Contract N.
Vendor logo and business name Vendor Document ID
Order N.
Facility Name Location Scale Sheet of Sheets
ONSHORE n.a. 1 of 32
REVISION HISTORY
INDEX
1 PROJECT DESCRIPTION............................................................................................................... 4
1.1 General....................................................................................................................................... 4
1.2 Objective..................................................................................................................................... 4
2 DEFINITION AND ABBREVIATIONS ............................................................................................. 6
2.1 Language and unit of measurement .......................................................................................... 6
2.2 Definition..................................................................................................................................... 6
2.3 Abbreviations.............................................................................................................................. 8
3 CODES, STANDARDS AND REFERENCE.................................................................................. 11
3.1 International Telecommunication Union (ITU).......................................................................... 11
3.2 Institute of Electrical and Electronic Engineers (IEEE) ............................................................ 11
3.3 International Electrotechnical Committee (IEC) ....................................................................... 11
3.4 ENI Standards .......................................................................................................................... 12
3.5 Reference Project Documents ................................................................................................. 12
3.6 Environmental conditions ......................................................................................................... 14
4 OVERALL REQUIREMENTS ........................................................................................................ 15
4.1 General..................................................................................................................................... 15
5 TECHNICAL REQUIREMENTS .................................................................................................... 16
5.1 General..................................................................................................................................... 16
5.2 Fibre Optical Cable Type 1....................................................................................................... 16
5.3 Fibre Optical Cable Type 2....................................................................................................... 17
5.4 Fiber Optical Cable Joint Splice and Enclosure Type 1........................................................... 18
5.5 Fiber Optical Cable Joint Splice and Enclosure Type 2........................................................... 19
6 DOCUMENTATION ....................................................................................................................... 20
6.1 General..................................................................................................................................... 20
6.2 Engineering Design Documentation (Not Applicable).............................................................. 20
6.3 Construction Drawings and Documentation............................................................................. 20
6.4 Test and Commissioning Procedures ...................................................................................... 20
6.5 As-Built Drawings ..................................................................................................................... 21
6.6 System Documentation ............................................................................................................ 21
7 INSTALLATION ............................................................................................................................. 22
8 SPECIAL TOOLS AND TEST EQUIPMENTS .............................................................................. 23
8.1 Special tools ............................................................................................................................. 23
8.2 Test Equipments....................................................................................................................... 23
9 TEST AND COMMISSIONING ...................................................................................................... 24
9.1 General..................................................................................................................................... 24
9.2 Factory Acceptance Test (FAT) ............................................................................................... 24
9.3 Cable Testing ........................................................................................................................... 24
9.4 Shop Inspection Testing........................................................................................................... 25
9.5 Site Acceptance Test ............................................................................................................... 25
9.6 Certificate of Acceptance ......................................................................................................... 26
10 ATTACHMENTS ...................................................................................................................... 27
10.1 Optical Requirements Fibre Optic Cable Data Sheet Type 1 and Type 2........................... 27
10.2 Construction Requirements for Fiber Optic Cable Type 1................................................... 28
10.3 Construction Requirements for Fiber Optic Cable Type 2................................................... 29
10.4 Joint Splice Enclosure for Fibre Optic Cable Type 1 ........................................................... 31
10.5 Joint Splice Enclosure for Fibre Optic Cable Type 2 ........................................................... 31
11 ESTIMATED QUANTITIES OF FIBER OPTIC CABLE AND SPLICE CLOSURE................. 32
1 PROJECT DESCRIPTION
1.1 General
ENI has been awarded the Zubair project for the development of an oil field
(ZUBAIR FIELD) in joint venture with Occidental, Korea Gas and Missan Oil
COMPANY (as state partner), with Eni as operator.
The Zubair Field is located in the southern area of Iraq, 20 km from Basra city.
The structure of the Zubair Field is a relatively gentle anticline oriented NNW -
SE, approximately 60 km long and 10-15 km wide.
