SUBMITTAL AM480JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
System Specifications
Module 1 AM144FXVAFH2AA
Modules
System Module 2 AM168HXVAFH2AA
Connected
Module 3 AM168HXVAFH2AA
US Ton (nominal) 40
Nominal / Rated Cooling1 480,000 / 456,000
Capacity (Btu/h)
Nominal / Rated Heating1 540,000 / 510,000
Performance
EER Ducted / Non-Ducted 9.50 / 9.50
IEER Ducted / Non-Ducted 15.70 / 16.20
High Heat COP Ducted / Non-Ducted 3.20 / 3.20
Max. Distance - ODU to IDU (feet) 656 (722 equivalent) The aluminum fins of the heat exchanger shall have a protective coating.
Safety Certifications ETL (UL 1995) Controls shall integrate with a BMS system without additional interface modules
Intelligent logic to ensure proper operation within unit design limitations and Control wiring shall be 16 AWG X 2 shielded wire.
operational parameters.
High pressure sensor, low pressure sensor, over-voltage protection, compressor Refrigerant System
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash injected, DC
over- current protection, current transformer, fan motor voltage protection, fan motor
Protection Devices scroll type with soft-start capability.
thermal protection, overheat protection, phase detection protection, high voltage
fuses
Flash injected compressors provide advanced low ambient heating performance.
Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe
operating temperatures. Refrigerant flow shall be controlled by EEV (electronic expansion valve) throughout the system.
Accessories
Subcooling devices in system maintain capacity at extreme system refrigerant pipe lengths and
Qty. Model Number Description minimize refrigerant noise.
1 MXJ-TA3819M Outdoor unit tee (liquid and suction fittings, ≤ 461,000 Btu/h )
Other Features
1 MXJ-TA4422M Outdoor unit tee (liquid and suction fittings, ≥ 478,400 Btu/h) Asymmetrical scroll design with rotating compressor operation/priority (where applicable).
WHG-T2 Top wind/hail guard (8 - 18 ton outdoor units)
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum duration
WHG-SL Left side wind/hail guard (6 - 16 ton outdoor units) in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered oil recovery cycles).
Oil recovery operation shall not interrupt heating or cooling operation.
WHG-SR Right side wind/hail guard (6 - 16 ton outdoor units)
WHG-R2 Rear wind/hail guard (8 - 16 ton outdoor units) Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic activation or
manual activation (with MIM-B14).
LACH-2-KIT Low ambient cooling hood and side guards (large chassis, 3 required)
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by monitoring air
LACH-2-SIDE KIT Low ambient cooling side guards (8 - 16 ton outdoor units) resistance across the condenser coil during heating operation to determine defrost operation
initiation to prevent unnecessary defrost cycles.
MCM-C200U Heat pump mode selector switch
Optional snow blowing logic to prevent snow accumulation on idle outdoor units
External contact control interface module (operation and error output,
MIM-B14
night silent mode manual activation)
Continuous operation while outdoor unit(s) change between heating and cooling modes (conditions
1 Certified in accordance with the AHRI Variable Refrigerant Flow Multi-Split Air-Conditioners and Heat Pump (VRF) Certification apply).
Program which is based on the latest edition of AHRI Standard 1230.
2 Other pipe restrictions and requirements exist. Please consult technical data book or installation manuals for full details regarding Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable
limitations and other requirements for vertical separation over 163 feet (outdoor to lowest indoor). at outdoor unit or central control devices: DMS 2 (MIM-D00AN), DMS 2.5 (MIM-D01AUN), BACnet
3 When outdoor unit is lower than indoor units, and vertical separation is greater than 131 feet, additional conditions apply. Please Gateway (MIM-B17N, MIM-B17BUN), LON Gateway (MIM-B18N, MIM-B18BUN).
refer to supporting documents at www.SamsungHVAC.com
4 When operating in cooling mode between -13°F and 5°F OA, LACH-2-KIT is required. When operating in cooling mode between 5°F Energy savings options to reduce system energy consumption when average indoor room
and 23°F OA, LACH-2-SIDE KIT is required. Refer to technical bulletin at www.DVMdownload.com for full details and requirements. temperatures are greater than average indoor set temperatures in heating mode or when average
indoor room temperatures are lower than average indoor set temperatures in cooling mode.
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
AHRI Standard 1230
SHA-DVMS-03122019
2 of 3 Page
SUBMITTAL AM480JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
Module Specifications
Module Model Number AM144FXVAFH2AA AM168HXVAFH2AA AM168HXVAFH2AA
US Ton (nominal) 12 14 14
Nominal / Rated Cooling1 144,000 / 138,000 168,000 / 160,000 168,000 / 160,000
Performance Capacity (Btu/h)
Nominal / Rated Heating1 162,000 / 154,000 189,000 / 180,000 189,000 / 180,000
Compressor Modulation Down to Btu/h 7,513 7,513 7,513
Pipe Connections Liquid X Suction (inches) inches 1/2 X 1 1/8 5/8 X 1 1/8 5/8 X 1 1/8
Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
www.SamsungHVAC.com
3 of 3 Page
SUBMITTAL AM480JXVAFH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
AM144FXVAFH2AA, AM168HXVAFH2AA Dimensional Drawing
51"
30 1/8"
1 7/16"
66 3/4"
26 13/32"
24 1/4"
21 15/16"
19 3/8"
4 13/16"
9 1/2"
6 3/4"
4 1/4"
LEFT SIDE RIGHT SIDE
2"
7 15/16"
45 1/4"
22 5/8"
29 31/32"
31 5/8"
51"
BOTTOM