PR 1613

System Weighing Indicator

• High accuracy W&M indicators EC


conformity certificate 5000 d acc.
to EN 4550l (corresp. to OIML R 76)
• Alibi memory for W&M
• Free programmable
• Integrated PLC, 6 inputs and 12 outputs
• Max. 4 serial interfaces (current loop,
RS 232 or RS 422/485)
• Optional: analogue inputs/putputs, BCD-
output, Parallel printer interface, Pulse
counter input, PROFIBUS-DP
• Various software options for: Weighbridge
applications, Batching applications,
Communication protocols
• Real time clock and memory
extension
• Protection class IP 65 (front)

Profile Indicator specific features Technical Data


The weight indicators PR 1613 have been • Free programmability of internal PLC and
Housing (PR 1613/00… /01)
designed for high precision weighing weighing sequences
Material: aluminium
applications e.g. for platforms, • Easy connection of barcode reader, remote
Protection class: IP 30
weighbridges, cranes or batching processes. displays, printers or PLCs
Front panel: IP 65
Operating via: • Load cell supply of 12 V or 20 V
• front panel • Automatic zero tracking
Housing (PR 1613/03… /04)
• control inputs/outputs • Multi-range scales possible (3 ranges)
Material: stainless steel
• remote display/terminal • SW- and HW options later on extendable
Protection class: IP 65
• communication from a supervisory system • Disabling keyboard functions
(Dust, JBUS/MODBUS, Teleperm, • Analogue test
Main voltage
Profibus-DP)
PR 1613/00 and PR 1613/03:
In case of alpha numerical operation as for Customer specific benefits
110 V/220 VAC, -15%/+10%, 50/60Hz
platforms or batching processes it is • Easy and comfortable operating,
PR 1613/01 and PR 1613/04:
recommandable to use the compact calibration and configuration
24 VAC -15 %/+10 %,
weighing terminal. • Calibration without weights
24 VDC -15 %/+20 %
(input of load cell identification data)
• Operator dialogue in local language
Power consumption
• Print layout adjustable
19 W / 25 VA (PR 1613/00)
• Typical weighbridge, batching and
18 W / 24 VA (PR 1613/01)
On-Board Weighing software available
22.5 W / 30 VA (PR 1613/03)
23 W / 30 VA (PR 1613/04)
PR 1613 Function Diagram

SW Option PR 1613/10 PR 1609/00 Real time clock • PR 1613/80 Memory extension In/Outputs
• Standard package runs independently of mains • PR 1613/81 Alibi memory Free programmable with SW-Option
for weightbridges (for PR 1613/03 standard) (Weights and Measures) PR 1613/10 or PR 1613/20
• Programming facilities of
the internal PLC and
weighing sequences up to 6 Load Cells 12 Outputs 6 inputs
or
SW Option PR 1613/20
• Standard programm
for batching Options
• Programming facilities Cable Junction
of the internal PLC and Box
weighing sequences
or
SW Option PR 1613/30
• On board weighing
extension
• Tilling correction
for truck mounted
weighing systems Serial lines • PR 1603/00 Double interface RS 232 + TTY
• PR 1601/00 TTY • PR 1605/00 Parallel printer interface
SW Option PR 1613/05 • PR 1602/00 RS 232 (V24) • PR 1606/00 0-10 V, 0-20 mA or 2-10 V, 4-20 mA Analog output
Different communication • PR 1604/00 RS 422/RS 485 • PR 1606/8x Analog / BCD output (only 1 serial line possible)
protocols are available: • PR 1607/00 4 Analoge inputs 0-10 V or 0-20 mA
• DUST 3964 R (only usable with PR 1613/10 or PR 1613/20)
• TELEPERM • PR 1608/xx 5 Decade BCD - output,
• JBUS/MODBUS (with PR 1613/10 or PR 1613/20 usable as 24 additional outputs)
• PR 1610/00 Pulse counter input
(optional 7 additional inputs available)
• PR 1621/00 PROFIBUS-DP