The Zubair project is a “brown field project” in which two main phases can be
defined:
1.2 Objective
The primary objective of this document is to define the minimum requirements for
the design, manufacturing, delivery, installation and testing of the FIBER OPTIC
CABLE FOR MAIN TRANSFER PIPELINES for installation between the following
SITES:
• Zubair Degassing Station;
• Zubair Mishrif Degassing Station;
• Hammar Degassing Station;
• Hammar Mishrif Degassing Station;
• Rafidiya Degassing Station;
• Safwan flow station;
• New Tankfarm;
• Field Office District;
• Fiscal Metering Site (If located outside DGS);
The FIBER OPTIC CABLE FOR MAIN TRANSFER PIPELINES shall be the
physical support to the WAN over FOC System that provides communications for
voice, data, security and monitoring/detection services and between Zubair Field
Degassing Stations, New Tankfarm and FOD SITE.
The FIBER OPTIC CABLE FOR MAIN TRANSFER PIPELINES shall be installed
by CONTRACTOR between Degassing Stations, New Tankfarm and FOD SITE,
along new main oil transfer pipeline.
All CONTRACTOR ITEMS necessary for the safe and satisfactory operation of
the system shall be included notwithstanding exclusions or omissions from the
specification.
2.2 Definition
CONTRACTOR ITEMS Means any and all itemised and non itemised
equipment and materials, including construction
spares, special tools, commissioning spares and
consumables to be incorporated into the
FACILITY or used during the plant
commissioning, start up or operations and
necessary for the due performance of the
by CONTRACTOR to COMPANY
2.3 Abbreviations
AC or ac Alternating Current
ACS Access Control System
ACSR Aluminum Conductor Steel Reinforced
ATEX Atmospheres Explosive (Directive 94/9/EC)
BOPD Barrels of Oil per Day
BSTB Billion of Stock Tank Barrels
Cat-6 Category 6
CCD Charge Coupled Device
CD Compact Disc
CCR Central Control Room
CCTV Closed Circuit Television
CED Contract Effective Date
CLI Calling Line Identifier
CMCS Central Monitoring Communication System
COE Common Operating Environment
CPI Corrugated Plate Interceptor
dB Decibel
DC or dc Direct Current
DHCP Dynamic Host Configuration Protocol
DISA Direct Inward System Access
DVR Digital Video Recorder
DGS DeGassing Station
DTMF Dual Tone Multi Frequency
DVD Digital Versatile Disc
EExe European Area of Use Standard – Increased Safety EN50019
EIA Electronics Industries Alliance
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
EP Enhanced Phase
EPC Engineering, Procurement and Construction
Fps Frames Per Second
FAX Facsimile document transmission
FO Fiber Optic
FOC Fiber Optic Cable
FOD Field Operation Division
FOPIMS Fiber Optic Pipeline Monitoring System
GUI Graphic User Interface
Ex Certification for Hazardous Area
HF High Frequency
HMI Human Machine Interface
HOFR Heat and Oil Flame Resistant
Hz Hertz
I/O Input/Output
ICSS Integrated Control & Safety System
IDF Intermediate Distribution Frame
IDS Intrusion Detection System
IEC International Electro technical Committee
IEEE Institute of Electrical & Electronic Engineers
IP Internet Protocol
IPTV Internet Protocol TeleVision
IR Infra-Red
IS International System
ISO International Organization for Standardization
ISP Internet Service Provider
IT Information Technology
ITU International Telecommunication Union
kHz Kilo Hertz
kV Kilo Volt
LAN Local Area Network
LCD Liquid Crystal Display
LCR Least Cost Routing
LED Light Emitting Diode
LER Local Equipment Room
LS0H Low Smoke Zero Halogen
LSB Life Support Base
LSC Life Support Camp
Mb/s Megabits per second
MAC Media Access Control
MDF Main Distribution Frame
MF Medium Frequency
MHz Mega Hertz
MLV Main Valve Line Station
MPEG Moving Pictures Expert Group
MPS Main Pumping Station
MSDC Main Supervisory Dispatching Centre
MTBF Mean Time Before Failure
MTG Main Telecom Ground
MTTR Mean Time To Repair
NMS Network Management System
NTP Network Time Protocol
NTSC National Television System Committee
NVR Network Video Recorder
OHL Over Head Line
OPGW OPtical Ground Wire
OSI Open System Interconnection
PAGA Public Address & General Alarm
PAL Phase Alternation Line
PoE Power over Ethernet
PS Pump Station
PSTN Public Switched Telephone Network
PTZ Pan Tilt Zoom
RF Radio Frequency
RFI Radio Frequency Interference
CONTRACTOR ITEMS and systems should normally comply with the relevant
national and international recommendations of the ITU and should be type-
approved by the national authority for use in the application proposed.
