Professional Documents
Culture Documents
BX Series: Terminal Type and Long Sensing Distance Type
BX Series: Terminal Type and Long Sensing Distance Type
BX Series: Terminal Type and Long Sensing Distance Type
(MS-2) (MS-4)
Please read “Caution for your safety” in operation
manual before using. ※MS-4 is sold separately.
(MS-3)
Specifications
Free power type, Relay contact output type
Standard type BX15M-TFR BX5M-MFR BX3M-PFR BX700-DFR
Model
With Timer BX15M-TFR-T BX5M-MFR-T BX3M-PFR-T BX700-DFR-T
Retroreflective Retroreflective
Sensing type Through-beam Diffuse reflective
(Standard type) (Built-in polarizing filter)
※1 ※2 ※3
Sensing distance 15m 0.1 to 5m(MS-2) 0.1 to 3m(MS-3) 700mm
Opaque materials of Translucent,
Sensing target Opaque materials of Min. ø60mm
Min. ø15mm opaque material
Max. 20% at rated setting
Hysteresis - distance
Response time Max. 20ms
Power supply 24-240VAC ±10% 50/60Hz, 24-240VDC ±10%(Ripple P-P:Max. 10%)
Power consumption Max. 3VA
Light source Infrared LED(850nm) Red LED(660nm) Infrared LED(940nm)
Sensitivity adjustment Built-in the adjustment VR
Operation mode Selectable Light ON or Dark ON by switch
※4
Control output Relay contact output(Contact capacity : 30VDC 3A, 250VAC 3A at resistive load, Contact composition: 1c)
Relay life cycle Mechanically : Min. 50,000,000, Electrically : Min. 100,000
Self-diagnosis output Green LED turns on at stable operation
Timer function Selectable ON Delay, OFF Delay, One Shot Delay by slide switch [Delay Time : 0.1 to 5sec.(Adjustable VR)]
Indicator Operation indicator : yellow LED, Self-diagnosis indicator : green LED
Insulation resistance Min. 20MΩ(at 500VDC megger)
Insulation type Double or strong insulation(Mark: , Dielectric voltage between the measured input and the power: 1.5kV)
Noise resistance ±1,000V the square wave noise(pulse width : 1㎲) by the noise simulator
Dielectric strength 1500VAC 50/60Hz for 1minute
Mechanical 1.5mm amplitude or 300m/s2 at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Vibration
Malfunction 1.5mm amplitude or 300m/s2 at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes
Mechanical 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Shock
Malfunction 100m/s²(approx. 10G) in each of X, Y, Z directions for 3 times
Ambient illumination Sunlight : Max. 11,000㏓, Incandescent lamp : Max. 3,000㏓ (Receiver illumination)
Environment
A-50
Long Sensing, Amplifier Built-in type with Universal voltage (terminal)
Specifications (A)
Photo
electric
(B)
Fiber
Standard type BX15M-TDT BX5M-MDT BX3M-PDT BX700-DDT optic
Model sensor
With Timer BX15M-TDT-T BX5M-MDT-T BX3M-PDT-T BX700-DDT-T
(C)
Retroreflective Retroreflective Door/Area
Sensing type Through-beam Diffuse reflective
(Standard type) (Built-in polarizing filter) sensor
※1 ※2 ※3
Sensing distance 15m 0.1 to 5m(MS-2) 0.1 to 3m(MS-3) 700mm
(D)
Proximity
Opaque materials of Translucent, sensor
Sensing target Opaque materials of Min. ø60mm
Min. ø15mm opaque material
Max. 20% at rated setting (E)
Hysteresis - distance Pressure
sensor
Timer function Selectable ON Delay, OFF Delay, One Shot Delay by slide switch [Delay Time : 0.1 to 5sec.(Adjustable VR)]
(K)
Indicator Operation indicator : yellow LED, Self-diagnosis indicator : green LED Timer
(P)
Ambient temperature -20 to 55℃, storage : -25 to 70℃ Switching
mode power
supply
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
(Q)
Protection IP66(IEC standard) Stepper
motor&
Driver&Controller
Material Case, Lens cover: PC, Sensing part: Acrylic
(R)
Individual - Mirror(MS-2) Mirror(MS-3) - Graphic/
Logic
Accessory panel
Common VR adjustment driver, Mounting bracket, Bolts, Nuts
(S)
Field
Approval network
device
TDT: Approx. 211g MDT: Approx. 123g PDT: Approx. 141g DDT: Approx. 116g
Unit weight TDT-T: Approx. 212g MDT-T: Approx. 124g PDT-T: Approx. 142g DDT-T: Approx. 117g
(T)
Software
※1: It is same when using the MS-4 reflector (sold separately). The sensor can detect under 0.1m.
