Vulcan WB10 / WB12 Vertical Weatherboard: Sheet Index Sheet No: Revision: Sheet Name

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

Vulcan WB10 / WB12 Vertical Weatherboard

Sheet Index
Sheet No: Revision: Sheet Name:
H.V.1 02 Horizontal 20x45 Cavity Batten Fix
H.V.2 02 Horizontal 45x45 Structural Cavity Batten Fix
H.V.3 01 Base of wall - concrete floor
H.V.4 01 Base of wall - Timber floor
H.V.5 01 Inter-Storey Cavity Junction
H.V.6 01 Secret Fixing- Packer Cavity Batten - Stained
H.V.7 02 Face Fixed - Packer Cavity Batten
H.V.8 02 Structural Cavity Batten - 20x45
H.V.9 02 Structural 45x45 Cavity Batten
H.V.10 01 External 90° Corner - Boxed
H.V.11 01 External 135° Corner - Boxed
H.V.12 01 External 90° Corner - Rebated
H.V.13 01 External 90° corner-AW46 Moulding
H.V.14 01 Internal 90 Corner - Butted
H.V.15 01 Internal 90° Corner - AW46 Moulding
H.V.16 01 Internal 90° Corner - W Flashing
H.V.17 01 Internal 135° Corner - W Flashing
H.V.18 01 Enclosed Deck - Concrete Substrate
H.V.19 01 Enclosed Deck - Timber Substrate
H.V.20 01 Parapet Balustrade Cap Flashing
H.V.21 01 Parapet Balustrade Intersection With Wall - Butted
H.V.22 01 Parapet Balustrade Intersection With Wall - Flashing
H.V.23 01 Parapet Balustrade Intersection - AW6 Moulding
H.V.24 01 Meter Box Head
H.V.25 01 Meter Box Jamb
H.V.26 01 Meter Box Sill
H.V.27 01 Pipe Penetration
H.V.28 02 Weatherboard Fix - Packer Cavity Batten
H.V.29 02 Weatherboard Join - Vertical
H.V.30 01 Apron Flashing
H.V.31 01 Roof Kick-out Flashing Cavity
H.V.32 01 Top Of Wall - Flat Soffit
H.V.33 01 Top Of Wall - No Soffit
H.V.34 01 Top Of Wall - Slopping Soffit
H.V.35 01 Top of Wall Raking Soffit
H.V.36 01 Soffit Detail
H.V.37 02 Alternative Soffit 01
H.V.38 02 Alternative Soffit 02
H.V.39 01 Window Head
H.V.40 01 Window Jamb
H.V.41 01 Window Sill
H.V.42 01 Window Jamb - AW91 batten
H.V.43 01 Window Sill - AW91 batten

© Abodo Wood Ltd. 2020 SHEET TITLE

DETAIL INDEX
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. - @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V. 01
studs @ 60
0mm
crs.max. studs @ 60
0mm
crs.max.

CB-H-20x45
CB-H-20x45

CB-V-20x45
CB-V-20x45

nogs / dwangs @
480mm crs.max.

nogs / dwangs @
480mm crs.max.

Optional;
Structural Batten Fix
CB-V-20x45 & CB-H-20x45
Fixed at max. 300mm centres with
2.8x60mm S.S. ring shank flat
head nails or 8g x 50mm S.S.
screws staggered 12mm of the
centre line.

© Abodo Wood Ltd. 2020 SHEET TITLE

Horizontal 20x45 Cavity Batten Fix


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. NTS @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.1 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

studs @ 60
0mm
crs.max. studs @ 60
0mm
crs.max.

CB-H-45x45
CB-H-45x45

CB-V-45x45
CB-V-45x45

nogs / dwangs @
800mm crs.max.
optional OR As
required by
specified wall
system

Structural Batten Fix


CB-V-45x45 & CB-H-45x45
Fixed at max. 600mm centres with
4.0x90mm S.S. ring shank flat
head nails or 8g x 75mm S.S.
screws staggered 12mm of the
centre line.