4 OVERALL REQUIREMENTS
4.1 General
This specification details the design and characteristics for the FIBER OPTICAL
CABLE FOR MAIN TRANSFER PIPELINES used for Zubair Field.
The FIBER OPTICAL CABLE FOR MAIN TRANSFER PIPELINES used for
Zubair Field shall be used for data and voice connection between DGS, New
Tankfarm, Power Plant, Gas Treatment, Sea Water Intake, remote manifolds and
FOD SITE.
WAN over FOC, pipeline monitoring and integrity signals (includes leak detection
and third party intrusion detection) shall be exchanged between sites through
backbone of FIBER OPTICAL CABLE FOR MAIN TRANSFER PIPELINES.
For that purpose, four cables shall be laid along main transfer pipeline:
• n° 2 (two) cable shall be used for WAN over FOC
• n° 2 (two) cables shall be used for pipeline monitoring system (FOPIMS)
This section gives the minimum requirements, reference standards, tests and
supply conditions for the supply of the fibre optical cables for Zubair Field.
5 TECHNICAL REQUIREMENTS
5.1 General
FIBER OPTICAL CABLES FOR MAIN TRANSFER PIPELINES (here called Type
1 FOC and Type 2 FOC) shall be supplied by SUBCONTRACTOR and shall be
suitable for direct buried installation together with Oil pipelines, Gas pipelines,
water pipelines and multiphase trunklines.
Type 1 FOC and Type 2 FOC quantity shall be defined by CONTRACTOR during
engineering design considering at least 10% of spare quantities plus quantities
above considered plus at least 10m for each manhole during installation.
Type 1 FOC and Type 2 FOC shall be included in the FOC SUBCONTRACTOR
scope of supply.
Type 1 FOC shall be used for WAN over FOC system, while Type 2 FOC shall be
used for pipeline monitoring system (FOPIMS).
FIBER OPTICAL CABLE Joint Splice Enclosures (here called Type 1 Enclosure
and Type 2 Enclosure) shall be supplied by SUBCONTRACTOR and shall be
suitable for direct buried installation. Type 1 Enclosure shall be used for Type 1
FOC splice enclosures while Type 2 Enclosure shall be used for Type 2 FOC
splice enclosures.
The Fibre Optical Cables Type 1 (Type 1 FOC) shall be of Corrugated Steel Tape
Armoured, Loose Tubes Single Mode type (SM), suitable for direct burial
installation. The number of cable cores shall be 96
The tubes shall be filled with filling compound and stranded, together with fibres,
around a central dielectric strength member (FRP) to form a compact and circular
core. Loose tube with 12 or 24 fibres shall be acceptable.
Around the loose tube and fillers, polyester tape shall be applied. Over the cable
st
core a 1 intermediate black PVC sheath shall be applied.
Over the 1st intermediate sheath, to prevent cable from petrochemical and
chemical compounds an inner jacket of Aluminium tape (coated on both side with
a copolymer), HDPE and Nylon (PA) shall be applied.
Each single mode Optical fibre shall be designed to provide good performance at
both 1310nm and/or 1550nm. The geometric and transmission characteristics
shall fully comply with ITU-T-G-652D (06/2005).
Colour coding and labelling shall be according to IEC 60304. The colour-coding
system shall be discernible throughout the design life of the cable.
Cable markings shall be printed on the outer fibre cable jacket. The markings
shall be permanent, insoluble in water and shall be legible for the duration of the
cable life.
Markings shall be printed at intervals not exceeding 2m. The outer jacket of fibre
optical cable shall be printed as follow:
• Manufacturer name (MMMMM)
• Date of fabrication (mm/yyyy)
• Project name (Zubair Field Development Project)
• Fibre type (FO24 SM)
The fibre optical cable’s mechanical characteristics shall comply with the
following:
Drum length shall be no shorter than 4000 m. The “FO Cable Drum Schedule”
shall be provided by CONTRACTOR.
