Substandard Failure of
Air Compressors are
equipment Equipment,
procured from reputed 1 4 L
Bursting of P&M Eng.
vendors with IS make
Container
Unguarded workmen P&M Eng.
All rotating parts are 1 3 L
rotating parts Entanglem
guarded
ent
Poor Condition Workmen/ Site
of Hose Bursting of Engineer Reinforced hoses are Eng./P&M
2 4 M Whip arrestor should be Eng.
Hose/ used.
Hitting the Couplers are used to join installed in all L
compressors.
workmen the hoses.
Outlet pressure is
4 Compressor controlled by quick shut
operation valves.
Site Eng.
Excessive Bursting of Workmen/ Pressure Gauges &
pressure Cylinders Engineer Pressure relief valves are 1 4
fitted & Ensured working L
condition.
Regular draining of drain
valves to avoid corrosion
& Condensation of water.