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Horizontal 45x45 Structural Cavity Batten Fix


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.2 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining


Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

DPC

Cavity closer

Concrete foundation
35

Building wrap to be extended


50

35mm beyond the bottom plate

15°

E2/AS1 - Fig. 65- Minimum Ground Clearance


15 min drip

175mm min. to ground


100mm min. to paving

Base of exterior
cladding
50

Line of interior
finished floor level
225
175
150

GARAGE
100

OPENING Unpaved
Ground
Ramp
down
Exterior
20mm set down Paved
for garage door

25mm min clearance between


bottom of cladding and driveway
at garage door openings

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Base of wall - concrete floor


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.3 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Flooring

Floor framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

DPC

Cavity closer
35

Building wrap to be extended


50

Concrete foundation 35mm beyond the bottom plate

15°
175mm min. to ground
100mm min. to paving

E2/AS1 - Fig. 65- Minimum Ground Clearance

Base of exterior
15 min drip

cladding
50

Line of interior
finished floor level
225
175
150

GARAGE
100

OPENING Unpaved
Ground
Ramp
down
Exterior
20mm set down Paved
for garage door

25mm min clearance between


bottom of cladding and driveway
at garage door openings

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Base of wall - Timber floor


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.4 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Flexible flashing tape over


'z' flashing
Cavity closer
35

15mm min. drip edge


15

(Cavity closure to bottom of cladding)


5

5mm min. capillary gap

35mm 'z' flashing


15º min. slope
35mm min. upstand
35mm min. cover to weatherboard

Continuous horizontal cavity batten

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Inter-Storey Cavity Junction


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.5 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Packer battens temporarily fixed


to wall framing (Weatherboard fixing
used to permanently fix the batten)

Abodo 7g x 65mm self drilling, self


countersinking screw or 60x3.15mm
30 annular groove flat head nail to
achieve 30mm min. penetration into
stud / nog

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Secret Fixing- Packer Cavity Batten - Stained


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.6 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Packer battens temporarily fixed


to wall framing (Weatherboard fixing
used to permanently fix the batten)

70x2.8mm annular grooved rose


30mm min head nail to achieved 30mm min.
penetration into stud/nog
Nail on an upward angle

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Face Fixed - Packer Cavity Batten


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.7 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining Wall framing


Building wrap

Abodo CBH 20x45 H3.2 castellated


timber cavity batten
Abodo WB10 / WB12 weatherboard

Cavity battens structurally fixed to


wall framing with 60mmx2.8mm flat head
annular grove stainless steel nails
off-set along centre line at 300mm centres
Abodo 45mmx6g s/s cladding screw or
50x2.8mm annular groove flat head
nail to achieve 30mm min. penetration
into cavity batten and framing combined

30mm min

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Structural Cavity Batten - 20x45


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.8 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining Wall framing

Building wrap
Abodo CBH 45x45 H3.2 castellated
timber cavity batten

Abodo WB10 / WB12 weatherboard

Cavity battens structurally fixed to


wall framing with 90x3.15 s/s
annular grove off-set along
centre line at max 600mm centres

Abodo 45x6g s/s cladding screw or


40x2.8mm annular groove flat head
nail to achieve 30mm min. penetration
into cavity batten

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Structural 45x45 Cavity Batten


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.9 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing Internal wall lining

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

70x3.2mm annular groove nail


through face of weatherboard
10

Vertical cavity battens


10

91, 92 cover boards with


6 x 6mm weathergrooves

Seal boards together with


modified silicone or
construction sealant
10 10

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

External 90° Corner - Boxed


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.10 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing Internal wall lining

Building wrap

Cavity batten 10

Abodo WB10 weatherboard

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing. 50mm max.
from end of weatherboard

50 x 50mm external corner


flashing with hem
10

Epoxy adhesive at
mitre joins

Mitred 91, 92 cover boards with


6 x 6mm weathergrooves

Vertical cavity battens

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

External 135° Corner - Boxed


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.11 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing Internal wall lining

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard


10

Vertical cavity batten

50 x 50mm external corner


flashing with hem
50

10

Flashing to provide 50mm


cover behind weatherboard

Rout and Seal boards together


9

withcontinuous bead of modified


silicone or construction sealant

50mm annular groove nail 9


pre-drilled @ 400 crs 10 10

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

External 90° Corner - Rebated


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.12 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing Internal wall lining