The service life for fibre Optical cable shall be 25 years minimum.
F.O.C. SUBCONTRACTOR shall provide the Fibre Optical Cable Technical Data
Sheets for supplied FO cable and the “Recommendations for FO Cable
Installation and Laying”.
For more details on FOC see “Fibre Optical Cable Data Sheet at par. 11.1.and
11.2
The Fibre Optical Cables Type 2 (Type 2 FOC) shall be of Corrugated Steel Tape
Armoured, Loose Tubes Single Mode type (SM), suitable for direct burial
installation. The number of cable cores shall be 24.
The tubes shall be filled with filling compound and stranded, together with fibres,
around a central dielectric strength member (FRP) to form a compact and circular
core. Loose tube with 6 or 8 fibres shall be acceptable.
Around the loose tube and fillers, polyester tape shall be applied. Over the cable
st
core a 1 intermediate black PVC sheath shall be applied.
Over the 1st intermediate sheath, to prevent cable from petrochemical and
chemical compounds an inner jacket of Aluminium tape (coated on both side with
a copolymer), HDPE and Nylon (PA) shall be applied.
Each single mode Optical fibre shall be designed to provide good performance at
both 1310nm and/or 1550nm. The geometric and transmission characteristics
shall fully comply with ITU-T-G-652D (06/2005).
Colour coding and labelling shall be according to IEC 60304. The colour-coding
system shall be discernible throughout the design life of the cable.
Cable markings shall be printed on the outer fibre cable jacket. The markings
shall be permanent, insoluble in water and shall be legible for the duration of the
cable life.
Markings shall be printed at intervals not exceeding 2m. The outer jacket of fibre
optical cable shall be printed as follow:
• Manufacturer name (MMMMM)
• Date of fabrication (mm/yyyy)
• Project name (Zubair Field Development Project)
• Fibre type (FO96 SM)
The fibre optical cable’s mechanical characteristics shall comply with the
following:
Drum length shall be no shorter than 4000 m. The “FO Cable Drum Schedule”
shall be provided by CONTRACTOR.
The service life for fibre Optical cable shall be 25 years minimum.
F.O.C. SUBCONTRACTOR shall provide the Fibre Optical Cable Technical Data
Sheets for supplied FO cable and the “Recommendations for FO Cable
Installation and Laying”.
For more details on FOC see “Fibre Optical Cable Data Sheet at par. 11.1.and
11.3
The splice enclosures shall be suitable for a single mode FOC according to the
“Fibre Optical Cable Accessories” Data Sheets indicated. In every splice
enclosure, the cables shall be marked upon entry indicating the destination of
each cable end.
The service life for splice enclosures for aboveground and underground
applications shall be 25 years minimum.
The splicing enclosures for all FOCs covered by this Specification are included in
the scope of supply of the F.O.C. Vendor.
Joint splice closure quantities for FOC Type 1 shall be defined during engineering
design phase with following criteria: n°1 joint splice closure shall be considered
The splice enclosures shall be suitable for a single mode FOC according to the
“Fibre Optical Cable Accessories” Data Sheets indicated. In every splice
enclosure, the cables shall be marked upon entry indicating the destination of
each cable end.
The service life for splice enclosures for aboveground and underground
applications shall be 25 years minimum.
The splicing enclosures for all FOCs covered by this Specification are included in
the scope of supply of the F.O.C. Vendor.
Joint splice closure quantities for FOC Type 2 shall be defined during engineering
design phase with following criteria: n°1 joint splice closure shall be considered
every 4 km plus 10% spare of the total quantities.
6 DOCUMENTATION
6.1 General
Construction Drawings and Documentation shall include, but not limited to:
Equipment service manuals shall permit the maintenance and repair of the
equipment by trained and qualified technicians. The manuals shall contain circuit
diagrams, part lists, test and alignment procedures and measurement
parameters required to ensure that the equipment may operate within the
intended design of type approval specifications.