M.T.B.F. Load cell connection Temperature effects


35000 hours All strain gauge loadcells; Zero: < 0.1 µV / K RTI
6- or 4-wire connection Span: < 0.006 % / 10 K
Status indicators
->0<- zero display within = 1/4 d Load cell supply Environmental conditions
standstill 12 V/20 VDC selectable, short-circuit
Vibration safety
B gross weight display proof. External load cell supply is possible.
Acc. to IEC 68-2-6. Test Fc
NET net weight display
T tare weight display Minimum load impedance
Static discharge
Dimensions can be set for: g, kg, t,lb (internal supply)
Acc. to IEC 1000-4-2
Decimal point can be set min. 87.5 Ohm
e.g. 6 load cells with 600 ¥
Interference on mains and input/output
Display or 4 load cells with 350 ¥
Acc. to IEC 1000-4-4
Type: vacuum fluorescent display
Elements: 7 - digits (7 segments) Measuring principle
Electromagnetic field
Height: 12.5 mm Meas. amplifier: integrating converter,
Acc. to IEC 1000-4-3
Colour: bright green ratiometric to LC supply
26 MHz to 1 GHz
plus weighing and status symbols Conversion time 50 ms.
Measuring time: 0.1 s to 2 s, can be set
Radio noise suppression
Message display at intervals of 0.1 s.
Acc. to EN 55 011
(only PR1613/03../04)
2 lines with 20 characters Measuring range
Electrical safety
Structure: 5 x 7 Matrix Meas. signal: 2.4 mV to 36 mV
Acc. to IEC IEC 1010-1
(for 100 % nominal load)
Control input Dead load: 0… 33.6 mV
Temperature
Number: 6, opto-isolated There is no interaction between dead load
W&M operation: -10° C to +40° C
Max. voltage 32 VDC and measuring range setting.
industrial: -10° C to +55° C
Input current (high):
Storage: -40° C to +70° C
5 mA at 12 VDC/11 mA at 24 VDC Resolution (internal)
0.2 µV / div.
Control outputs (max. 180,000 counts)
Number: 12, opto-isolated output
Max. voltage: 32 VDC Analog filter
Max. current: 75 mA Active Butterworth low pass filter,
40 dB / decade, 2 Hz cut-off frequency
Accuracy
5000e class III acc. to EN 45 501; Linearity
corresponds to OIML R 76 < 0.007 %
Typical application by use of weighbridge programm PR 1613/10

Standard Funciotns by use of Weighbridge


Software PR 1613/10
• record the charge/discharge weight with
saving of the data
• editing of:
- customers tables
Remote Display - vehicles tables
e.g. PR 1627 - material tables
• print of customers lists material quantity
per customer
or dig outputs
• create or delete a list of all the vehicles on
the site

PR 1603/00

PR 1613/00…/01

PR 1613/03…/04
Terminal
e.g.. VT 510 z.B. PR 1602/00 RS 232
RS 232

Printer Card Reader


e.g. FX 880

Typical application by use of batching software PR 1613/20

Standard Funciotns by use of Weighbridge


Software PR 1613/20
• editing of:
Remote Display - material tables
- recipe tables
• batching process control with alarm
signals
• print of
- batching-reports
- production reports
- material consumption reports
PR 6130 Haszardous area

PR 1625/60
Interface PR 1626/60 Interface 2
IB safe area
IA TTY

RS 232
Card Reader

Printer e.g. FX 880


RS 485 RS 232
Supervisory System
Standard I/O connection (including PR 1613/10)
Output Function Output Function Input Function
1 tare active 7 pass active I set zero
2 within ±1/4 d 8 minus sign when net display 2 set tare
3 standstill 9 within zero set range 3 reset tare
4 limit 1 10 display dimmed 4 start print
5 limit 2 11 analogue/load cell/memory error 5 switch display to gross
6 W&M not fulfilled 12 analogue test active 6 switch display to net

Instrument dimensions Rear panel PR 1613/03 and /04 Rear panel PR 1613/00 Cable connections PR 1613/03
PR 1613/00 and /01

all dimensions in mm Weight net 3.6 kg / shipping 4.5 kg Weight net 9.9 kg / shipping 11.2 kg

Order information
Type Description Order numbers Type Description Order numbers
PR 1613/00 System weighing indicator 9405 116 13001 PR 1613/03 Compact weighing terminal 9405 116 13031
PR 1613/01 in 24 VAC/DC version 9405 116 13011 PR 1613/04 in 24 VAC/DC version 9405 116 13041
Hardware Options
PR 1601/00 Current loop TTY 9405 316 01001 PR 1608/00 BCD-output (open emitter) 9405 316 08001
PR 1602/00 RS 232 (V24) 9405 316 02001 PR 1608/10 BCD-output (open collector) 9405 316 08101
PR 1603/00 RS 232 + TTY 9405 316 03001 PR 1609/00 Real time clock 9405 316 09001
PR 1604/00 RS 422/485 9405 316 04001 PR 1610/00 Pulse counter 9405 316 10001
PR 1605/00 Parallel printer interface 9405 316 05001 PR 1613/80 Memory extension 9405 316 13801
PR 1606/00 Analogue output 9405 316 06001 PR 1613/81 Alibi-memory (W&M) 9405 316 13811
PR 1606/80 Analogue / BCD output 9405 316 06801 PR 1621/00 PROFIBUS-DP 9405 316 21001
(open emitter)
PR 1606/81 Analogue / BCD output 9405 316 06811 PR 1623/10 Connecting cable 9405 316 23101
(open collector)
PR 1607/00 Analogue input (4x) 9405 316 07001 PR 1623/20 Relay I/O module 9405 316 23201
PR 1623/30 Terminal I/O module 9405 316 23301
Software Options
PR 1613/10 Weighbridge-package 9405 316 13101
PR 1613/20 Batch-package 9405 316 13201
PR 1613/05 Communications-package 9405 316 13051

Sartorius Hamburg GmbH


Specifications subject to change Meiendorfer Straße 205
without notice. 22145 Hamburg, Germany
Printed in Germany.
Tel. +49.40.67960.303
n/sart • C
9498 716 13011 Fax +49.40.67960.383
Version 06.2004 www.sartorius.com

You might also like