Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

VERSION 1 ECOS / SUPERSTRUCTURE

ECOS Control and


Display Panel
Telescope / Lift Select Lamp

Boom Status Display Position of Cylinder head to


Section.
To High, To low Lamps
Section pins unlocked
(red) or locked (green)
Cylinder pins unlocked
(red) or locked (green)

Emergency Stop

Grove Manitowoc National Crane Potain


1 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

Crane Control Display Navigation Membrane Switches

F1: Display Status


F2: Power Unit Speeds / Critical Load Control
F3: Control Lever Emergency Program
F4: Telescope Status & Tele Automatic
F5: Set Telescope Status after Emergency Operation
“ESC”: Escape permits backing out of some selections
“Enter”: Permits Conformation of Data Selections

Grove Manitowoc National Crane Potain


2 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

System Start Up

Acknowledging Error Messages

Upon start up any error messages must be acknowledged by selecting the Enter
button once for each error message.

Grove Manitowoc National Crane Potain


3 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status

By selecting the F1 membrane switch you can display the


operating hours of all power units and possibly read off any existing
malfunctions.

Grove Manitowoc National Crane Potain


4 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status Menu Structure

Enter

Engine Status Report Telescoping Status Report

System Status Report Locking System Status Report

Main Hoist Status Report Slewing Status Report

Aux. Hoist Status Report Aux. Drive Unit Status Report

Critical Load Control


Derricking Gear Status Report Status Report

Grove Manitowoc National Crane Potain


5 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status

Use buttons to scroll to different screens.

Grove Manitowoc National Crane Potain


6 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status

Memory Error Sub-menu

You can call up the sub-menu memory error from this status display in order
to see already acknowledged error messages.

Press the membrane switch next to the status display to do so.

Grove Manitowoc National Crane Potain


7 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status

Memory Error Sub-menu

You can call up further existing errors with both of the membrane
switches next to the display.

Grove Manitowoc National Crane Potain


8 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F1 Display Status

Critical Load Control

The status of the critical load control is shown on the third line.

ON – critical load control is switched on


OFF – critical load control is switched off
ERROR – error has occurred

Grove Manitowoc National Crane Potain


9 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

By selecting the F2 membrane switch you can enter the maximum


speed of all power units.

Grove Manitowoc National Crane Potain


10 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control


Menu Structure
Enter

Main Hoist

Auxiliary Hoist

Derricking Gear

Telescoping Gear

Slewing Gear

Critical Load Control

Grove Manitowoc National Crane Potain


11 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

You can scroll through all power units with both of the membrane
switches next to the display.

Grove Manitowoc National Crane Potain


12 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

Press the membrane switch to highlight and adjust normal speed.

Press the membrane switch to highlight and adjust jib speed.

Grove Manitowoc National Crane Potain


13 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

You can adjust the speed values with both of the membrane
switches next to the display.

Once the desired valve is displayed, select the Enter membrane switch to
save the entry.

Grove Manitowoc National Crane Potain


14 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

Press either membrane switch to highlight Critical Load Control status.

Grove Manitowoc National Crane Potain


15 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control

Press the membrane switch to turn the Critical Load Control ON.

Press the membrane switch to turn the Critical Load Control OFF.

Press the Enter membrane switch to save the entry.

Grove Manitowoc National Crane Potain


16 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F3 Control Lever Emergency Program

If an error occurs with either of the control levers an error message will
be displayed. At this point you will be able to select the Control Lever
Emergency Program by selecting the F3 membrane switch.

Grove Manitowoc National Crane Potain


17 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F2 Power Unit Speeds / Critical Load Control


Menu Structure

Enter

Control Lever Right

Control Lever Left

Grove Manitowoc National Crane Potain


18 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F3 Control Lever Emergency Program

Once the F3 membrane switch has been selected operation of the


disabled control function can be performed by using the directional
arrow membrane switches on the display along with the control lever.

X – Axis = Y – Axis =

Grove Manitowoc National Crane Potain


19 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

Selecting the F4 membrane switch opens the Telescoping display.


This screen allows you to monitor current telescope status or enter
automatic telescoping mode.

Grove Manitowoc National Crane Potain


20 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

Telescope Status

The Telescope Status shows the current position of each telescoping


section. The above example shows all sections are at 0% extended.

Grove Manitowoc National Crane Potain


21 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

Telescope Cylinder Unlocked

When the telescope cylinder is unlocked the display shows the current
length in feet or meters of the telescope cylinder in the lower right corner of
the display.

Grove Manitowoc National Crane Potain


22 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

> 35 <

Telescope Cylinder Pinned to a Section

When the telescope cylinder is pinned to a section the display shows which
section the cylinder is pinned to in brackets > < along with the percentage of
extension. The lower left corner of the display shows the telescoping section
pinned to and the lower right corner shows the extension percentage.

Grove Manitowoc National Crane Potain


23 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 0 - 0 - 0 - 0

Programming Tele Automatic

Selecting the F4 membrane switch while in the telescope status screen


opens the Set Tele Automatic screen. In addition the entry request ( )
flashes on the numerical value for T1.

Grove Manitowoc National Crane Potain


24 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic

SET TELEAUTOMATIC
T1 - T2 - T3 - T4 - T5
0 - 50 - 0 - 0 - 0

Programming Tele Automatic

Use the membrane switches to scroll between sections T1 – T5.

Use the membrane switches to change the extension value for a


section. Once all values are entered selecting the Enter membrane switch
activates the system.

Grove Manitowoc National Crane Potain


25 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F4 Telescope Status & Tele Automatic


Flashing Warning Lights

If the four green light diodes above the first line flash three times after the
tele automatic has been started, you have entered a telescoping which is not
permissible according to the lifting capacity table. Furthermore, the display
shows the submenu for entering and you can enter a new permissible
telescoping.

Grove Manitowoc National Crane Potain


26 Display Features
VERSION 1 ECOS / SUPERSTRUCTURE

F5 Set Telescope Status after Emergency Operation

SET TELESCOPE STATUS


T1 - T2 - T3 - T4 - T5
0 - 0 - 0 - 0 - 0
Key Code: _ _ _ _

Selecting the F5 membrane switch enters the set telescope status after
emergency operation. In order to select the menu the switch must be pressed
three times in a row within 2 seconds. This menu is required if telescoping was
done in emergency mode. Once the status is set, a key code must be entered
to resume operation. (Enter - Up Arrow - Down Arrow - Enter)