Equipment and system documentation shall include, but not limited to:
• User manuals
• System operation manuals
• Maintenance procedures
• Equipment technical and service manuals
7 INSTALLATION
For Fiber Optic Cables installation please refer to document n°
00250600BCST49051 “Technical specification for Fiber Optic Cable Installation”
and to document n° 00250600BCDQ49101 “Typical Installation Details for FOC”.
SUBCONTRACTOR shall supply test equipments for the normal operation and
maintenance of the system. These test equipments shall be different and
separate from the test equipments used by CONTRACTOR to perform his
installation and commissioning works.
Test equipments shall be delivered in a new and unused condition directly to
COMPANY and shall not be used for installation and commissioning activities.
All test equipments shall have a valid calibration labels and certification traceable
to known international standards.
9.1 General
Each particular cable length shall be factory acceptance tested and shall be
delivered together with the respective test reports.
• Attenuation tests of each fibre at 1310 +30/-15 nm and at 1550 +30/-70
nm with OTDR according to IEC 60793-1 (Parts 1-40 to 1-49)
• Dispersion tests of each fibre at 1310 and 1550 nm according to IEC
60793-1 (Parts 1-40 to 1-49) shall be performed.
• Zero dispersion slope shall be performed.
Dimensional Tests
Dimensions shall also be tested random (one for each cable length) during the
manufacturing process.
After cable installation activities at site, a Site Acceptance Test (SAT) will be
carried out in order to verify the full operational functionality of the system and
witnessed by COMPANY personnel who shall certify the acceptance of the
system.
The SAT will be conducted at first on stand-alone system equipments and then
on networked equipments, where applicable.
Prior to the SAT activities, SAT procedures will be supplied by
SUBCONTRACTOR for CONTRACTOR/COMPANY approval.
All SAT tests shall be documented with the result obtained and their success or
failure. Test results shall be submitted to COMPANY prior to clearance of the
SAT Test results shall include a list of test equipment used with last calibration
date and the acceptable period between calibrations.
10 ATTACHMENTS
10.1 Optical Requirements Fibre Optic Cable Data Sheet Type 1 and Type 2
sheet
FIBRE OPTIC CABLE DATA SHEET Type 1 – Type 2 1/3
No. Description Unit Required Guaranteed (*) Notes
1 Optic fibers Type 1 – Type 2
1.1 Standards
1.1.1 Product specification ITU-T G.652D
1.2 Construction Requirements
Mode field diameter at 1310 nm µm
1.2.1
at 1550 nm µm
1.2.2 Cladding diameter µm 125.0 ± 1.0
1.2.3 Coating diameter µm 245 ± 10
1.2.4 Cladding non-circularity % ≤ 5.0
1.2.5 Core/Cladding concentricity error µm ≤ 0.6
1.2.6 Cladding/Coating concentricity error µm ≤ 12.5
Core refractive index
1.2.7 Index profile
Structure material Doped silica glass
1.2.8 Cladding material Silica Glass
Dual Layer UV
1.2.9 Primary coating material
Cured acrylate
1.3 Optical Characteristics
Attenuation 1,2 at 1310 nm dB/km ≤ 0.36
1.3.1 at 1550 nm dB/km ≤ 0.25
Max average value between
dB/km ≤ 0.45
1285 and 1330 nm
Local Attenuation (point of attenuation)
dB/km ≤ 0.10
1.3.2 at 1310 nm
at 1550 nm dB/km ≤ 0.10
Dispersion value at 1550
Ps/nm·km
nm
1.3.3 between 1285 and 1130 nm Ps/nm·km
Zero dispersion wavelength, λ0 nm 1300 ≤ λ0 ≤ 1324
