FERS BAR DAMME 11
Notice of Unsealing automatic—control self-priming Pump
Adjustment and Safeguard Operation
KF Ak RR
Tian Li Pump
38 DURCO Siete
Using the advanced technologies
Of American DURCO
re BULK ry sae
Manufactured by Jiang su Jingjiang City Tianli Pump Co.Ltd.RAK RAK
Tianli Pump Debugging
BAM, WEB GH BAR NAT a BEAT AT
Dear customers,
Before adjusting WEB series of Unsealing automatic -control self—priming Pump, please
read the notice below:
1-1, AREA PLE TBR, Face RE AY He SEB
Pio ROAR ALES AE. ESTE hl AL LER EC HLH LEIS
eT A AE TT7 T A
Check if the power supply voltage meet the operation requirement of motor, whether the
voltage value is within the prescribed scope. Check whether the electric control system,
frequency conversion control and the electrical wiring and other equipment are correct and in
good condition, When turning on the power and starting the motor, check the operating direction
is the same as the one specified by pump(counterclockwise).
1-2. HEF ANAS ARERR AA OO Ds iB FTE EEA EM ETT SRE
eS TRIBES aR ae PE A LE BENE
PER TAMATHEKA RA, WE URRA READS ER,
FE LA Aa LBS, WER A EMR ek RK OE CO
Please check carefully whether the filter screen which must be installed in the liquid inlet
pipe inlet is installed or not.Check whether the rubber pad and screws between the liquid inlet
pipe inlet and the flange paired with the pump are fastened or not. Check whether there are any
ostioles or missing welding in the elbows in the liquid inlet pipe inlet.Check whether the liquid
inlet pipe inlet has series connection or additional. pipe respectively for other water pump. If so,
close the valve on the series connection and additional pipe to form a closed loop and ensure
self-priming and flowing liquid ,and then check whether every nut on the pump is fitted.
i2. NEES | BAER. FL RENO LE HE TBE AN AS} CAST 68
BK HHL ELBE BS SBE A te TP NR | DRE,
STORE I, Qa RSH a ee La, aL
UE (ALLA CS) PADI TA AR HL FT TT ME
Fill drainage liquid, Fill drainage liquid in draft opening. Fill different kinds of drainage
liquid when transmitting different media.Usually you can see directly if the drainage liquid is
full, Or you can open the ball valve in the pump case,if drainage liquid flow out,it shows that
the drainage liquid is full. Then tighten the nut,start all the valves in the liquid outlet net,in—
cluding the atmospheric valve (empty valve)in the liquid outlet net,in case that too high fluid
pressure may damage the valve or the pump will explode,
3-1. BERLAMER AT ARE THREE LH ETT HY ASE BEAT
PEGA FABRA 2 PaaS
SCP ANAK FREED, DE HE CEL AE LEE ER ET
Wo HERE Ti; AK WA. WKREA RS BEE
fh, SEMA FOR HPAES AL GREE SBOE
FSG, OUR HAC, AL AY METAS A ETT , LA
FRSA ERA, BAR IE ST RL
Flow and pressure test. When the pump leaves the factory it is manufactured and produced
according to the data of the contract documents and technical documents signed by the supply
and demand sides,and it is tested for many times and meets the standard. When the user ad~
justs the pump, please refer to the control contract documents and pump nameplate, and
check if the pressure gauge in the liquid outlet net is effective, and then adjust the valve.
Usually high pressure, low flow;low pressure, large flow. If pressure is too high (higher
than level in prohibition )water~pump will mix gently and spray out from the connection
‘of the motor and pump with allophone. If pressure is too low ( lower than level in prohibi-
tion ),water—pump flux will augment,the motor will get hot,some time later, the motor
bearing lubrication oil will rapidly melt, bearing will dry grind,and it will damage the
motor or cause other breakdowns.
3-2, BC Pie ALLE A QE EA TE ALLS
—2—HEB Peo ANAT BL LRT ILS ALC, AA EA HIE
Prompting: Please use correetly under the provisions of the contract at Q, H range,make
sure motor doesn’t exceed electricity.We will not answer for any situation mentioned above.
4. FLINT. DERBI VAL PA AS ACT ERE ZH
FRAC ELBE A ET TE. AR FRE BU ACE OU, YTD
ERE 20 FERRE. FA ANAT RE CE, BU EHS By et
Ml, MUA T. PELL ASSS 44 TUE 18 A
Self—priming time, Liquid inlet diameter size and horizontal tube distance the vertical
depth of the pool surface and the negative pressure condition will affect self-priming time. The
shorter the distance between the pump inlet and the water level is,the better. The higher the
distance between the surface vertical depth and0 jis, the better. Don’t enlarge the liquid inlet
pipe diameter casually, otherwise the self-priming time will be longer,and it will cause motor to
exceed electricity. Details refer to NO.18 on Page 44 of the use manual.
Sa 1. YELENA KEIR. MU FLAABLLA 1000 2K 27H, 1000 2K
HE 1500 KZ 2000 KZ 2500 KLE ,500 KAVA, ALA MELE BEA A ARAB
RADY AY AE HBL. AK FE I EEL EE A EA
The requirements of altitudes for sclf-priming pump.The motor of conventional pump is
bounded by 1 000 meters, 1 000m->+1500m—+2000m—+2500m, when the altitude arises every
500m, you should use the same grade plateau energy-saving motor. The shorter the vertical
depth of pump suction is, the faster water velocity is.