Building wrap

Cavity batten

Abodo WB10 / WB12


weatherboard
10

Abodo AWF4 100 x 100mm


external metal corner flashing
un-hemmed
10

Seal and glue to adjacent


weatherboards
AW46 corner moulding

75mm annular grooved stainless


flat head nail - pre-drilled 10 10
Offset nails on both edges @480mm crs
Vertical cavity batten

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

External 90° corner-AW46 Moulding


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.13 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing
10
Building wrap

Cavity batten

Optional AW41 D4S corner mould


10

50

Flashing to provide 50mm min. cover


behind weatherboards

70 x 70mm internal corner


flashing with hem

Abodo WB10 weatherboard

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Internal 90 Corner - Butted


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.14 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing
10
Building wrap
Cavity batten
AW46 moulding sealed
to adjacent weatherboards
with construction sealant
eg Sikaflex 11FC
8g x 20 mm S.S. screw from back of flashing
10

@ 480 mm crs
Flashing to provide 75mm min. cover
behind weatherboards
Abodo AWF2 120 x 120mm internal
metal corner flashing un-hemmed

70x3.2mm annular groove nail


through face of weatherboard
50mm from end of weatherboard

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Internal 90° Corner - AW46 Moulding


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.15 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing
10
Building wrap

Cavity batten

Butt boards to 'W' flashing and seal


10

with continuous bead of sealant


50

Flashing to provide 50mm min. cover


behind weatherboards

70 x 70mm internal corner


'W' flashing with hem

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Internal 90° Corner - W Flashing


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.16 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

10 70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

Butt boards to flashing and seal


with continuous bead of sealant
50mm min

Flashing to provide 50mm min. cover


behind weatherboards
10

Internal corner flashing with hem

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Internal 135° Corner - W Flashing


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.17 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap
150mm min. fully supported
membrane carried up wall

Abodo WB10 / WB12 weatherboard


Building wrap lapped over
Deck membrane

Cavity batten

DPC
Cavity closer
Building wrap to be extended
Floor structure
35mm beyond the bottom plate

100mm min. finished deck surface 15° 10mm min. cavity closure to
to internal finished floor level bottom of cladding

35mm min. bottom of cladding


to highest point of decking

20mm triangular fillet Deck membrane

Deck structure

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Enclosed Deck - Concrete Substrate


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.18 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Abodo WB10 / WB12 weatherboard


Building wrap lapped over
Deck membrane

150mm min. fully supported


membrane carried up wall
Cavity batten

Cavity closer

15° 10mm min. cavity closure to


Framing to fully support membrane
bottom of cladding

35mm min. bottom of cladding


to highest point of decking
20mm triangular fillet

Deck membrane

Deck structure

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Enclosed Deck - Timber Substrate


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.19 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Metal parapet flashing


5º min. slope (1:12)
Roof underlay to provide
Parapet flashing to provide
separation between flashing
50mm min. cover over weatherboards
and timber
(70mm for very high wind zones)
H3.1 treated packer to form slope

Fix parapet flashing


through side

Drip edge

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Parapet Balustrade Cap Flashing


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.20 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

Building wrap to parapet / balustrade


lapped around corner onto wall
10

10

Wall framing

Building wrap

Cavity batten

10 Abodo WB10 /
WB12
weatherboard
Optional AW41 D4S corner mould
50mm min
10

Flashing to provide 50mm min. cover


behind weatherboards

70 x 70mm internal corner


flashing with hem

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Parapet Balustrade Intersection With Wall - Butted


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.21 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

Flashing to provide 50mm min. cover


behind weatherboards

50mm min
Building wrap to parapet / balustrade
10 lapped around corner onto wall

10

Wall framing

Building wrap

Cavity batten

10 Abodo WB10 /
WB12
weatherboard
50mm min
10

Butt boards to 'W' flashing and seal


with continuous bead of sealant

70 x 70mm internal corner


'W' flashing with hem

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Parapet Balustrade Intersection With Wall - Flashing