Zero dispersion slope Ps/nm2 ·km ≤ 0.092
1.3.4 Cable cut-off wavelength nm ≤ 1260
1.3.5 Macro bending 4 loss at 1550 nm dB ≤ 0.05
Note:
1 : Temperature : +20°C ± 3°C
2 : λ : 1310 nm = 1310 +30/-15 nm , 1550 nm = 1550 +30/-70nm
3 : Polarization Mode Dispersion
4 : Bend test : 100 turns on a 60 mm diameter mandrel
Guaranteed
No. Description Unit Required Notes
(*)
2 96 Cores Fiber Optic Cable Type 1
2.1 General
2.1.1 Product specification IEC 60794-3
2.1.2 Number of fibers No. 96
2.1.3 Lifetime yrs ≥ 25
According to cable
2.1.4 Cable length (per drum) km ≥ 4 ( ±0,1)
drums schedule
According to
Temperature operational °C -5 to +60 (IEC 60794-1-2-F1)
2.1.5 laying °C -10 to +40
storage °C -30 to +70
2.1.6 Central Strength Member (CSM) mm 2.0 - 2.6 (FRP)
2.0 - 2.5 (PBT 12 or
2.1.7 Loose tube mm 24 fiber for each
loose tube)
Four or three loose
2.1.8 Cable core tube and filler
stranded around CSM
Swellable tape or
2.1.9 Core filling: dry core or flooded
Compund
2.1.10 Wrapping Included
2.1.11 1st Inner Sheath (6,7) mm 1.0 (PVC)
Aluminum Tape mm 0.15 + 0.04
2.1.12 HDPE mm 1.0
Nylon (PA) mm 0.5
Corrugated Steel
2.1.14 Armoring
Tape
2.1.15 Outer Sheath mm 2,5 (FR PVC)
2.1.16 Weight per drum Kg
2.1.17 Outer Diameter mm
2.2 Additional Construction Requirements
Minimum Bending Radius during According to
2.2.1 20 x Cable Diameter (IEC 60794-1-2-E11)
installation
15 x Cable Diameter According to
2.2.2 Minimum Bending Radius without force (IEC 60794-1-2-E11)
Maximum crush resistance 4000 According to
2.2.4 N/10cm
(Short term) (IEC 60794-1-2 E3)
Maximum crush resistance 1000 According to
2.2.5 N/10cm
(long term) (IEC 60794-1-2 E3)
3200
According to
2.2.6 Tensile Strength (Short Term) N (fibre strain <0.33%)
(IEC 60794-1-2-E1)
1400
According to
2.2.7 Tensile Strength (Long Term) N (zero fibre strain)
(IEC 60794-1-2-E1)
Note:
5 : Filling compound in tubes and cable core must not impair the colour of the secondary coating, must be easy removable from
primary and secondary coating, must be non-toxic, scentless and harmless to human skin
6 : According to IEC 60811-4-1
7 : According to IEC 60189-1
Guaranteed
No. Description Unit Required Notes
(*)
2 24 Cores Fiber Optic Cable Type 2
2.1 General
2.1.1 Product specification IEC 60794-3
2.1.2 Number of fibers No. 24
2.1.3 Lifetime yrs ≥ 25
According to cable
2.1.4 Cable length (per drum) km ≥ 4 ( ±0,1)
drums schedule
According to
Temperature operational °C -5 to +60 (IEC 60794-1-2-F1)
2.1.5 laying °C -10 to +40
storage °C -30 to +70
2.1.6 Central Strength Member (CSM) mm 2.0 - 2.6 (FRP)
2.0 - 2.5 (PBT 8 or 12
2.1.7 Loose tube mm fiber for each loose
tube)
Eight loose tube and
2.1.8 Cable core filler stranded around
CSM
Swellable tape or
2.1.9 Core filling: dry core or flooded
Compund
2.1.10 Wrapping Included
2.1.11 1st Inner Sheath (6,7) mm 1.0 (PVC)
Aluminum Tape mm 0.15 + 0.04
2.1.12 HDPE mm 1.0
Nylon (PA) mm 0.5
Corrugated Steel
2.1.14 Armoring
Tape
2.1.15 Outer Sheath mm 2,5 (FR PVC)
2.1.16 Weight per drum Kg
Note:
5 : Filling compound in tubes and cable core must not impair the colour of the secondary coating, must be easy removable from
primary and secondary coating, must be non-toxic, scentless and harmless to human skin
6 : According to IEC 60811-4-1
7 : According to IEC 60189-1
FROM TO
TOTAL TOTAL
____ Km N° ____
(F.O.C)
(Joint Splice Closure)
FROM TO
TOTAL TOTAL
____ Km N° ____
(F.O.C)
(Joint Splice Closure)