Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HTO, Heat Exchange Equipments - MCQ

Q. A B C
Question D
No
1 Which of the following is NOT a Recuperator Regenerator Mixer
none of the above
type of heat exchanger?
2 Large sized and heavy shell-and-tube automotive aircraft marine none of the above
heat exchangers are suitable for applications applications applications
3 Maximum effectiveness of a counter 0.5 0.75 0.80 1
flow heat exchanger could be
4 In an extended surface heat Flows outside Flows inside the Flows outside Does not flow
exchanger, fluid having lower the tubes tubes and inside the
coefficient tubes
5 The energy transfer between the hot Direct contact Regenerators Recuperators Boilers
fluid and cold fluids is brought about heat exchanger
by their complete physical mixing in
6 In a double pipe heat exchanger, in 60.7℃ 66.7℃ 76.7℃ 86.7℃
the inner side fluid enters at 20℃
and leaves at 45℃. The annulus has
steam condensing at 1atm. What is
the value of LMTD?
7 Compact heat exchangers have small surface large surface large surface large surface area
area per unit volume area per unit
volume volume
8 For the same heat transfer Q and less than LMTD equal to LMTD LMTD for more than LMTD
same overall heat transfer coefficient for counter flow for counter flow counter flow for counter flow
Uo, surface area required for parallel
flow operation is always
9 For the same inlet and exit less than LMTD greater than equal to LMTD greater than
temperatures of two fluids, the for parallel flow LMTD for for parallel flow LMTD for cross
LMTD for counterblow is always parallel flow flow
10 Heat exchanger tubes are never made Steel Iron copper Lead
of_________________ material
11 In parallel flow heat exchangers, the exit the exit the exit the exit
temperature of temperature of temperature of temperature of
hot fluid is hot fluid is hot fluid is cold fluid is
always less than always equal to always more always more than
the exit the exit than the exit the exit
temperature of temperature of temperature of temperature of
cold fluid cold fluid cold fluid cold fluid
12 The compact heat exchangers are Chemical Sugar industries both a. and b. none of the above.
commonly used in industries
13 The heat exchanger is said to be more than 700 more than 100 more than 200 more than 300 m2/
compact when its area density is m2/ m3 m2/ m3 2
m/m 3
m3
14 The scales form in heat exchangers Extra factor Minimum factor Maximum factor fouling factor
after a period of operation and
provide additional resistance to heat
transfer with some heat transfer
coefficient. The reciprocal of this
scale heat transfer coefficient is
called as
15 Which of the following temperature Mean Logarithmic Logarithmic Temperature
difference is safer than other to Temperature Mean Mean Difference
consider in designing of heat Difference Temperature Temperature
exchangers? Difference
(LMTD)
16 Baffles in shell and tube heat Create Increase heat both A and B Decrease heat
exchanger helps to Turbulence transfer rates. transfer rates
17 center to center distance between ditch length height pitch
two tubes in tube sheet is called
18 Distance between adjacent tubes in clearance ditch length height
shell and tube heat exchanger is
called
19 Double pipe heat exchanger requires small floor large floor space no floor space large space
comparatively space
20 Fins helps to decrease the increase the area increase the Drop in heat
area of heat of heat transfer length of heat transfer
transfer transfer
21 Fluid flowing through tubes in shell shell side fluid exchanger side heat side fluid tube side fluid
and tube heat exchanger is called fluid
22 For heat transfer to take place both fluids should
between two fluids be at different
temperatures
23 Fouling factor is used in heat exchanger
design as a safety
factor
24 Graphite used for graphite block heat All of the above
exchanger has
25 Heat exchange equipment used to condenser
condense a vapor is called
26 Heat exchange equipment used to cooler
cool process fluid by water or air is
called
27 Heat exchange equipment used to reboiler
meet latent heat requirements at the
bottom of distillation column is
called
28 Heat exchanger employed for the boiler condenser reboiler Evaporator
concentration of solution by
evaporating water is called
29 Heat exchanger generally used for Scrapped Plate heat Pipe heat Shellheat
solid liquid suspension, viscous surface heat exchanger exchanger exchanger
solutions, wax plant etc. is exchanger
30 Heat exchanger well suited for Graphite block
handling corrosive fluids is
31 In a shell and tube heat exchanger, Concurrent/
the heat transfer area is maximum Parallel
for ________
32 In case of heat exchanger, the value as large as
of LMTD should be possible
33 In case of multipass shell and tube and the wall are
heat exchanger the temperature drop proportional to
in fluid individual
resistances
34 In counter flow compared to parallel Both A. and B.
flow,
35 In double pipe heat exchanger the annular space
space between inner pipe and outer
pipe is called
36 Kettle reboiler generally incorporates Floating head
a ------------- head arrangement.
37 Large sized and heavy shell-and-tube none of the above
heat exchangers are suitable for
38 Maximum effectiveness of a parallel 0.5
flow heat exchanger could be
39 Metallic pieces attached to heat fins
transfer surface are called
40 Multipass heat exchangers are used obtain a high obtain a low obtain a less reduce heat
to heat transfer heat transfer heat transfer transfer
coefficient coefficient coefficient coefficient
41 Temperature profile in steady state Linear
heat transfer of heat exchanger is
42 The equipment used to impart heater
sensible heat to process fluid is
called
43 The heat exchanger consisting of Double pipe
two concentric pipes is called --------
---- heat exchanger
44 The name 2-4 Shell and Tube Heat Partition of the
Exchanger informs that Shell into two and
four passes of the
tube
45 The ratio of actual heat transfer to effectiveness of
the maximum possible heat transfer heat exchanger
is called
46 The requirement of transfer of a having multiple
large heat is usually met by tube or shell
passes
47 The shell of a tubular heat exchanger account for the
is provided with expansion bellows uneven expansion
to of shell and tube
bundles
48 The simplest type of heat exchanger Shell and tube graphite block double pipe plate type
used in industries is
49 To hold the baffles in place ----------- Tie rods
- are used.
50 Tube pitch is the _____________ of Sum
tube diameters and the clearances.
51 What can we infer from the name 1- One Shell and
4 Shell and Tube Heat Exchanger? Four pass of the
tube
52 What is the number of baffles in the 14
shell side if the baffle spacing is 6cm
and Length of the setup is 90cm?
53 When both fluids flow in same Parallel
direction in heat exchanger then the
flow is called
54 When the direction of flow is axial Longitudinal cross tilted
parallel to the axis of flow ----------
fins are used
55 When two fluids flow at right angles cross tilted Longitudinal axial
to each other in heat exchanger the
flow is known as
56 Which of the following has the Counter-flow
maximum Log mean temperature
difference for a Double Pipe Heat
Exchanger?
57 Which of the following is not a Plate parallel countercurrent Cross flow Agitated
– Type heat exchanger?
58 Which side is suitable to provide fins Liquid side Both sides Gas side None
on to enhance heat transfer, when
heat exchanges between gas and
liquid?
59 Choose the correct statement with both the fluids at
respect to a counter-flow heat the inlet are in thei
exchanger state
60 Capacity ratio is defined as the Mass and Mass and Specific heat Time and
product of temperature specific heat and temperature temperature

You might also like