INPUT DATA

ALL DIMENSIONS IN (mm) UNO T= 1200

F'C= 35 Mpa e
d= 2.25 inch anchor dia
PHIc= 0.65
R= 1
Dp 70 mm head of anchor y2
t= 50 mm thichness of plate added at head b

Check concete break out


E y1
Npr= 8 Abh. PHIc. F'c R D-16,D-15, D.6.3.6

Abh=2ax2a-phi*d^2/4= 59936.09 mm2

Npr= 10908.3690784 kn
2a= 250

METHOD-1
CHECK END PLATE
AREA= 59936.0938375 MM2
T= 1200 KN
ST= 20.0213247672 NT/MM2 T= 1200 kn
Lc= 90 mm
Mf= 81086.3653073 nt.mm
fyplate= 300 Mpa
z=bt^2/4= 300.319871509 mm3
34.6594790214 mm fm
f1
METHOD-2
fy bolt= 896 Mpa
2a
T=(A/3-PHI.d2/4)*f
fm= 65.6835044021 Nt/mm2 a-d/2= 96.425 mm
f1=(a-d/2)/a*fm= 50.66826 Nt/mm2

Mf= 78517.053732 nt.mm Mf=(a-d/2).f1(a-d/2)/6


fyplate= 300 Mpa
z=bt^2/4= 290.803902711 mm3
t= 34.1059468545 mm

D.6. DESIGN REQUIREMENT FOR TENSILE LOADING/ CONCRETE DESIGN HANDBOOK THIRD EDITION
D.6.1.2
R= 1 choose R from the table D.5.4
n= 1
Ase=0.7 Ag= 1794.734 mm2
PHIs= 0.85
PHIc= 0.65
fut=min(1.9 FY, 860Mpa)= 860 Mpa TABLE D.5.4.
Nst=n.Ase.PHIs.fut.R= 1312 Kn ok D-3 R CONDITION
0.8 tension/ductile steel
D.6.2 CONCRETE BREAKOUT RESISTANCE AT ANCHOR IN TENSION 0.7 tension/brittle steel
1.15 tension case 'A'
Ncbr=An/Ano(Psied,n. Psic,n.Psicp,n). Nbr= 1 tension case 'B'

C1= 440 mm C2= 747 mm S1= 781 mm


C1,C2 min. edge distance
S1= c/c of anchor
Cmax= 747 < 1.5.hef= 2032.5

hemb= 1355 mm embedment length of anchor C1/1.5=


hef=min(hemb, max(C1/1.5,C2/1.5,S1/3,S2/3)= 498 mm C2/1.5=
max(C1/1.5,C2/1.5,S1/3,S2/3)= 498 mm choose max from tablS1/3=
S2/3=
hef= 498 mm 275< hef= 498 <625
D.6.2.1
Ano=9. hef^2= 2232036 mm2 D-6 k
Nbr1=k.PHIc. F'c^0.5 *hef^1.5* R= 427357.6 Nt <Nbr2 D-7 10 casi in headed studs, headed
k= 10 from table 7 post installed anchors
Nbr2=3.9 PHIc. F'c^0.5. hef^(5/3).R= 469239.1 Nt D-8

Nbr=min(Nbr1,Nbr2)= 427357.6 Nt
ac= 3450 mm projected concrete failure area width
bc= 7000 mm projected concrete failure area length
AN=ac.bc= 24150000 mm2
D.6.2.7
Psicp,n
Cac=2.5 hef= 1245 mm D.9.7.

Camin= min(C1,C2)= 440 mm

Camin= 440 mm
Psicp,n =1 IF Camin>=Cac D-13 1 Cac= 1245 mm
2 1.5hef= 747 mm
Psicp,n = max(Camin/Cac, 1.5hef/Cac) IF Camin<C D-14 3 Camin/Cac 0.353414
4 1.5hef/Cac 0.6
Psicp,n= 0.6 Max3,4 0.6
Psic,n= 1

Psied,n = 1 IF Cmin>1.5hef D-11


PsIed,n = 0.7+0.3(Cmin/1.5hef) IF Cmin<1.5hef D-12

PHIed,n= 0.88
D-5
Ncbr=(An/Ano)*(Psied,n. Psic,n.Psicp,n). Nbr= 2432277 Nt 2432 Kn >
D.6.2.8 WHEN AN ADDITIONAL PLATE IS ADDED AT THE HEAD OF THE ANCHOR
t= 50 mm
Ano2=(2(Dp/2+t+1.5Hef))^ 2768896 mm2 MODIFY THE PROJECTED AREA OF THE FAILURE

Ncbr= 1960683.63118 Nt 1961 Kn > 1200 ok

D.6.3 PULLOUT RESISTANCE OF ANCHOR IN TENSION


Ncpr=Psic,p. Npr D-15
Psic,p= 1 1.4 no cracking at service load otherwist 1.0D.6.3.6
Npr=8 Abh. PHIc. F'c. R= 233432 Nt
Abh=3.14(Dp^2-d^2)/4= 1283 mm2
Ncpr=Psic,p. Npr= 233 kn < 1200 not ok
WHEN AN ADDITIONAL PLATE IS ADDED AT THE HEAD OF THE ANCHOR
Abhm=((Dp+2t)^2-d^2))/4= 20122.59 mm2
Ncprm=Ncpr.Abhm/Abh= 3662.312 kn > 1200 ok

D.6.4. CONCRETE SIDE FACE BLOWOUT/HEADED ANCHOR IN TENSION

Cmin= 440 mm
0.4hef= 199.2
c1= 440 maxc1,c2= 747
c2= 747 minc1,c2= 440
s1= 781 mins1,s2= 781
s2= 781
R= 1 A= (1+max(C1,C2)/(min(C1,C2))/4= 0.674432
B= (1+min(s1,s2)/(6.min(c1,c2))/2= 0.647917

C= min(1,A)= 0.674432

redc=max(0.5,c)= 0.674432 minredc,s=0.647917


res=min(1,B)= 0.647917
Landa= 1
Nsbr=min(redc,reds)*13.3*min(c1,c2)*(Abh)^0.5. PHIc.Landa.fic^0.5*R 522 kn <
WHEN AN ADDITIONAL PLATE IS ADDED AT THE HEAD OF THE ANCHOR
Abhm=((D+2t)^2-d^2))/4= 20122.59 mm2 Abhm=odified Abh
Nsbr=Nsbr*(Abhm/Abh)^0. 2068.297 kn Nsbr= 2068.297 kn >
KN

c=

Ld

Ld

Nst(kn)
1050
918
1509
1312

293
498
260
260

casi in headed studs, headed bolts, hooked bolts


post installed anchors

1200 OK
1200 not ok

1200 ok