Professional Documents
Culture Documents
KDL16 Drive - Quick Setup Guide
KDL16 Drive - Quick Setup Guide
1085740.wmf
Purpose of this document is to give basic instructions for setting parameters for the KDL16 drive during
installation phase with LCE electrification.
Refer to the elevator level instructions for the commissioning prerequisites, safety chain checking, setting
the non-drive features, special features, swapping motor phases and especially for the working safety.
This instruction is used in accordance with several elevator configurations. You must read the safety
instructions in each elevator level installation manual to ensure your working safety.
Tip 1: LWD: Load weighing device setting on KDL16 (Note! LWD Display (5_1) shows 50% until 6_74 = -2)
Tip 2: Encoder polarity can be checked from speed display while moving the car with manual or electrical brake
release device.
* **
1090787.pdf
KONE MaxiSpace™:
WARNING! The speed can increase fast when you open the brake. When the traction sheave starts
moving, stop it by letting the brakes close every 0.5 – 1.0 second in order to prevent the elevator from
accelerating to over speed. The car will move down (let it move max. 0.5 m).
Look at the speed display:
o If the speed is negative (for example, -0.08), then encoder polarity is correct.
o If the speed is positive (for example, 0.08), then encoder polarity is NOT correct.
Correct polarity on GMX: Set 6_65 from 1 -1 (or -1 1)