※2: When using the MS-2 reflector, the sensing distance is 0.1 to 2m. The sensor can detect under 0.1m.
※3: It is for Non-glossy white paper(200×200mm) (U)
※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment. Other
A-51
BX Series
Feature data
Through-beam type Diffuse reflective type
● BX15M-TFR / BX15M-TFR-T ● BX700-DFR / BX700-DFR-T
● BX15M-TDT / BX15M-TDT-T ● BX700-DDT / BX700-DDT-T
Parallel shifting characteristic Angle Characteristic Sensing area
Measuring Measuring Measuring
Data Data method Data
method method
Standard sensing
Receiver Receiver target: non-glossy
white paper 900
15 200×200mm
Retroreflective type
● BX5M-MFR / BX5M-MFR-T ● BX5M-MDT / BX5M-MDT-T
Parallel shifting characteristic Angle Characteristic Reflector angle characteristic
Measuring Measuring Measuring
Data Data Data
method method method
Reflector Reflector Reflector
(MS-2) (MS-2) (MS-2)
5
Sensing distance L (m)
3
Sensing distance L (m)
ℓ1 L
2 L θ L 2
θ 2
1
1 1
0
90 60 30 0 30 60 90 0 0 40° 30° 20°10° 0 10° 20° 30°40°
ℓ1 ℓ1 6° 4° 2° 0 2° 4° 6°
Retroreflective Retroreflective Left Center Right Retroreflective Left Center Right
type(Built- Left Center Right
type(Built- type(Built-
in polarizing Operation angle θ Operation angle θ
Sensing area(mm) in polarizing in polarizing
filter) filter) filter)
A-52
Long Sensing, Amplifier Built-in type with Universal voltage (terminal)
(C)
Universal + Door/Area
24-240VAC±10% Overcurrent
power Power
protection
sensor
circuit - 24-240VDC±10% Max. 200mA Load
Load
Main circuit
Main circuit
(D)
Proximity
+ 12-24VDC sensor
N.O. Max. 50mA
OUT ±10%
250VAC 3A -
N.C. (E)
30VDC 3A
Overcurrent Load Max. 200mA Pressure
COM sensor
protection
Output relay (F)
Rotary
※In case of product with the output protection device, if terminals of control output are short-circuited or overcurrent condition exists, the control encoder
(I)
SSR/
Incident Power
Unstable operation area light controller
level
Operation
level (J)
Counter
ON
Light ON T
(T)
OFF Software
ON Delay OFF ON
ON
Dark ON T T T
OFF (U)
Other
ON
Light ON T T T
OFF
OFF Delay OFF OFF
ON
Dark ON T
OFF
※T : Time set by the timer adjustment VR.
※Conversion to another mode of timer modes is applied after a former mode is finished.