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.22 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

70x3.2mm annular groove nail


through face of weatherboard
to clear flashing
50mm max. from end of weatherboard

Flashing to provide 75mm min. cover

75mm min
behind weatherboards

Building wrap to parapet / balustrade


10

lapped around corner onto wall

10

Wall framing

Building wrap

Cavity batten

10 Abodo WB10 / WB12


weatherboard

8g x 20mm s/s screw


from back of flashing
10

@480 mm crs
75mm min

Abodo AWF2120x120
un-hemmed metal flashing

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Parapet Balustrade Intersection - AW6 Moulding


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.23 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Flexibleflashing tape over


'z' flashing

Cavity closer
35 min

15mm min. drip edge


(Cavity closure to bottom of cladding)
15

5mm min. capillary gap


10
5

35mm 'z' flashing sealed to head angle


Air seal over
15º min. slope
PEF backing rod
35mm min. upstand
10mm min. cover to flange
Building wrap dressed into 0.55mm galv steel head angle
opening with flashing tape seal and rivet to meter box
installed over wrap

Meter box

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Meter Box Head


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.24 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

70x3.2mm annular groove nail


through face of weatherboard

0.55mm galv steel jamb angle


with hem
seal and rivet to meter box
50

Sealant over
Air seal over PEF backing rod
PEF backing rod

Building wrap dressed into


opening with flashing tape
installed over wrap

Meter box

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Meter Box Jamb


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.25 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Building wrap dressed into Meter box


opening with flashing tape
installed over wrap along sill
and 100mm up jamb

Air seal over


PEF backing rod 0.55mm galv steel sill angle
seal and rivet to meter box

35
35mm min. cover to weatherboard

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Meter Box Sill


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.26 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining Wall framing


Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Pipe penetration sealing grommet


100

adhered to building wrap and pipe


Sealant over
Lap 100mm along wall
PEF backing rod Lap 20mm along pipe
Pipe with 5º fall

20

Sealant over PEF backing rod

Packer to suport pipe


Pipe to be secured to packer

Nog

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Pipe Penetration
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.27 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Abodo WB10 / WB12 weatherboard

Cavity batten

Building wrap

Wall framing

2mm expansion gap

Abodo 65mmx7g S.S.


cladding screw or
65x3.15mm annular
groove flat head nail

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Weatherboard Fix - Packer Cavity Batten


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.28 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Abodo WB10 / WB12 weatherboard

Wall framing - single stud

Building wrap

35 scarf joint with construction sealant


eg Sikaflex 11FC and flashing tape backer

Cavity batten

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Weatherboard Join - Vertical


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.29 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap lapped over apron flashing

Cavity batten

Abodo WB10 / WB12 weatherboard


75mm min

Cavity closer

15°
35mm min

110mm minimum upstand


flashing with 10mm hem

Underlay carried up face of


framing behind upstand flashing

Roofing

Stopend

5mm gap max. for


notched downturn

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Apron Flashing
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.30 01
WB10 / WB12
Vertical Weatherboards

Building wrap
Apron flashing

Cavity battens Apron flashing upstand


behind building wrap
Tapered stop-end to Fa and cladding
ll
divert apron flashing
water into gutter

Stop spouting 10mm min.


clear of finished wall cladding
Roofing
10mm
Transition tray flashing
extended to underside
of roofing
Spouting

Eaves and soffit


Fascia

© Abodo Wood Ltd. 2020 SHEET TITLE

Roof Kick-out Flashing Cavity


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. NTS @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.31 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Soffit framing

Soffit lining

AW32 Soffit moulding fitted


tightly up against soffit lining

Continuous horizontal cavity batten


to close off top of wall cavity

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Top Of Wall - Flat Soffit


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.32 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

125
min
eave
flash
ing

Roofing Continuous horizontal cavity batten


to close off top of wall cavity
Roof underlay to
drain into spouting Roofing to overhang
fascia by 50mm
Roof framing 50

35
Spouting

Internal wall lining


Fascia board

Building wrap

Wall framing

Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Top Of Wall - No Soffit


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.33 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Soffit framing

Soffit lining

AW32 Soffit Moulding fitted


tightly up against soffit lining

Continuous horizontal cavity batten


to close off top of wall cavity

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Top Of Wall - Slopping Soffit


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.34 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

in
mm
50m

25° max.

