SUBMITTAL AM504JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
System Specifications
Module 1 AM168HXVAFH2AA
Modules
System Module 2 AM168HXVAFH2AA
Connected
Module 3 AM168HXVAFH2AA

US Ton (nominal) 42
Nominal / Rated Cooling1 504,000 / 480,000
Capacity (Btu/h)
Nominal / Rated Heating1 567,000 / 536,000
Performance
EER Ducted / Non-Ducted 9.50 / 9.50
IEER Ducted / Non-Ducted 15.50 / 16.00
High Heat COP Ducted / Non-Ducted 3.20 / 3.20

Voltage (ø/V/Hz) 3 / 208-230 / 60 Compatibility


Power Maximum Circuit Breaker (MCCB/ELB/ELCB) 80.0 + 80.0 + 80.0 Only compatible with Samsung DVM S indoor units (AM****N**CH**), AHU kits (MXD-K***AN),
and UCK (MCM-D211UN).
Minimum Circuit Ampacity (MCA) 66.0 + 66.0 + 66.0

Total Capacity (%) Construction


50 - 130% Of Outdoor Unit Capacity
Indoor Units The unit shall be galvanized steel with a baked on powder coated finish.
Maximum Indoor Unit Quantity 64
Heat Exchanger
Refrigerant R410A Factory Charge (lbs.) 72.75
The heat exchanger shall be mechanically bonded fin to copper tube.
Pipe Connections Liquid X Suction (inches) 3/4 X 1 5/8
The aluminum fins of the heat exchanger shall have a protective coating.
Max. Distance - ODU to IDU (feet) 656 (722 equivalent)
Installation Vertical Separation ODU to IDU 3 361 Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Limitation2 (feet) corrosion development to 2,280 hours.
Highest/Lowest IDU 164
Total Refrigerant Pipe (feet) 3,280 Controls
The unit shall be operated via NASA Protocol with controls provided by Samsung
Sound Level dB (A) Max. 68

Cooling The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Operating °F 23 - 120 (-13 - 120 with LACH guards 4)
information, system settings, system tag/name, and other information.
Temperatures Heating °F -13 - 75

Safety Certifications Controls shall integrate with a BMS system without additional interface modules
ETL (UL 1995)
Control wiring shall be 16 AWG X 2 shielded wire.
Intelligent logic to ensure proper operation within unit design limitations and
operational parameters. Refrigerant System
High pressure sensor, low pressure sensor, over-voltage protection, compressor The compressors shall be Samsung hermetically sealed, inverter driven, direct flash injected, DC
over- current protection, current transformer, fan motor voltage protection, fan motor scroll type with soft-start capability.
Protection Devices
thermal protection, overheat protection, phase detection protection, high voltage
fuses Flash injected compressors provide advanced low ambient heating performance.

Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe Refrigerant flow shall be controlled by EEV (electronic expansion valve) throughout the system.
operating temperatures.
Subcooling devices in system maintain capacity at extreme system refrigerant pipe lengths and
Accessories
minimize refrigerant noise.
Qty. Model Number Description
1 MXJ-TA3819M Outdoor unit tee (liquid and suction fittings, ≤ 461,000 Btu/h ) Other Features
1 Outdoor unit tee (liquid and suction fittings, ≥ 478,400 Btu/h)
Asymmetrical scroll design with rotating compressor operation/priority (where applicable).
MXJ-TA4422M

WHG-T2 Top wind/hail guard (8 - 18 ton outdoor units) Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum duration
in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered oil recovery cycles).
WHG-SL Left side wind/hail guard (6 - 16 ton outdoor units)
Oil recovery operation shall not interrupt heating or cooling operation.
WHG-SR Right side wind/hail guard (6 - 16 ton outdoor units)
Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic activation or
WHG-R2 Rear wind/hail guard (8 - 16 ton outdoor units) manual activation (with MIM-B14).