5-2. PURER. “KN” TCE A RACE ALP SOR BSE bk RE
TB LP a CEES GRE Aa TAL PH BOR, Be we eR bk Be BEE PIL TSB
PEER HW.
Rapid selfpriming. The unsealing automatic—control selfpriming Tian Li Pump will meet
the consumers’ demands of fast water supply. Consumers should put forward the requirements in
the contract when placing orders. We will produce and manufacture according to fast water sup~
ply device to suck the liquid rapidly.
=3-RAR AWA
Tianli Pump Structure Drawing
TTeclorkingacie
i oo
a |
att at
3 i : yaa
ony inpeler
a Into ipo
hee A T =a
tee t 1
conta ale i t x
i
siete
= - A Tiida —
“alt i theck-presre ab)
|
| meal “be
sem Hl) “ 5
‘timed i
|
| i sia
| | i
ik
i jane
sis aa
aa ale |
eh
\
I
|KR Fl IK RR He
Tianli Pump Safeguard
1. HYG LE FEL) SASS STIPE SSCA. PEALE BH LISSA Peer,
FURRY AR SEERA $5 HBAS ZK ARES MK. THES BE Hw LAR BR
MERRARRE.
‘The back~pressure valve in the liquid outlet will open automatically in dynamic state and
it will close automatically in static state, The funetion is to prevent water vertical pressure dam~
aging the impeller when power is cut off suddenly or the pump stops.
2. AL BNAS EHR» PPE EPR TT UCL BLS) , AAG A LSA HES LI,
SEAR AI TC BREN AY. CERT, HERA EIA ak
FRPEUL A REDRET IF WME EA 28, NID, ARERR 5 LEH Bk
DRYDEN , — LAIR AKAROA ZK, BEA | CRT LE FAP RE
TRUER
Electric air control valve. Its function is to not need the manual frequent filling drainage
except the first drainage,achieving the aim of unmanned operation, Its working principle is:
When the pump starts,the electric control valve closes; When the pump stops, the electric con
trol valve opens,air enters the fluid table and shuts off the rainbow-attracting. The cavity of
pump maintains the drainage fluid,not pouring reflux liquid pool. Once damaged, the pump will
sound without pumping water and the drainage fluid in the pump case will become hotter, please
check it immediately or change electric air control valve.
3. ABLATED RIA SKF AD TE ZL3 BU AR
HOWAEE <75T..
aesMost of the front-ends and back~ends in the motor bearing adopt SKF series,the grease is
713 lithium grease,and the temperature of the bearing is equal to or below 75°C.
4, ARASH LRA ORs GME AS ATE LS EDL, WR ED
FAL, PE SCHR IRALDL PY 2S SE Ih = A PRE , FRSC LF ok 2 J,
RUG, FAS Bee a i LR, PAELLA. WSR AR
SRA TEA HEAR 2 Fa LP Ye IRS be — YS TARE, FL
BAL TOT MRE HR, HT ETT.
The steps of installing and disassembling the pump and motor is;Prepare lifting equipment
and glassing machine,refer to Tian Li Pump Structure Drawing. First remove three inner hexagon
screws at the flange spindle under the motor, then remove the fastener around the flange under
the motor,and vertically lift the motor ring with lifting equipment, which can separate the motor
from the pump. If the motor shaft is fastened, please find two counter top screw holes at the
connection between flange and motor in the pump stand,push them with the screw,which ean
help disassemble, You can also use other equipment such as double jack.
5. AAR PEM AEA HG (tH is BEL BRAD RT PEO DA OF
SAARC ARI, ERLE LO Pe TRS
FEE RT TELE A AU HE A ETAT ALE, RSET
Thr ERAS , BUREDESY
‘The disassembling of the impeller and secondary impeller (sealing installation): Water pump
impeller and secondary impeller are fitted on the pump shaft,which are all counter-clockwise.
‘The solder joints on it prevent impeller reversing. Rub all the joints, knock on the impeller with
a hammer to make it flexible, thus it can be disassembled.
6. AMA PRES FUR SRE MARR E. PRE R,
6A PEK, GUE LRP ABE‘The guide bearing in the Structure Draving is fitted in double-stage and multistage pumps.
‘The single-stage one has no guide beating,and it applies to positive pressure fluid. There is no
guide bearing in negative pressure condition.
FRIGHT, RED WOT AT ICT HL LORRI AEP UE a PB
SPIE.
Your best choice is:Don‘t exceed current,don’t exceed pressure, record the operating,
and maintain the equipment according to the motor demands.
anoURte
‘electtc air
Asa)
~ liquid outtet
(back-pressure
valve)
sto
Liguid into
the mouth
Rese
‘Wansfer pump water
Toundation retaining plate
¢ 7 RNR wa
Sh inner hexagon
fastening scrows
si
ump shaft
Ersatzteilliste Typ 41-23 Spare Parts List Type 41-23 Pièces de Rechange Type 41-23 Lista Dei Pezzi Di Ricambio Tipo 41-23 Lista de Repuestos Tipo 41-23