35mm
Soffit lining
Custom metal flashing
under soffit lining and
over cladding 35mm min.

Continuous horizontal cavity batten


to close off top of wall cavity

Internal wall lining

Wall framing

Building wrap
Cavity batten

Abodo WB10 / WB12 weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Top of Wall Raking Soffit


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.35 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing

Flooring

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Flashing tape dressed over


building wrap and framing
Cavity closer
Selected soffit cladding
15

15°

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Soffit Detail
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.36 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing

Flooring

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Flashing tape dressed over


building wrap and framing
Cavity closer
Selected soffit cladding
25

15°

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Alternative Soffit 01
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.37 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Wall framing

Flooring

Building wrap

Cavity batten

Abodo WB10 / WB12 weatherboard

Flashing tape dressed over


building wrap and framing
10

42x14mm Cavity closer. Track


cavity closer @600crs
25

15°
6

Selected soffit cladding

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Alternative Soffit 02
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.38 02
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining


Wall framing

Building wrap

Cavity batten
Abodo WB10 / WB12
weatherboard

Flexible flashing tape over


head flashing
Cavity closure

Stopends to flashing to
finish at back of cladding

15mm min. drip edge


(Cavity closure to bottom
of cladding)
15
5

5mm min. capillary gap

Head flashing
10

15º min. slope


Air seal over 35mm min. upstand
PEF backing rod 10mm min. cover to joinery
Seal head flashing to joinery
for very high wind zones
Packer
Aluminium joinery

Building wrap dressed into


opening with flashing tape
installed over wrap

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Window Head
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.39 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10 / WB12


weatherboard

Vertical timber
cavity batten

70x3.2mm annular groove nail


through face of weatherboard

Line of head flashing over

Foam bond breaker


10

10mm min joinery cover


Air seal over
Building wrap dressed into
PEF backing rod
opening with flashing tape
installed over wrap

Packer Aluminium joinery

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Window Jamb
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.40 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Aluminium joinery

Building wrap dressed into


opening with flashing tape
Air seal over installed over wrap along sill
PEF backing rod and 100mm up jamb

10
Packer

Support bar screwed


to timber framing

Internal wall lining


Cavity batten

Wall framing

Building wrap

Abodo WB10 / WB12


weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Window Sill
CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.41 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Internal wall lining

Wall framing

Building wrap

Cavity batten

Abodo WB10/WB12
weatherboard
vertical cavity batten

Adobo AW91 batten

70x3.2mm annular groove nail


through face of weatherboard

Line of head flashing over

Foam bond breaker


10

10mm min joinery cover


Air seal over
Building wrap dressed into
PEF backing rod
opening with flashing tape
installed over wrap
Packer
Aluminium joinery

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Window Jamb - AW91 batten


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.42 01
1. Weatherboards must be coated with at least one coat all sides prior to fixing.

2. Fixing points must be pre-drilled minimum 1mm smaller than the fastener.

3. Cut ends and exposed timber must be sealed with an approved coating or end seal.

Aluminium joinery

Building wrap dressed into


opening with flashing tape
Air seal over installed over wrap along sill
PEF backing rod and 100mm up jamb

10
Adobo AW91 batten in-fill fixed
Packer
horizontally between vertical battens
Support bar screwed
to timber framing

Internal wall lining

Vertical cavity
batten

Wall framing

Building wrap

Abodo WB10/WB12
weatherboard

scale in millimetres

0 20 40 60 80 100

© Abodo Wood Ltd. 2020 SHEET TITLE

Window Sill - AW91 batten


CM70046

info@abodo.co.nz
T +64 (9) 249 0100
SCALE: SHEET NUMBER REVISION
PROFILE
Abodo Wood Ltd. 1:2 @ A4
62 Ascot Road, Mangere,
Auckland 2022, New Zealand
Vulcan WB10 / WB12 Vertical Weatherboard PRINT
DATE: 01/04/2020
H.V.43 01