LACH-2-KIT Low ambient cooling hood and side guards (large chassis, 3 required) Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by monitoring air
resistance across the condenser coil during heating operation to determine defrost operation
LACH-2-SIDE KIT Low ambient cooling side guards (8 - 16 ton outdoor units)
initiation to prevent unnecessary defrost cycles.
MCM-C200U Heat pump mode selector switch
Optional snow blowing logic to prevent snow accumulation on idle outdoor units
External contact control interface module (operation and error output,
MIM-B14 Continuous operation while outdoor unit(s) change between heating and cooling modes (conditions
night silent mode manual activation)
apply).
1 Certified in accordance with the AHRI Variable Refrigerant Flow Multi-Split Air-Conditioners and Heat Pump (VRF) Certification
Program which is based on the latest edition of AHRI Standard 1230.
Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable
2 Other pipe restrictions and requirements exist. Please consult technical data book or installation manuals for full details regarding
at outdoor unit or central control devices: DMS 2 (MIM-D00AN), DMS 2.5 (MIM-D01AUN), BACnet
limitations and other requirements for vertical separation over 163 feet (outdoor to lowest indoor).
Gateway (MIM-B17N, MIM-B17BUN), LON Gateway (MIM-B18N, MIM-B18BUN).
3 When outdoor unit is lower than indoor units, and vertical separation is greater than 131 feet, additional conditions apply. Please
refer to supporting documents at www.SamsungHVAC.com
Energy savings options to reduce system energy consumption when average indoor room
4 When operating in cooling mode between -13°F and 5°F OA, LACH-2-KIT is required. When operating in cooling mode between 5°F
temperatures are greater than average indoor set temperatures in heating mode or when average
and 23°F OA, LACH-2-SIDE KIT is required. Refer to technical bulletin at www.DVMdownload.com for full details and requirements.
indoor room temperatures are lower than average indoor set temperatures in cooling mode.

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

© 2019 Samsung HVAC Variable Refrigerant Flow (VRF) Multi-Split AC and HP


AHRI Standard 1230
SHA-DVMS-03122019 www.SamsungHVAC.com
2 of 3 Page
SUBMITTAL AM504JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit

Module Specifications
Module Model Number AM168HXVAFH2AA AM168HXVAFH2AA AM168HXVAFH2AA

US Ton (nominal) 14 14 14
Nominal / Rated Cooling1 168,000 / 160,000 168,000 / 160,000 168,000 / 160,000
Performance Capacity (Btu/h)
Nominal / Rated Heating1 189,000 / 180,000 189,000 / 180,000 189,000 / 180,000
Compressor Modulation Down to Btu/h 7,513 7,513 7,513

Voltage (ø/V/Hz) 3 / 208-230 / 60 3 / 208-230 / 60 3 / 208-230 / 60


Maximum Circuit Breaker (MCCB/ELB/ELCB) 80 80 80
Power
Minimum Circuit Ampacity (MCA) 66 66 66
SCCR kA 5 5 5

Type SSC Scroll X 2 SSC Scroll X 2 SSC Scroll X 2


Compressor
RLA A 24.0 24.0 24.0

Refrigerant R410A Factory Charge lbs. 24.25 24.25 24.25

Pipe Connections Liquid X Suction (inches) inches 5/8 X 1 1/8 5/8 X 1 1/8 5/8 X 1 1/8

Type Propeller Propeller Propeller


Fan
Output (CFM) 10,948 10,948 10,948
Type DC DC DC
Condenser Fan
Motor Output (W) 620 X 2 620 X 2 620 X 2
FLA (A) 3.0 3.0 3.0
Max. External Static Pressure "WC 0.31 0.31 0.31

WXHXD Inches 51 X 66 3/4 X 30 1/8 51 X 66 3/4 X 30 1/8 51 X 66 3/4 X 30 1/8


Dimensions Weight lbs. 707.70 707.70 707.70
Shipping Weight lbs. 745.2 745.2 745.2
Sound Level dB (A) Max. 63 63 63
1Certified in accordance with the AHRI Variable Refrigerant Flow Multi-Split Air-Conditioners and Heat Pump (VRF) Certification
Program which is based on the latest edition of AHRI Standard 1230.

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

www.SamsungHVAC.com
Page 3 of 3
SUBMITTAL AM504JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
AM168HXVAFH2AA Dimensional Drawing

51"

30 1/8"
1 7/16"
66 3/4"




26 13/32"


24 1/4"

21 15/16"


19 3/8"
4 13/16"


9 1/2"

6 3/4"
4 1/4"
LEFT SIDE RIGHT SIDE
2"

7 15/16"
 
45 1/4"


22 5/8"
29 31/32"

31 5/8"

51"
 BOTTOM

1 Gas refrigerant pipe opening 5 Power conduit opening (4 X Ø1 3/4")


2 Liquid refrigerant pipe opening 6 Communication conduit opening (8 X Ø7/8")
3 Power conduit opening (2 X Ø1 3/4") 7 Knock-out opening for refrigerant piping (7" X 3")
4 Communication conduit opening (2 X Ø1 3/8") 8 Anchor bolt hole (4 X Ø15/32")

888-699-6067
www.SamsungHVAC.com