Chloride Transport Modelling - Comsol
Chloride Transport Modelling - Comsol
Yang Lu¹
Edward Garboczi¹
Dale Bentz¹
Jeffrey Davis²
1 1 Engineering Laboratory
2 Materials Measurement Laboratory
National Institute of Standards and Technology
100 Bureau Drive 8615, Gaithersburg, MD 20899
mortar.
OUTLINE
Background
Image-based microstructures
X-ray CT image based 3-D microstructure
Spherical harmonic based virtual microstructure
Transport and binding model
Results
Micro-XRF measurement validation
X-ray CT microstructure simulation
Virtual concrete microstructure simulation
Conclusion
3
IMAGE-BASED MICROSTRUCTURES
Engineering Materials
Cementitious materials, asphalt
concrete
Fractured rocks in geological
systems
Subsurface fractured rocks,
Extract individual aggregate and
damaged sediments perform 3-D characterization
Medical
Bones, teeth, bio-tissues Raw 2-D sequential images
3D Reconstruction
(c) 3D tetra mesh imported into COMSOL, (d) Simulated concentration contour
then boundary and initial conditions are of the X-ray CT microstructure
applied
VIRTUAL CONCRETE MICROSTRUCTURES
Constant Cl- concentration
at the top surface
(d) 3D isosurface shows chloride (f) 2D cutting plane cross the crack at a
(e) 3D contour plot concentration at
concentration gradient existed certain position. The surface effect of
certain slices across the top crack
along the crack depth aggregate diffusivity difference is
clearly presented
The 3-D virtual microstructure was made by real aggregates represented in spherical
6
harmonic analysis. The virtual concrete model was built using a random particle
placement program (Qian 2012). The virtual concrete model has 12 irregular shape
aggregates from the VCCTL database, and a built-in crack, located on the top surface.
CHLORIDE TRANSPORT AND BINDING
MODEL
9
VERIFICATION CASE STUDY
Micro-XRF technique measurement validation
x
(a) Micro-XRF measurement
X=11.7, 12.7 20 mm
plot for chloride
1200 (b) 2-D chloride ingress contour
X=11.7 mm
1000
X=12.7 mm
Concentration (mol/m3)
800 X=20.0 mm
600
(c) The concentration data
400 was sampled at 3 fixed values 10
200 of X direction, X=11.7, 12.7,
0 and 20.0 mm of 30 days
0 5 10 15
Depth along specimen (mm)
X-RAY CT MICROSTRUCTURE RESULTS
X=26 22 20 18 mm
(a) Concentration contour plot of 3-D (b) 2-D cutting surface at Y = 5 mm
X-Ray image-based model at 30 day 1200
X = 18 mm
1000 X = 20 mm
X = 22 mm
Concentration (mol/m3)
800 X = 26 mm
600
400
200
0
0 2 4 6 8 10 12 14 16 18
Depth along specimen (mm)
X= 5 mm
1000
X = 6 mm
X = 8 mm
Concentration (mol/m3) 800 no crack
600
400
200
0
0 2 4 6 8 10 12
Depth along specimen (mm)
15