component injection pump. The particular purpose, nor any liability arising out of any
injectors should be placed at a distance of 25 cm and legal relationship whatsoever, can be inferred either
the fissure between sections of injectors should be su- from this information, or from any written recom-
perficially sealed with Sikadur®-31 to avoid the loss of mendations, or from any other advice offered. The
resin during the injection process. Vertical cracks must user of the product must test the product’s suitability
be injected from the bottom up. As soon as the resin for the intended application and purpose. Sika re-
oozes through the next injector, the first must be serves the right to change the properties of its
sealed and continue the injection process from the products. The proprietary rights of third parties must
next. After completing the injection process, the in- be observed. All orders are accepted subject to our
jectors and sealing material can be removed. current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product
IMPORTANT Data Sheet for the product concerned, copies of which
Maximum width of cracks to be injected: 5 mm. Please will be supplied on request.
contact Sika Technical Services for cracks > 5 mm.
CLEANING OF TOOLS
Clean all tools and application equipment with Sika®
Colma-Cleaner immediately after use. Hardened
or cured material can only be mechanically removed.

LOCAL RESTRICTIONS
Note that as a result of specific local regulations the
declared data and recommended uses for this product
may vary from country to country. Consult the local
Product Data Sheet for exact product data and uses.

Sika India Pvt. Ltd. Contact:


620, Diamond Harbour Road Phone: +91 33 2447 2448
Commercial Complex II Fax: +91 33 2397 8688
Kolkata - 700 034 info.india@in.sika.com
West Bengal, India www.sika.in

Sikadur-55LPIN-en-IN-(06-2022)-1-1.pdf

Product Data Sheet


Sikadur®-55 LP IN
June 2022, Version 01.01
020204010010000024

3/3