Professional Documents
Culture Documents
Display Features Gen 1
Display Features Gen 1
Emergency Stop
System Start Up
Upon start up any error messages must be acknowledged by selecting the Enter
button once for each error message.
F1 Display Status
Enter
F1 Display Status
F1 Display Status
You can call up the sub-menu memory error from this status display in order
to see already acknowledged error messages.
F1 Display Status
You can call up further existing errors with both of the membrane
switches next to the display.
F1 Display Status
The status of the critical load control is shown on the third line.
Main Hoist
Auxiliary Hoist
Derricking Gear
Telescoping Gear
Slewing Gear
You can scroll through all power units with both of the membrane
switches next to the display.
You can adjust the speed values with both of the membrane
switches next to the display.
Once the desired valve is displayed, select the Enter membrane switch to
save the entry.
Press the membrane switch to turn the Critical Load Control ON.
Press the membrane switch to turn the Critical Load Control OFF.
If an error occurs with either of the control levers an error message will
be displayed. At this point you will be able to select the Control Lever
Emergency Program by selecting the F3 membrane switch.
Enter
X – Axis = Y – Axis =
Telescope Status
When the telescope cylinder is unlocked the display shows the current
length in feet or meters of the telescope cylinder in the lower right corner of
the display.
> 35 <
When the telescope cylinder is pinned to a section the display shows which
section the cylinder is pinned to in brackets > < along with the percentage of
extension. The lower left corner of the display shows the telescoping section
pinned to and the lower right corner shows the extension percentage.
SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 0 - 0 - 0 - 0
SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 50 - 0 - 0 - 0
If the four green light diodes above the first line flash three times after the
tele automatic has been started, you have entered a telescoping which is not
permissible according to the lifting capacity table. Furthermore, the display
shows the submenu for entering and you can enter a new permissible
telescoping.
Selecting the F5 membrane switch enters the set telescope status after
emergency operation. In order to select the menu the switch must be pressed
three times in a row within 2 seconds. This menu is required if telescoping was
done in emergency mode. Once the status is set, a key code must be entered
to resume operation. (Enter - Up Arrow - Down Arrow - Enter)