A-53
BX Series
Connections
Through-beam type
● BX15M-TFR1 ● BX15M-TFR2 ● BX15M-TDT1 ● BX15M-TDT2
BX15M-TFR2-T BX15M-TDT2-T
Power COM Power
N.C(Not connected) N.C(Not connected)
24-240VAC 24-240VAC OUT2(PNP)
24-240VDC 24-240VDC 12-24VDC 12-24VDC
Sensing Sensing
target target OUT1(NPN) STAB(NPN)
N.C N.O. N.C. N.C
(Not connected) (Not connected)
OUT2(PNP)
COM
COM OUT2(PNP)
Max. 7
Min. 3.6
Max. 7
Max. 7
45
50
Max. 19 Max. 19
60
Waterproof
Washer rubber
A-54
Long Sensing, Amplifier Built-in type with Universal voltage (terminal)
(C)
[Emitter] [Receiver]
Door/Area
sensor
(D)
Sensitivity adjustment VR Operation indicator Self-diagnosis indicator Terminal No. Proximity
(yellow) (green) sensor
(E)
Retroreflective type(Standard type, Diffuse reflective type Pressure
sensor
Built-in polarizing filter)
Self-diagnosis indicator(green) Self-diagnosis indicator(green) (F)
Operation indicator(yellow) Operation indicator Rotary
Terminal No. (yellow) encoder
Terminal No.
(G)
Connector/
Socket
(H)
Timer mode selection switch Temp.
Timer mode Timer adjustment VR controller
Timer adjustment VR selection switch
Dark ON / Light ON Sensitivity adjustment VR
selection switch Sensitivity adjustment VR Dark ON / Light ON (I)
selection switch SSR/
Power
controller
※There are no Timer mode selection switch and the timer adjustment VR in type without Timer function.
(J)
Counter
(L)
Panel
meter
25.5
45
(M)
80 Tacho/
Speed/ Pulse
meter
6.5 M4 Bolt
25 50.5 (N)
Display
Optical unit
axis 80
25
(O)
Sensor
Optical axis controller
68
(P)
Switching
31.5
mode power
supply
76
Hexagonal nut
5
(R)
Graphic/
Logic
panel
(T)
3-4.2 Software
16
38
2-ø3.2
60.5
38.5
60.5
52
52
(U)
Other
50.5 2
2.8
20
38.5 7
6.8 2.5 2.5 29.3
34 2-ø3.8 34 40.8 3.4
8.5 8.5
40.5 81.6
20
1.6
13
6.8
A-55
BX Series
xis
1. The sensitivity should be adjusted depending on a cal a
Opti
sensing target or mounting place.
2. Set the target at a position to be detected by the beam, Photoelectric Adjust Up/Down
then turn the adjustment VR until position ⓐ where the sensor
operation indicator(yellow LED) turns ON and the self-
diagnosis indicator(green LED) turns OFF from min. 30° to 45°
position of the adjustment VR.
3. Take the target out of the sensing area, then turn the
adjustment VR until position ⓑ where the the operation L
indicator (yellow LED) turns OFF and the self-diagnosis Reflector
Sensing (MS-2)
indicator(green LED) turns ON. If the indicators do not target
operate, max. position is ⓑ.
4. Set the adjustment VR at the center of two switching ※If the mounting place is too narrow,
position ⓐ, ⓑ. please use MS-4 instead of MS-2.
※Above sensitivity adjustment is for Light ON mode. If it
is for Dark ON mode, operation indicator(yellow LED)
operates opposite. <MS-4>
※The sensing distance indicated on specification chart is
for 200×200mm of non-glossy white paper. Be sure that Retroreflective type(Built-in polarizing filter)
it can be different by size, surface and gloss of target. The light passed through the polarizing filter of the emitter
reaches to the MS-3 reflector converting as horizontal
direction. It reaches to the receiver element of polarizing
Sensing filter converting as vertical by the MS-3 reflector. Therefore,
target this type can also detect reflective mirror.
Vertical direction
Optimal polarizing filter
ⓐ position
Receiver
ⓑ
Photoelectric
sensor MS-3
MIN MAX
Emitter
Horizontal direction
polarizingfilter
A-56